ONE YEAR LIMITED WARRANTY ON DUAL STAGE WATER FILTRATION SYSTEM
(except filter cartridges)
Warrantor: Ecodyne Water Systems, 1890 Woodlane Drive, Woodbury, MN 55125
Warrantor guarantees, to the original owner, that the Water Filtration System, when installed and maintained in accordance
with the instructions, will be free from defects in materials and workmanship for a period of one (1) year from the date of
purchase. If, within the first year, a part proves, after inspection, to be defective, Warrantor will, at its sole option, either
replace or repair the part without charge except normal shipping and installation charges. Labor to maintain the equipment
is not part of the warranty. Filters, which are expendable, are not covered by the warranty.
TO OBTAIN WARRANTY PARTS, SIMPLY CALL 1-866-986-3223, Monday - Friday, 7 am - 6 pm CST, for assistance. This
warranty applies only while this product is in use in the United States or Canada.
General Provisions
The above warranties are effective provided the Water Filtration System is operated at water pressures not exceeding 125
psi, and at water temperatures not exceeding 100°F; provided further that the Water Filtration System is not subject to
abuse, misuse, alteration, neglect, freezing, accident or negligence; and provided further that the Water Filtration System is
not damaged as the result of any unusual force of nature such as, but not limited to, flood, hurricane, tornado or earthquake.
Warrantor is excused if failure to perform its warranty obligations is the result of strikes, government regulation, materials
shortages, or other circumstances beyond its control.
*THERE ARE NO WARRANTIES ON THE WATER FILTRATION SYSTEM BEYOND THOSE SPECIFICALLY
DESCRIBED ABOVE. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED TO THE EXTENT THEY MIGHT EXTEND
BEYOND THE ABOVE PERIODS. THE SOLE OBLIGATION OF WARRANTOR UNDER THESE WARRANTIES IS TO
REPLACE OR REPAIR THE COMPONENT OR PART WHICH PROVES TO BE DEFECTIVE WITHIN THE SPECIFIED
TIME PERIOD, AND WARRANTOR IS NOT LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. NO WARRANTOR DEALER, AGENT, REPRESENTATIVE, OR OTHER PERSON IS AUTHORIZED TO EXTEND OR EXPAND
THE WARRANTIES EXPRESSLY DESCRIBED ABOVE.
Some states do not allow limitations on how long an implied warranty lasts or exclusions or limitations of incidental or consequential damage, so the limitations and exclusions in this warranty may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. This warranty applies to consumer-owned
installations only.
Manufactured under license by Ecodyne Water Systems, Woodbury, Minnesota.
Supply Water Temperature Min. - Max.40 - 100 °F (4 - 38 °C)
Rated Service Flow0.5 gallons per minute (1.89 liters per minute)
Filter Service Life270 gallons (1,022 liters)
Inlet - Outlet3/8" quick connect fittings
This system conforms to NSF/ANSI 42 and 53 for the specific performance claims as verified and substantiated by
test data.
This filter improves the taste and odor and reduces many chemical contaminants in drinking water. The faucet indicator monitors the length of time the filter has been installed and will flash amber continuously, indicating the filters
and battery need to be replaced.
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. The testing
was performed using spiked tap water at a flow rate of 0.5 GPM (1.89 L/min.), pH of 7.5 ±0.5, pressure of 60 PSIG,
and temperature of 68 ±5°F.
IMPORTANT NOTICE: Read this performance data and compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water supply
tested to determine your actual water treatment needs. This filter system is designed to be used for the reduction of
the performance claims listed below. Do not use where water is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. While testing was performed under standard laboratory conditions, actual
performance of the system may vary based on local water conditions. Some or all of the contaminants reduced by
this unit may not be in your water supply. See elsewhere in this manual for instructions on filter cartridge
replacement, system installation, operating procedures, and warranty. The maintenance instructions must
be followed for the product to perform as indicated below.
NOTE: See labels on the water treatment system for additional information.
0 - 100 psi (207 - 689 kPa)
3
PERFORMANCE CLAIMS
Required
Contaminant
Influent
Level (mg/L)
Cyst≥50,000 #/mL
Lead @ pH 6.50.15 ±10%0.0100.1520.001 / 0.00199.3 / 99.30.015
Lead @ pH 8.50.15 ±10%0.0100.1500.001 / 0.00199.3 / 99.30.015
Environmental Protection Agency maximum contaminant level as required under the Safe Drinking Water Act.
k
Milligrams per liter, which is equivalent to parts per million (PPM).
l
NSF minimum percent reduction requirement. Acceptance level for this substance is based on percent reduction,
rather than maximum effluent concentration.
m
Particles per milliliter.
n
Microspheres was used as a surrogate.
o
The EPA has not determined a maximum contaminant level for this chemical.
p
Chloroform was used as a surrogate for the reduction of chemicals specified in the Organic Chemicals Reduced
by Chloroform Surrogate Testing table (on the following page).
