Wieland SNA 4063K, SNA 4063KM, SNA 4064K, SNA 4064KM Catalog Page

SNA 4063K/KM, SNA 4064K/KM
MONITORING OF EMERGENCY STOP, SAFETY GATES AND LIGHT BARRIERS
APPLICATIONS
• Monitoring of emergency stop applications
• Monitoring of safety gates
• Monitoring of light barriers
• Up to PL e / Category 4 (EN ISO 13849-1)
• Up to SIL
FEATURES
• Stop Category 0 according to EN 60204-1
• Single-channel or two-channel control
• Manual reset with monitoring
• Cross monitoring
• 3 to 4 enabling current paths
] Y t L
3 (EN 62061)
CL
FUNCTION
After the supply voltage is applied to terminals A1/A2 and the safety inputs are closed, the enabling current paths (NO contacts) are closed and the signal current path (NC contact) is opened by pressing the reset button (manual start with monitoring). When the safety inputs are opened/de-energized, the enabling current paths (NO contacts) are opened immediately.
CIRCUIT DIAGRAM
Manual start with monitoring – Reset input S34 is connected to safety input S11 via a RESET button. To monitor external contact blocks (EDM), their NC contacts must be connected in series to the RESET button.
Monitoring of light curtains – The KM device types are espe­cially suitable for the monitoring of very fast tactile switching operations, for example in safety light curtain applications. Very short switch-off procedures of a few milliseconds are detected reliably and lead to the switching off of the internal relays.
SNA 4064K/KMSNA 4063K/KM
.
46
safe RE LAY
OVERVIEW OF DEVICES | PART NUMBERS
Typ e Rated voltage Terminal s Part no. P.U .
SNA 4063K-A 24 V AC/DC R1.188.1440.0 1 SNA 4063K-A 115-120 V AC R1.188.1450.0 1 SNA 4063K-A 230 V AC R1.188.1460.0 1 SNA 4063K-C 24 V AC/DC R1.188.1950.0 1 SNA 4063KM-A 24 V AC/DC R1.188.3290.0 1 SNA 4063KM-C 24 V AC/DC R1.188.3420.0 1 SNA 406 4K-A 24 V AC/DC R1.188.1900.0 1 SNA 406 4K-A 115-120 V AC R1.188.1920.0 1 SNA 406 4K-A 230 V AC R1.188.1930.0 1 SNA 406 4K-C 24 V AC/DC R1.188.1970.0 1 SNA 4064KM-A 24 V AC/DC R1.188.3360.0 1 SNA 4064KM-C 24 V AC/DC R1.188.3430.0 1
TECHNICAL DATA
Function Emergency stop relay Function display 3 LEDs, green
Power supply circuit
Rated voltage U
N
A1, A2 24 V AC/DC / 115-120 V AC / 230 V AC
Rated consumption 24V DC / 24 V AC 1.6 W / 2.9 VA
42-48V AC / 115 -120V AC / 230 V AC 2.3 W / 2.6 VA Rated frequency 50 - 60 Hz Operating voltage range U
B
Electrical isolation supply circuit - control circuit yes (at UN = 115-230 V AC, 230 V AC)
Control circuit
Rated output voltage S11/S21 24 V DC Input current / peak current S12, S52/S22 | S34 25 mA / 100 mA | 5 mA / 50 mA Response time t Minimum ON time t Recover y time t Release time t Synchronous time t Permissable test pulse time t Max. resistivity, per channel
Output circuit
/ t
A1
A2
M
W
R
S
TP
1)
SNA 4063K/KM SNA 406 4K/KM Enabling paths 13/14, 23/24, 33/34 13/14, 23/24, 33/34, 43/44 normally open contact Signaling paths 41/42 --- normally closed contact Contact assignment forcebly guided Contact type Ag-alloy, gold-plated Rated switching voltage enabling / signaling path 230 V AC Max. thermal current I
th
enabling / signaling path 8 A / 5 A Max. total current I² of all current path (Tu = 55 ºC) / (Tu = 65 ºC) 25 A² / 9 A² Application category (NO) AC-15 | DC-1 3 U Short-circuit protection (NO), lead fuse / circuit breaker 6 A class gG / melting integral < 100 A²s Mechanical life 10
General data
Creepage distances and clearances between the circuits EN 60 664 -1 Protection degree according to EN 60529 (housing / terminals) IP40 / IP20 Ambient temperature / storage temperature -25 ºC - +65 º C / -25 ºC - + 75 ºC Wire ranges screw terminals, fine-stranded / solid 1 x 0.2 mm² – 2.5 mm² / 2 x 0.2 mm² – 1.0 mm²
fine-stranded with ferrules 1 x 0.25 mm² – 2.5 mm² / 2 x 0.25 mm² – 1.0 mm² Permissible torque 0-5 - 0-6 Nm Wire ranges push-in terminals 1 x 0-25 mm² bis 1-5 mm² Weight 24 V AC/DC device / AC device 0-21 kg / 0-25 kg Standards EN ISO 13849-1, EN 62061, EN 81-20/50, EN 50156-1, EN 61511 Approvals TÜV, cULus, CCC, GL
1)
If two-channel devices are installed as single channel, the value is halved.
Screw terminals, pluggable Screw terminals, pluggable Screw terminals, pluggable Push-in terminals, pluggable Screw terminals, pluggable Push-in terminals, pluggable Screw terminals, pluggable Screw terminals, pluggable Screw terminals, pluggable Push-in terminals, pluggable Screw terminals, pluggable Push-in terminals, pluggable
0.85 - 1.1 x U
N
100 ms / --­100 ms 750 ms 10 ms no
< 1 ms 24V AC/DC ≤ (5 + (1,176 x UB / UN - 1) x 100) Ω 42-48V AC/ 115-120 V AC, 230 V AC
≤ (5 + (1,176 x UB / UN - 1) x 100) Ω
230 V, Ie 3 A | Ue 24 V, Ie 3 A
e
7
switching cycles
safe REL AY
safe RE LAY
.
47
Loading...