REMOTE FAN MOTOR - INLINE UnIT
Product Features
Motor Mounting Inline - Through Wall or Eave
Extraction Levels
Available
Finish
Ducting 200mm Acoustic (PVC Coated) Flexi Ducting
Duct Clamps Dia. 200mm (Stainless Steel) - 4X Units Supplied
Vent Dia. 220mm Aluminium with ne mesh liner and
Fan Power Supply Cable Length: Three (3) Metres
Sound Pressure Level IL.800: 52dB(A)* when operating at ‘Boost’ speed
Model: IL.800
Lite - 800 m3/hr
Model:
IP.1140
Pro - 1140 m3/hr
High Grade FR ABS Plastic
Colour: Shale Grey
Five (5) Metre Length Supplied
Powder Coat Finish - Colour: White - 1X Unit Supplied
IP.1140: 58dB(A)* when operating at ‘Boost’ speed
* Outside Level @ 1M & System Pressure 50pa
(222 L/s @ 50pa)
(317 L/s @ 50pa)
Inline Motor Unit
External View
Inlet Cone &
Flow Grid
Dimensioned Drawings
390
200
159
70
314
Inline Motor Unit
363.5
30
12
143.5 125
268.5
Inline Motor Unit
Internal View
Haus Group Australia Pty Ltd - 03 8593 9600 - www.whispair.com.au
REMOTE FAN MOTOR - INLINE Unit
Performance Charts
780
LEGEND
700
600
500
400
Pressure Increase [Pa]
300
Lite Pro
Lite: EBM-papst R2E220-RA38-01 fan as used in Whispair Lite 800
Pro: EBM-papst R2E225-RA92-09 fan as used in Whispair Pro 1140
Please Note: 1 mtr of duct = 20pa
Quoted
800
1140
@ 0pa
885
1175
@ 50pa
800
1140
@ 125pa
655
1040
@ 200pa
440
915
200
100
0
Installation Schematics
INLINE KLEENAIR
FAN MOTOR SOLUTION
Vented through Eave
60050040030020010 00
Volumetric Flow [m3/hr]
Expected pressure range
for cooker hoods with ducting
700 800 900 1000 1100 1200
Ducting Pulled Tight
200mm Ducting
Attached to Internal Hood Unit Outlet
Gentle Bend In Ducting
Fan Power Supply
Attached to Internal Hood Unit
Vent & Eave
Roof
INLINE KLEENAIR
FAN MOTOR SOLUTION
Vented through Wall
Wall
Fan Power Supply
Attached to Internal Hood Unit
Gentle Bend In Ducting
Ducting Pulled Tight
200mm Ducting
Attached to Internal
Hood Unit Outlet
Vent