Whirlpool YWMH75021HZ2, YWMH75021HV2 Installation Guide

MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See the “Installation Requirements” section for further notes.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the illustration in these installation instructions.
INSTRUCTIONS D’INSTALLATION
DE L’ENSEMBLE FOUR À MICRO-ONDES/HOTTE
Ce produit est conçu pour l’utilisation au-dessus d’appareils de cuisson électriques ou à gaz de 36" (91,4 cm) de largeur ou moins. Voir la section “Exigences d’installation” pour d’autres remarques.
Ces instructions d’installation sont valables pour plusieurs modèles. Il se peut que l’apparence de votre propre modèle soit légèrement différente de celle montrée sur les illustrations dans ce document.
Table of Contents/Table des matières
MICROWAVE HOOD COMBINATION SAFETY ..................................1
INSTALLATION REQUIREMENTS
Tools and Parts Remove Cardboard Template Location Requirements
Product Dimensions...........................................................................3
Electrical Requirements
INSTALLATION INSTRUCTIONS
Remove Mounting Plate Rotate Blower Motor Locate Wall Stud(s) Mark Rear Wall Drill Holes in Rear Wall Attach Mounting Plate to Wall Prepare Upper Cabinet Install Damper Assembly Install the Microwave Oven Complete Installation
VENTING DESIGN SPECIFICATIONS ASSISTANCE
Replacement Parts Accessories
..................................................................................2
......................................................................2
..................................................................... 3
....................................................................4
..........................................................................4
............................................................................ 6
................................................................................... 7
....................................................................... 8
...................................................................... 9
....................................................................... 11
......................................................................................13
..........................................................................13
...................................................................................... 13
.......................................................2
............................................................2
.........................................................4
........................................................... 8
................................................................... 9
..............................................................10
............................................... 12
SÉCURITÉ DE L’ENSEMBLE FOUR À MICRO-ONDES/HOTTE EXIGENCES D’INSTALLATION
Outillage et pièces Dépose du gabarit de carton Exigences d’emplacement Dimensions du produit Spécifications électrique
INSTRUCTIONS D’INSTALLATION
Dépose de la plaque de montage Réorientation du moteur du ventilateur Identifier la position du/des poteau(x) du colombage mura Tracé sur le mur arrière Perçage de trous dans le mur arrière Fixation de la plaque de montage sur le mur Préparation du placard supérieur Installation du module du clapet anti-reflu
Installation du four à micro-ondes ................................................... 24
Achever l’installation
SPÉCIFICATIONS/CONCEPTION DU CIRCUIT D’ÉVACUATION ASSISTANCE
Pièces de rechange Accessoires
...........................................................................15
........................................................................ 25
......................................................................................27
.........................................................................27
...................................................................................... 27
.........................................................15
........................................................... 16
..............................................................16
.....................................................................16
................................................................ 17
................................................... 17
...................................................17
........................................... 17
...........20
.................................................................... 21
.............................................. 22
.................................. 22
.................................................... 23
.................................... 23
....15
.. 26
MICROWAVE HOOD COMBINATION SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
follow instructions.
You instructions.
W
11199603B
can be killed or seriously injured if you don't
follow
INSTALLATION REQUIREMENTS
Tools and Parts
Tools Needed
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Measuring tape Pencil Masking tape or
thumbtacks
Scissors No. 2 Phillips screwdriver No. 3 Phillips screwdriver
for ¹⁄₄ - 20 x 3" (7.62 cm) bolts
Drill
³⁄₁₆" (5 mm), ³⁄₈" (10 mm),
⁵⁄₈" (16 mm) drill bits
³⁄₄" (19 mm) hole saw
Parts Supplied
For information on reordering, see the “Replacement Parts” section.
NOTE: The hardware items listed here are for wood studs. For other types of wall structures, be sure to use appropriate fasteners.
A
A. ³⁄₁₆
-24 x 3" (7.62 cm) round-head
bolts (2)
¹⁄₄ daeh-talf )mc 26.7( "3 x 02-
B.
bolts (2) C. Washers (2) D.
³⁄₁₆" (5 mm) toggle nuts (2)
E.
