Whirlpool WHAB-6013, WHAF-0435AC, WHAB-6014, WHAB-6012, WHAB-6015 User Manual

...
UNDER SINK
MODULAR
FILTRATION SYSTEM
Installation Instructions and
Use and Care Guide
For questions about features, operation/performance,
parts, accessories or service, call: 1-866-363-9472.
Or visit our website at www.whirlpool.com
PURIFICACIÓN
MODULAR
PARA INSTALAR
BAJO FREGADEROS
Instrucciones de instalación
y guía de usos y cuidados
Para mayor información sobre características, operación
y funcionamiento, repuestos, accesorios o servicio
técnico, comuníquese al 1-866-363-9472.
O visite nuestra página en Internet... www.whirlpool.com
Table of Contents/Índice......................................... 2
model / modelo model / modelo WHAB-6014 WHAB-6012 WHAB-6015 WHAB-6013
8563999 / OEM030099-284
model / modelo model / modelo WHAF-0335AB WHAF-0435AC
System tested and certified by NSF International against ANSI/NSF Standard 53 for Lead, Cyst and VOC Reduction (see the claims specified on the Performance Data Sheet) and Standard 42 for Chlorine, Taste and Odor Reduction.
Sistema verificado y certificado por el instituto NSF International según lo dispuesto por la norma ANSI/NSF 53 en lo que se refiere a la disminución de plomo, esporas y COV (ver lo dispuesto en la ficha técnica de rendimiento) y la norma 42 en lo que se refiere a la disminución de cloro, sabor y olor.
The WHAB faucet unit is tested and certified by NSF International against ANSI/NSF Standard 42 for material and structural integrity requirements only.
El grifo WHAB ha sido verificado y certificado por el instituto NSF International según lo establecido por la norma 42 NSI/NSF 42en lo que se refiere a la integridad estructural y de los materiales únicamente.
2
PRESENTACIÓN DEL SISTEMA DE PURIFICACIÓN MODULAR ULTRAEASE™ PARA INSTALAR
BAJO FREGADEROS.............................................................. 18
ASISTENCIA O SERVICIO TÉCNICO.................................... 18
REQUISITOS PARA LA INSTALACIÓN.................................. 19
Requisitos para la ubicación.................................................19
Requisitos del suministro de agua..................................... 22
INSTRUCCIONES PARA LA INSTALACIÓN.......................... 22
Herramientas y piezas............................................................ 22
Instalación de la válvula de la cabeza del filtro y el
cartucho que contiene el filtro............................................ 24
Instalación del grifo................................................................ 26
Conexión del grifo a los filtros............................................ 27
ACCESORIOS PARA EL SISTEMA DE PURIFICACIÓN..... 28
LIMPIEZA DEL SISTEMA DE PURIFICACIÓN................... 28
MONITOR DE CIRCULACIÓN DE AGUA............................ 28
CARACTERÍSTICAS DEL GRIFO
(WHAB-6014, WHAB-6015)................................................ 28
Rociador de legumbres.......................................................... 28
CUIDADOS DEL GRIFO (WHAB-6014, WHAB-6015)..... 28
Limpieza...................................................................................... 28
ANTES DE LLAMAR AL SERVICIO TÉCNICO.................... 29
GUÍA DE PROBLEMAS Y SOLUCIONES............................ 29
GARANTÍA DE LA UNIDAD DE PURIFICACIÓN
ULTRAEASE™.......................................................................... 30
FICHAS TÉCNICAS DE RENDIMIENTO.............................. 31
TABLE OF CONTENTS
ÍNDICE
INTRODUCTION TO ULTRAEASE™ UNDER SINK
MODULAR FILTRATION SYSTEM.......................................... 3
ASSISTANCE OR SERVICE.......................................................3
INSTALLATION REQUIREMENTS.............................................. 3
Location Requirements.............................................................4
Water Supply Requirements....................................................6
INSTALLATION INSTRUCTIONS................................................ 7
Tools and Parts............................................................................ 7
Install the Filterhead Valve and Filter Cartridge................8
Install the faucet........................................................................10
Connect faucet to filters..........................................................11
FILTRATION SYSTEM ACCESSORIES.................................. 12
FLUSHING THE FILTRATION SYSTEM................................ 12
FLOW MONITOR.................................................................... 12
FAUCET FEATURES (WHAB-6014, WHAB-6015)............. 12
Vegetable sprayer......................................................................12
FAUCET CARE (WHAB-6014, WHAB-6015)......................12
Cleaning.......................................................................................12
BEFORE CALLING FOR SERVICE........................................ 12
TROUBLESHOOTING.............................................................13
ULTRAEASE™ FILTRATION UNIT WARRANTY...................13
PERFORMANCE DATA SHEETS............................................14
33
Welcome to a New Era in Home Water Filtration Systems. Thank you for purchasing the UltraEase™ Modular filtration system, Whirlpool Brand's latest innovative under sink water filtration
system. This system will provide you with many years of great-tasting water. Whether from your town’s water treatment plant or decaying pipes in your home, sediment rust, sand, silt and iron can be present in
your water. What’s more, chlorine, lead and cyst levels may further affect the quality of your water. Your new UltraEase™ easy to con­nect filters, effectively reduce these unwanted particles from your water supply more simply than ever.
