White Rodgers F61 User Manual

Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
This adaptor plate assembly is designed for mounting a Comfort-Set 70 series thermostat to the wall or to a junction box. The wall cover plate covers the junction box, wall damage, or old thermostat markings. The adaptor plate is designed to allow horizontal thermostat mounting, regardless of junction box orientation.
F61 Series
Adaptor Plate Assembly
INSTALLATION INSTRUCTIONS
DESCRIPTION
Adaptor Plate
All kits may not have adaptor plate or all screws shown.
CAUTION
!
To prevent electrical shock and/or equip­ment damage, disconnect electrical power at main fuse or circuit breaker until installa­tion is complete.
CONTENTS
Description ........................................................ 1
Precautions ....................................................... 1
Installation ......................................................... 2
No. 6 X 5/16” Phillips
pan-head screw (2)
F61-2510 Wall Plate
6-32 X 3/4” flat-head
machine screw (4)
PRECAUTIONS
NOTE
This instruction sheet is not intended as a wiring guide. Refer to the thermostat installation instructions to ensure proper wiring.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
Printed in U.S.A.
PART NO. 37-6408A
0223
INSTALLATION
No. 6 X 5/16” Phillips
pan-head screw (2)
FOR 1F7X DIGITAL THERMOSTATS
3
6-32 X
flat-head
/
4
machine screws
F61-2510 Wall Plate
Subbase
Junction Box
No. 6 X 5/16” Phillips
pan-head screw (2)
1F7X Thermostat
Figure 1. Mounting 1F7X digital thermostat to horizontal junction box.
Locate and drill two clearance holes in wall
3
3
6-32 X
flat-head
/
4
machine screws
6-32 X
flat-head
/
4
machine screws
Adaptor Plate
F61-2510 Wall Plate
Junction Box
Subbase
1F7X Thermostat
Figure 2. Mounting 1F7X digital thermostat to vertical junction box.