comply with applicable
federal, state, and local plumbing/
electrical codes having jurisdiction.
CAUTION: Follow this
setup procedure before
attempting to use this
unit. Failure to follow these instructions can result in injury and/or void
of warranty.
CAUTION: DO NOT
connect the unit to hot
water. The inlet valve is
not rated for hot water.
IMPORTANT:
After setup, run a FULL
brewcycle. Place a tea
container to catch both hot water
from the brewcone and dilution water
from spout on the front cover.
WARNING HOT LIQUID,
Scalding may occur.
Avoid splashing.
ISO 9001:2008 REGISTERED
Wilbur Curtis Company, inC.
Service Manual – TCT & PTT
Important Safeguards/Symbols
This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance should be performed by an
authorized Wilbur Curtis service technician.
• Do NOT immerse the unit in water or any other liquid
• To reduce the risk of re or electric shock, do NOT open service panels. No user serviceable parts inside.
• Keep hands and other items away from hot surfaces of unit during operation.
• Never clean with scouring powders, bleach or harsh chemicals.
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
The Curtis G3 Brewer is Factory Pre-Set and Ready to Go… Right from the Box.
Following are the Factory Settings for the G3 Iced Tea Brewer.
• Brew Temperature = 204°F
• Brew Volume = Set to dispensing vessel requirements (2.2 liters)
Generally there will never be a reason to change the G3/Gold Cup Series default settings. However, should you need to make slight
adjustments to meet your brewing needs, programming instructions are provided later in this manual.
System Requirements:
• Water Source 20 – 90 PSI. Minimum ow rate of ½ gpm (1 gpm preferred ow rate).
• Electrical: See electrical schematic on page 6.
SETUP STEPS
The unit should be level (left to right and front to back), and located on a secure counter top. Connect a water line from the water lter to
the brewer.
NOTE: A water ltration device must be used to maintain a trouble-free operation. (In areas with extremely hard water, we suggest
that a sedimentary and taste & odor lter be installed.) This will prolong the life of your brewing system and enhance coffee quality.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for
cleaning underneath.
2. In some areas an approved backow prevention device may be required between the brewer and the water supply.
3. Water pipe connections and xtures directly connected to a potable water supply shall be sized,
installed and maintained in accordance with federal, state, and local codes.
1. A 1/4” Flare has been supplied for water line connection. Use tubing sized sufciently to provide ½ GPM (preferred ow rate is 1gpm).
2. Connect the unit to an appropriate electrical power circuit.
3. Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to ll. When the water level in the tank rises
to the correct volume, the heating element will energize automatically. With G3 tea brewers there is no danger of element burnout
caused by an empty tank.
4. The heating tank will require 20 to 30 minutes to reach operating temperature (204°F) as indicated by the READY-TO-BREW LCD
readout.
5. Important: Run one full brewcycle, to purge the water lines and valves of air. Five seconds of dilution water at the beginning of each
brewcycle is normal pre-programmed operating behavior.
BREWING INSTRUCTIONS
1. Brewer should be ON (Conrm at rear toggle switch, then press ON/OFF button) and Ready-to-Brew displayed.
2. Place lter in brew basket.
Pour leaf tea into basket.
3. Slide brew cone into brew
rails. Place tea container
under brew cone.
4. Press the BREW button to
brew tea.
WILBUR CURTIS CO.
Montebello, CA 90640
For the latest information go to
www.wilburcurtis.com
Tel: 800/421-6150
1
Programming
Your Curtis Generation 3 Brewer is Factory Pre-Set for Optimum Performance.
After connection to water and power; the rear toggle switch must be on. You will hear a beep sound, indicating power is available to the controller.
CURTIS
HEATING
CURTIS
FILLING
GRAY
The control displays . Press ON/OFF button and the screen will display . After three seconds, is displayed.
Water will ll the tank (approximately 2-3 minutes depending on water ow rate). When the proper level is reached will appear on the
screen. It takes approximately 20 minutes to reach set point temperature of 204°F.
Control will display when temperature reaches the set point (204°F). Unit is now ready to brew.
CURTIS< TCT >
CURTIS
READY to BREW
CURTIS
To Go Into Programming
Turn off (dark display) by pressing ON/OFF button (yellow). Press and hold BREW button 4 (green) and then press and release ON/OFF button (yellow).
Continue holding BREW button. Display will read , wait until is displayed Enter the 4-digit access code, the digits 1-4 correspond to the buttons (see illustration below).
The default code set at the factory is 1-2-3-4. Then will be displayed.
All programming selections are performed with the three center buttons.
The symbols below the buttons are:
Scroll LEFT
312
4
SELECTION or ENTER to save new parameter
Scroll RIGHT
SPRAYHEADS: Mentioned in this Programming guide are the words Gray and Purple. This refers to the color of the sprayhead. The current
sprayhead is the purple AFS. The older version is the gray sprayhead. See the illustration at right.
Program Menus
Program Menus
Recipes
Tea By Volume
Tea By Time
Tea Dilut Delay
Tea Dilut Volume
PURPLE
Program Menus screen. Press > button, to show the next menu item.