¹⁄₄ )mc 80.5 x mm 53.6( "2 x "
lag screws (2) F.
6 x 3/8 "# G. H.
roof venting)
B
C
H
(2)
swercs latem teehS
)1( gnihsub droc ylppus rewoP
r o llaw rof( ylbmessa repmaD
Diagonal wire cutting pliers Stud finder ⁷⁄₁₆" (11.11 mm) socket
wrench (or box wrench) for ¹⁄₄" x 2" (6.35 mm x
5.08 cm) lag screws 1½" (3.8 cm) diam. hole
drill bit for wood or metal cabinet
Keyhole saw Caulking gun and
weatherproof caulking compound
Duct tape
D E F
Not Shown:
Upper cabinet template Mounting plate (attached to
back of microwave oven) Cardboard template (part of
packaging) or wall template Aluminum grease filters Charcoal filters (Depending on
model, charcoal filters may not be included. See User Instructions.)
G
Remove Cardboard Template
The cardboard piece from the top of t he microwave oven packaging is perforated. The piece inside the perforation is for use as a rear wall template.
1. Cut along the perforation to separate the template from the rest of the cardboard packaging.
2. Set the cardboard template to the side and refer to it during
the “Mark Rear Wall” part of installation.
Depending on your model, skip "Remove Cardboard Template" steps if full carton box is used for packing. But use the wall template for "Mark Rear Wall" part of the installation.
Location Requirements
Check the opening where the microwave oven will be installed. The location must provide:
Minimum installation dimensions. See the “Installation
Dimensions” illustration.
Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and
minimum ³⁄₈" (10 mm) thickness drywall or plaster/lath within cabinet opening.
Support for weight of 150 lbs (68 kg) which includes
microwave oven and items placed inside the microwave oven and upper cabinet.
Grounded electrical outlet inside upper cabinet. See the
“Electrical Requirements” section.
NOTES:
If ins talling the microwave oven near a left sidewall, make su re there is at least 6" (15.2 cm) of clearance between the wall and the microwave oven so that the door can open fully.
emo S models have a pocket handle. If installing the microwave nea r a right side wall, make sure there is at least 3 inches of clearance between wall and microwave oven so you can grab the handle integrated inside the door.
S ome cabinet and building materials are not designed to withstand the heat pro cooking. Check with your builder or cabinet supplier to make sure that the materials used will not discolor , delaminate, or sustain other damages.
Special Requirements
For Wall Venting Installation Only:
Cutout must be free of any obstructions so that the vent fit
properly and the damper blade opens freely and fully.
For Roof Venting Installation Only:
If you are using a rectangular-to-round transition piece,
the 3" (7.6 cm) clearance needs to exist above the microwave oven so that the damper blade can open freely and fu lly. See “Rectangular to Round Transition” illustration in the “Venting Design Specifications” section .
duced by the microwave oven for
NOTE: Depending on model, aluminum grease filter and charcoal filter may be combined
Materials Needed
Standard fittings for wall or oof venting. See the “Venting
Design Specifications” section
2
Installation Dimensions
A B
NOTE: The grounded 3 prong outlet must be inside the upper cabinet. See the “Electrical Requirements” section.
12" (30.5 cm) min. 14" (35.6 cm) max. upper cabinet and
side cabinet depth
66" (167.6 cm) min.
30"
(76.2 cm)
min.
(76.2 cm)
30"
typical*
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
Observe all governing codes and ordinances.
Required:
A 120 V, 60 Hz, AC only, 15 or 20 A electrical supply
with a fuse or circuit breaker
Recommended:
■ A time-delay fuse or time-delay circuit breaker
■ A separate circuit serving only this microwave oven
A. 2" x 4" (5.08 x 10.16) wall stud B. Grounded 3 prong outlet
*30” (76.2 cm) is typical for 66” (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/ cooktop below.
NOTE: To ensur e good performance, do not obstruct top vent airflow. If cabinets are deeper than 14” (35.6 cm) but no mor e than 15” (38.1cm), use the bump out mounting kit r ee pplacing the I bar mounting plate fr om the wall. The bump out mounting kit (part # W11185746) is not provided but can be purchased from Whirlpool.
