Whirlpool WHADUS5 Installation And Operation Manual

Model WHADUS5
How to install, operate
and maintain your
Dual Stage
Do not return unit to store
If you have any questions or concerns when
installing, operating or maintaining your water
filtration system, call our toll free number:
1-866-986-3223
Monday- Friday, 7 AM - 6 PM CST or visit
whirlpoolwatersolutions.com
When you call, please be prepared to provide
the model number and date code of your
product, found on the rating decal on back.
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction
of chlorine taste and odor, and Standard 53 for
the reduction of cysts, lead, MTBE and VOCs.
Manufactured and warranted by
Ecodyne Water Systems
1890 Woodlane Drive Woodbury, MN 55125
Installation and Operation Manual
201-8402712 (Rev. 02 7/11/16)
TABLE OF CONTENTS
Page
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Performance Claims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
efore You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
B
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Parts of the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Materials & Tools Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Undersink Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
Step A - Install Cold Water Supply Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step B - Make Hole for Filtered Water Faucet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step C - Install Faucet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Step D - Make Tubing Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Step E - Turn On Water, Check for Leaks and Rinse Carbon Fines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Filter Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Filter Cartridge Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Filter Cartridge Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Faucet Electronics & Battery Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Troubleshooting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
WARRANTY
ONE YEAR LIMITED WARRANTY ON DUAL STAGE WATER FILTRATION SYSTEM
(except filter cartridges)
Warrantor: Ecodyne Water Systems, 1890 Woodlane Drive, Woodbury, MN 55125
Warrantor guarantees, to the original owner, that the Water Filtration System, when installed and maintained in accordance with the instructions, will be free from defects in materials and workmanship for a period of one (1) year from the date of purchase. If, within the first year, a part proves, after inspection, to be defective, Warrantor will, at its sole option, either replace or repair the part without charge except normal shipping and installation charges. Labor to maintain the equipment is not part of the warranty. Filters, which are expendable, are not covered by the warranty.
TO OBTAIN WARRANTY PARTS, SIMPLY CALL 1-866-986-3223, Monday - Friday, 7 am - 6 pm CST, for assistance. This warranty applies only while this product is in use in the United States or Canada.
General Provisions
The above warranties are effective provided the Water Filtration System is operated at water pressures not exceeding 125 psi, and at water temperatures not exceeding 100°F; provided further that the Water Filtration System is not subject to abuse, misuse, alteration, neglect, freezing, accident or negligence; and provided further that the Water Filtration System is not damaged as the result of any unusual force of nature such as, but not limited to, flood, hurricane, tornado or earth­quake. Warrantor is excused if failure to perform its warranty obligations is the result of strikes, government regulation, materials shortages, or other circumstances beyond its control.
*THERE ARE NO WARRANTIES ON THE WATER FILTRATION SYSTEM BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED TO THE EXTENT THEY MIGHT EXTEND BEYOND THE ABOVE PERIODS. THE SOLE OBLIGATION OF WARRANTOR UNDER THESE WARRANTIES IS TO REPLACE OR REPAIR THE COMPONENT OR PART WHICH PROVES TO BE DEFECTIVE WITHIN THE SPECIFIED TIME PERIOD, AND WARRANTOR IS NOT LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. NO WAR­RANTOR DEALER, AGENT, REPRESENTATIVE, OR OTHER PERSON IS AUTHORIZED TO EXTEND OR EXPAND THE WARRANTIES EXPRESSLY DESCRIBED ABOVE.
Some states do not allow limitations on how long an implied warranty lasts or exclusions or limitations of incidental or con­sequential damage, so the limitations and exclusions in this warranty may not apply to you. This warranty gives you spe­cific legal rights, and you may have other rights which vary from state to state. This warranty applies to consumer-owned installations only.
Manufactured under license by Ecodyne Water Systems, Woodbury, Minnesota.
®/TM © 2015 Whirlpool. All rights reserved.
2
Specifications & Performance Claims
SPECIFICATIONS
upply Water Pressure Min. - Max.
S
Supply Water Temperature Min. - Max. 40 - 100 °F (4 - 38 °C)
Rated Service Flow 0.5 gallons per minute (1.89 liters per minute)
Filter Service Life 270 gallons (1,022 liters)
Inlet - Outlet 3/8" quick connect fittings
This system conforms to NSF/ANSI 42 and 53 for the specific performance claims as verified and substantiated by test data.
This filter improves the taste and odor and reduces many chemical contaminants in drinking water. The faucet indi­cator monitors the length of time the filter has been installed and will flash amber continuously, indicating the filters and battery need to be replaced.
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. The testing was performed using spiked tap water at a flow rate of 0.5 GPM (1.89 L/min.), pH of 7.5 ±0.5, pressure of 60 PSIG, and temperature of 68 ±5°F.
IMPORTANT NOTICE: Read this performance data and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water supply tested to determine your actual water treatment needs. This filter system is designed to be used for the reduction of the performance claims listed below. Do not use where water is microbiologically unsafe or of unknown quality, with­out adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfec­ted water that may contain filterable cysts. While testing was performed under standard laboratory conditions, actual performance of the system may vary based on local water conditions. Some or all of the contaminants reduced by this unit may not be in your water supply. See elsewhere in this manual for instructions on filter cartridge
replacement, system installation, operating procedures, and warranty. The maintenance instructions must be followed for the product to perform as indicated below.
NOTE: See labels on the water treatment system for additional information.