Recipes (Factory set to Standard Tea Purple)
Press to Select. Press < or > to scroll through recipes: Standard Gray, Standard Purple, Tropical Gray, Tropical
Purple, 76/308 Gray or 76/308 Purple. Press to set.
Tea by Volume: Press to select, Display will now show Push START To Begin... Press the BREW button then
hot water starts running, when desired volume is reached press BREW button again to stop the ow. Now the
*
volume has been set. Pressing > button will display the subsequent menu features.
Tea by Time (Factory set to 5:52)
*
Press to select. By pressing < or > buttons, you can increase and decrease time. Press to set minutes and
seconds. Units with the half batch option, the Half Batch brew button is factory set at for half the brew time (2:56).
Tea Dilution Delay (Factory set to 0:30)
*
Press to Select. Press < or > buttons, to add or decrease time. Press to set.
Tea Dilution Volume: Press to Select, Display will now show Push START To Begin... Press the BREW button
and water will ow, when desired volume is reached press BREW button again to stop the ow. Now the volume
*
has been set. Press > to display subsequent menu features.
2
Tea Dilut Time
Dilution Time (Factory set to 4:05)
*
Press to Select. By pressing < or > buttons, you can increase and decrease time. Press to set minutes and
seconds.
* On units with the half batch option, the half batch brew button may be independently set.
Continued on Page 3
Programming
Tea Dilut Stir
Tea Pulse Brew
Tea Fast Brew
Tea Half Batch
Tea Drip-Out
Temperature
Energy Save Mode
Tea Dilution Stir (Factory set to ON).
Press to Select. Press < or > buttons, to toggle between OFF and ON. Press to set.
Tea Pulse Brew (Factory set to OFF).
Press to Select. Press < or > to select ON, OFF or D. D is a manual adjust from 1 to 20 pulses with an ON time
from 5 to 150 seconds and an OFF time from 5 to 150 seconds.
Tea Fast Brew (Factory set to OFF).
Press to Select, press < or > to choose ON or OFF. Selecting ON will start hot water spraying in the brewcone rst
and then 1 minute later the dilution water will start to ow.
Tea Half Batch (Factory set to OFF).
Press to Select. Press < or > buttons, to toggle between OFF and ON. Press to set.
Tea Drip-Out (Factory set to OFF)
Press to Select. Press < or > to adjust time. Settings are OFF, up to 15 minutes, at one minute increments.
Temperature (Factory set to 204ºF)
Press to Select. Press < or > to increase or decrease setting. Temperature range, from 170ºF to 208ºF in 2-degree
increments.
Energy Save Mode (Factory set to OFF)
Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from
last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank during periods of non-operation.
Brew Count Odom
Brew Count Total
Cold Brew Lock
Master Reset
Service Call
Access Code
Brew Count Odom.
Press to Select, Shows total gallons and total brew cycles on the unit. Press ex or Reset Brew Count Total.
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Cold Brew Lock (Factory set to 5º F)
Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The rst setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of
set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selections in the UCM return to factory defaults.
Service Call (Phone number Factory set to 1-800-000-0000)
Press to display number and change number or < to move place and EX to exit when complete. This number will
be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Continued on Page 4
3
Programming
Banner Name
P-Maintenance
Beeper On/Off
Quality Timer
Display Brew
Time
Display Messages
Model Select
Banner Name (Factory set to CURTIS)
Press to display letters and change letters or < to move place and EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks
disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
P-Maintenance (Factory set to OFF)
Press to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.
Press to exit.
Beeper On/Off (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature
allows you to hear a short beep each time a button is pressed.
Quality Timer (Factory set to OFF)
Press to Select. By pressing < or > buttons, you can increase and decrease time. Setting range is from 0 to 10
hours in 1 hour increments. Press to set. Expired time indicated by audio alarm and ashing “Quality Timer”.
Display Brew Time (Factory set to ON)
Press to Select. Pressing < or > toggles between ON and OFF.
Display Messages (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. This feature allows the operator to
select the message “Rinse Server Before Brewing”. This will be displayed any time the unit is not brewing.
Model Select (Factory set to 1/Half Batch)
Press to Select. Pressing < or > toggles between 1/Half Batch and 3-Batch.
Exit
Exit
Press to select, exits program mode and returns unit to operation. Pressing > returns you to Tea Recipes.
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold button (see illustration, page 2) for 5 seconds. Water Temperature
will be displayed (temperature in heating tank).
Error Message
With G3/Gold Cup Series brewers, there are three error messages that can appear on the screen to advise the user of a malfunction. If one of
these error messages appear, the brewer will lock up and stop functioning until the error is corrected.
An error message will occur under the following conditions:
(800) 000-000
Water Level Err
(800) 000-000
Sensor Err
1. Water level ll error or overow. This error message occurs when the inlet valve solenoid has been on for more than
10 minutes. This error message also occurs when the valve is relling the tank during a brew cycle for more than 1½
minutes.
2. Water temperature control system error. An open probe or a break in the temperature control circuit is detected.
The screen may display a phone number to call for service. After the malfunction is corrected, the error message must be
cleared. To reset the control panel and return to normal operation, press for 5 seconds.
4
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.