NSF Max. Per -
missible Effl.
k
Level (mg/L)
mn
99.95%
l
l
l
Average
k
Level (mg/L)
93,000 #/mL
Influent
Avg. / Max.
Effluent
k
Level (mg/L)
m
<1 /<4 #/mLm99.99 / 99.99None
Avg. / Min.
k
Removal
Percent
EPAjMax.
Contaminant
Level (mg/L)
2.00.05 / 0.0897.5 / 96.2None
0.3200.0005 / 0.000599.8 / 99.80.080
k
o
o
o
3
Performance Claims (continued)
ORGANIC CHEMICALS REDUCED BY CHLOROFORM SURROGATE TESTING
j
Contaminant
verage
A
Influent
(µg/L)
k
aximum
M
Effluent
(µg/L)
Alachlor501.0
trazine1003.0
A
Benzene811.0
Carbofuran1901.0
Carbon Tetrachloride781.8
Chlorobenzene771.0
Chloropicrin150.2
2,4-D1101.7
Dibromochloropropane
(DBCP)
520.02
o-Dichlorobenzene801.0
p-Dichlorobenzene401.0
1,2-Dichloroethane884.8
1,1-Dichloroethylene831.0
cis-1,2Dichloroethylene
trans-1,2Dichloroethylene
1700.5
861.0
1,2-Dichloropropane801.0
cis-1,3Dichloropropylene
791.0
Dinoseb1700.2
Endrin530.59
Ethylbenzene881.0
Ethylene Dibromide
(EDB)
440.02
Haloacetonitriles (HAN):
Bromochloroacteonitrile
220.5
Dibromoacetonitrile240.6
Dichloroacetonitrile9.60.2
Trichloroacetonitrile150.3
l
l
l
l
m
l
m
m
l
l
l
n
l
l
l
l
l
m
m
l
l
m
m
m
m
k
Percent
Removal
PA
E
MCL
(µg/L)
>982.0
973.0
>
995.0
>9940
985.0
99100
99NA
9870
>990.2
99600
9875
n
95
5.0
997.0
>9970
99100
995.0
99NA
997.0
992.0
99700
>990.05
98NA
98NA
98NA
98NA
verage
p
k
Contaminant
A
Influent
(µg/L)
Haloketones (HK):
1,1-Dichloro-2propanone
1,1,1-Trichloro-2propanone
Heptachlor250.01
Heptachlor Epoxide10.7
Hexachlorobutadiene441.0
Hexachlorocyclopentadiene
Lindane550.01
Methoxychlor500.1
Pentachlorophenol961.0
Simazine1204.0
Styrene1500.5
1,1,2,2-Tetrachloroethane
Tetrachloroethylene811.0
Toluene781.0
2,4,5-TP (Silvex)2701.6
Tribromoacetic Acid421.0
1,2,4-Trichlorobenzene1600.5
1,1,1-Trichloroethane844.6
1,1,2-Trichloroethane1500.5
Trichloroethylene1801.0
Trihalomethanes (incl.):
Chloroform
(surrogate chemical)
Bromoform
Bromodichloromethane
Chlorodibromomethane
Xylenes (total)701.0
j
aximum
M
Effluent
k
(µg/L)
7.20.1
8.2
o
0.3
o
0.2
600.002
811.0
m
m
l
o
l
l
l
l
l
l
l
l
l
l
l
l
m
l
l
k
l
Percent
Removal
99NA
96NA
>990.4
980.2
98NA
>9950
>990.2
>9940
991.0
974.0
>99100
99NA
995.0
991,000
9950
98NA
>9970
95200
>995.0
>995.0
E
MCL
(µg/L)
300159580
l
9910,000
PA
p
k
j
Influent challenge levels are average influent concentrations determined in surrogate qualification testing.
k
Micrograms per liter, which is equivalent to parts per billion (PPB).
l
Maximum product water level was not observed, but set at the detection limit of the analysis.
m
Maximum product water level set at a value determined in surrogate qualification testing.
n
Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point,
as determined in surrogate qualification testing.
o
The surrogate test results for Heptachlor Epoxide demonstrated a 98% reduction. These data were used to calculate an upper occurrence concentration, which would produce a maximum product water level at the MCL.
p
Environmental Protection Agency maximum contaminant level as required under the Safe Drinking Water Act.
4
Loading...
+ 8 hidden pages