0 - 100 psi (207 - 689 kPa)
3
PERFORMANCE CLAIMS
Required
Contaminant
Influent
Level (mg/L)
Cyst ≥50,000 #/mL
Lead @ pH 6.5 0.15 ±10% 0.010 0.152 0.001 / 0.001 99.3 / 99.3 0.015
Lead @ pH 8.5 0.15 ±10% 0.010 0.150 0.001 / 0.001 99.3 / 99.3 0.015
Methyl tert-Butyl Ether (MTBE)
0.015 ±20% 0.005 0.01467 0.0005 / 0.0005 96.2 / 96.2 None
Substance
Chlorine Taste & Odor
VOC Reduction
p
2.0 ±10% 50%
Chloroform 0.30 ±10% 95%
j
Environmental Protection Agency maximum contaminant level as required under the Safe Drinking Water Act.
k
Milligrams per liter, which is equivalent to parts per million (PPM).
l
NSF minimum percent reduction requirement. Acceptance level for this substance is based on percent reduction, rather than maximum effluent concentration.
m
Particles per milliliter.
n
Microspheres was used as a surrogate.
o
The EPA has not determined a maximum contaminant level for this chemical.
p
Chloroform was used as a surrogate for the reduction of chemicals specified in the Organic Chemicals Reduced by Chloroform Surrogate Testing table (on the following page).
NSF Max. Per -
missible Effl.
k
Level (mg/L)
mn
99.95%
l
l
l
Average
k
Level (mg/L)
93,000 #/mL
Influent
Avg. / Max.
Effluent
k
Level (mg/L)
m
<1 /<4 #/mLm99.99 / 99.99 None
Avg. / Min.
k
Removal
Percent
EPAjMax.
Contaminant
Level (mg/L)
2.0 0.05 / 0.08 97.5 / 96.2 None
0.320 0.0005 / 0.0005 99.8 / 99.8 0.080
k
o
o
o
3
Performance Claims (continued)
ORGANIC CHEMICALS REDUCED BY CHLOROFORM SURROGATE TESTING
j
Contaminant
verage
A
Influent (µg/L)
k
aximum
M
Effluent
(µg/L)
Alachlor 50 1.0
trazine 100 3.0
A
Benzene 81 1.0
Carbofuran 190 1.0
Carbon Tetrachloride 78 1.8
Chlorobenzene 77 1.0
Chloropicrin 15 0.2
2,4-D 110 1.7
Dibromochloropropane (DBCP)
52 0.02
o-Dichlorobenzene 80 1.0
p-Dichlorobenzene 40 1.0
1,2-Dichloroethane 88 4.8
1,1-Dichloroethylene 83 1.0
cis-1,2­Dichloroethylene
trans-1,2­Dichloroethylene
170 0.5
86 1.0
1,2-Dichloropropane 80 1.0
cis-1,3­Dichloropropylene
79 1.0
Dinoseb 170 0.2
Endrin 53 0.59
Ethylbenzene 88 1.0
Ethylene Dibromide (EDB)
44 0.02
Haloacetonitriles (HAN):
Bromochloroacteonitrile
22 0.5
Dibromoacetonitrile 24 0.6
Dichloroacetonitrile 9.6 0.2
Trichloroacetonitrile 15 0.3
l
l
l
l
m
l
m
m
l
l
l
n
l
l
l
l
l
m
m
l
l
m
m
m
m
k
Percent Removal
PA
E
MCL
(µg/L)
>98 2.0
97 3.0
>
99 5.0
>99 40
98 5.0
99 100
99 NA
98 70
>99 0.2
99 600
98 75
n
95
5.0
99 7.0
>99 70
99 100
99 5.0
99 NA
99 7.0
99 2.0
99 700
>99 0.05
98 NA
98 NA
98 NA
98 NA
verage
p
k
Contaminant
A
Influent (µg/L)
Haloketones (HK):
1,1-Dichloro-2­propanone
1,1,1-Trichloro-2­propanone
Heptachlor 25 0.01
Heptachlor Epoxide 10.7
Hexachlorobutadiene 44 1.0
Hexachlorocyclopenta­diene
Lindane 55 0.01
Methoxychlor 50 0.1
Pentachlorophenol 96 1.0
Simazine 120 4.0
Styrene 150 0.5
1,1,2,2-Tetrachloroethane
Tetrachloroethylene 81 1.0
Toluene 78 1.0
2,4,5-TP (Silvex) 270 1.6
Tribromoacetic Acid 42 1.0
1,2,4-Trichlorobenzene 160 0.5
1,1,1-Trichloroethane 84 4.6
1,1,2-Trichloroethane 150 0.5
Trichloroethylene 180 1.0
Trihalomethanes (incl.):
Chloroform (surrogate chemical)
Bromoform
Bromodichloromethane
Chlorodibromomethane
Xylenes (total) 70 1.0
j
aximum
M
Effluent
k
(µg/L)
7.2 0.1
8.2
o
0.3
o
0.2
60 0.002
81 1.0
m
m
l
o
l
l
l
l
l
l
l
l
l
l
l
l
m
l
l
k
l
Percent Removal
99 NA
96 NA
>99 0.4
98 0.2
98 NA
>99 50
>99 0.2
>99 40
99 1.0
97 4.0
>99 100
99 NA
99 5.0
99 1,000
99 50
98 NA
>99 70
95 200
>99 5.0
>99 5.0
E
MCL
(µg/L)
300 15 95 80
l
99 10,000
PA
p
k
j
Influent challenge levels are average influent concentrations determined in surrogate qualification testing.
k
Micrograms per liter, which is equivalent to parts per billion (PPB).
l
Maximum product water level was not observed, but set at the detection limit of the analysis.
m
Maximum product water level set at a value determined in surrogate qualification testing.
n
Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point, as determined in surrogate qualification testing.
o
The surrogate test results for Heptachlor Epoxide demonstrated a 98% reduction. These data were used to cal­culate an upper occurrence concentration, which would produce a maximum product water level at the MCL.
p
Environmental Protection Agency maximum contaminant level as required under the Safe Drinking Water Act.