DEEPER
12"
I bar mounting plate
14"
DEEPER
14"
Bump out mounting bracket
15"
Product Dimensions
"
¹⁄₈
17
(43.5 cm)
"
³⁄₁₆
+/­(0.5 cm)
16¹⁄₄"
(41.3 cm)
GROUNDING INSTRUCTIONS
For all cord connected appliances:
The microwave oven must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. The microwave oven is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualified electrician or serviceman install an outlet near the microwave oven.
SAVE THESE INSTRUCTIONS
Up to
16
(42.5 cm)*
³⁄
"
29
⁷⁄₈
" (76.0
cm)
*Overall depth of product will vary slightly depending on
door design.
3
INSTALLATION INSTRUCTIONS
A
B
A
A
Remove Mounting Plate
Depending on your model, the mounting plate may be in the foam packaging, or it may be attached to the back of the microwave oven.
NOTE: To avoid possible damage, cover the work surface.
1. Remove any remaining contents from the microwave
oven cavity.
2. If the mounting plate is attached to the back of the microwave
oven, remove it and set it aside.
3. Tape the microwave oven door closed so that the door does
not swing open while the microwave oven is being handled.
NOTE: To avoid damage to the microwave oven, do not grip or use the door or door handle while the microwave oven is being handled.
Rotate Blower Motor
The microwave oven is set for recirculation installation. For wall or roof venting, changes must be made to the venting system.
NOTE: Skip this section if you are using recirculation installation. Keep the damper assembly in case the venting method is changed, or the microwave oven is reinstalled in another location where wall or roof venting may be used.
Wall Venting Installation Only
1. Remove screws attaching damper plate to top of microwave
oven exterior. Slide damper plate toward the front of the microwave oven and lift up.
4. Lift blower motor out of microwave oven.
A. Blower motor
5. Rotate blower motor 180° so that exhaust ports face the back
of microwave oven, and lower blower motor back into the microwave oven.
A. Exhaust port
6. Using diagonal wire cutting pliers, gently snip out the
rectangular damper vent covers at the perforations.
A. Screws B. Damper plate
2. Keep damper plate and screws together and set aside.
3. Remove 2 screws attaching blower motor to back
of microwave oven.
A
A. Screws (in recessed holes)
4
A
B
A. Diagonal wire cutting pliers B. Damper vent covers
7. Reattach blower motor to back of microwave oven
D
B
C
D
B
with the 2 screws removed in Step 3.
8. Reattach damper plate. Make sure damper plate tabs are
inserted into the slots in the top of the microwave oven.
6. Using diagonal wire cutting pliers, gently snip out the
rectangular vent covers on the damper plate removed in Step 1 at the perforations.
A
A. Damper plate B. Screws C. Damper plate tabs D. Slots
B
C
9. Secure damper plate with 2 screws removed in Step 1.
Roof Venting Installation Only
1. R
epeat Step 1 from “Wall Venting Installation Only.”
2. Repeat Step 2 from “Wall Venting Installation Only.”
3. Repeat Step 3 from “Wall Venting Installation Only.”
4. Repeat Step 4 from “Wall Venting Installation Only.”
5. Rotate blower motor so that exhaust ports face the top of
microwave oven, and flat sides of blower motor face back of microwave oven. Lower blower motor back into microwave oven.
A
A. Diagonal wire cutting pliers B. Rectangular vent covers
7. Reattach blower motor to back of microwave oven with 2
screws removed in Step 3 of “Wall Venting Installation Only.” Securely tighten screws.
NOTE: If blower motor is not correctly oriented, the 2 screws removed in Step 3 cannot be reattached to the microwave oven.
8. Reattach damper plate. Make sure damper plate tabs are
inserted into the slots in the top of the microwave oven.
A
A
A. Exhaust port
IMPORTANT: If blower motor is not positioned with flat side facing the back of the microwave oven (as shown), performance will be poor.
A. Damper plate B. Screws C. Damper plate tabs D. Slots
9. Secure damper plate with 2 screws removed in Step 1
of “Wall Venting Installation Only.”
5
Loading...
+ 10 hidden pages