The unit’s NSF-certified filter cartridges have been tested to process up to 1,200 gallons of water before any replacement is needed (approximately 6 to 12 months* depending on your water consumption and flow rate). See the last page for more details. Replacing a filter is an easy “lift ‘n’ snap” operation, complete with an automatic shut-off water valve. And should you decide to upgrade to a more comprehensive water filtration system, your UltraEase™ easy to connect Filter Unit’s modular design allows you to add on other components that filter chemicals for even better-tasting water. As an option, you can also add to your system the DirectChill™ and/or the DirectHot™ units.
* The contaminants or other substances removed or reduced by this water filter are not necessarily in all users' water. Filter life varies depending on local water conditions and the volume of water used. We recommend you change your filter every 12 months. However, it can be replaced earlier if there is a drop in pressure at the faucet or when the monitor indicates.
INTRODUCTION ULTRAEASE™ UNDER SINK
MODULAR FILTRATION SYSTEM
Dealer name _______________________________________________________________________________________________________
Address ___________________________________________________________________________________________________________
Phone number_________________________________ Model number_____________________________________________________
Purchase date______________________________________________________________________________________________________
ASSISTANCE OR SERVICE
If you need assistance or service, first see “Troubleshooting” section. Additional help is available by calling 1-866-363-9472. Monday to Friday 8:00 a.m. - 6:00 p.m. (EST) or write:
Whirlpool Water Products P.O. Box 13150 Columbus, OH 43213-0150
Please include a daytime phone number in your correspondence.
For installation and service, call: 1-866-363-9472 or visit our website at www.whirlpool.com.
Keep this book and your sales slip together for future reference. You must provide proof of purchase or installation date for in-warranty service.
Write down the following information about your appliance to help you obtain assistance or service if you need it. You will need to know your complete model number. You can find this information on the packaging.
INSTALLATION REQUIREMENTS
IMPORTANT:
Observe all governing codes and ordinances. Check location where the faucet will be installed. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with installation specifications and with state and local plumbing codes.
The faucet requires a 1-3\8’’ (3.5cm) diameter opening in the sink or countertop. The faucet can be installed in place of the sink spray hose. If faucet is not to be installed in sink spray hose opening, it is recommended that a qualified installer be contacted to drill a hole through your sink or countertop. Thickness of countertop at the hole must not exceed 1-3/4’’ (4.4cm).
Cold water supply connection must be available. See ‘’Water supply requirements’’, section. Water connections use easy to connect fittings which do not require sealing compounds to keep them from leaking.
4
Filtration unit layouts
Layout 1
Installing UltraEase™ Dual stage water filtration Unit A+B (WHAF-0335AB), requires the Whirlpool™ UltraEase™ faucet (WHAB-6012 or 6013 or 6014 or 6015) sold separately.
Layout 2
Installing UltraEase™ Specialty water filtration Unit C (WHAF-0435AC sold separately), requires the UltraEase™ Dual stage water filtration Unit A+B (WHAF-0335AB) and Whirlpool™ UltraEase™ faucet (WHAB-6012 or 6013 or 6014 or 6015) sold separately.
If faucet is not to be installed in sink spray hose opening, cut 1-3/8” (3.5 cm) dia. sink or countertop cutout.
1-3/4” (4.4 cm) max. countertop or sink thickness.
1. Faucet installed in spray hose opening in sink (styles vary by model)
2. Cold water supply line
3. White tube included with faucet
4. “T” water line connector included
with faucet
5. Flow monitor included with faucet
6. Wall mounting clips for tubing
7. White “water in” collet
8. Blue “water out” collet
Note:
On the easy to connect fittings the white collet represents “water in”. The blue collet represents “water out”.
1
2
3
3
3
4
5
1. Faucet installed in spray hose opening in sink (styles vary by model)
2. Cold water supply line
3. White tube included with faucet
4. “T” water line connector included
with faucet
5. Specialty filtration sold separately
6. Flow monitor included with faucet
7. Wall mounting clips for tubing
8. White “water in” collet
9. Blue “water out” collet
1
2
3
3
3
4
5
6
6
7
7
8
8
9
Location Requirements
5
Layout 4
Adding the UltraEase™ DirectHot™ unit (WHAF-0115AF), requires the UltraEase™ Dual water filtration Unit A+B (WHAF-0335AB).
IMPORTANT:
A Dual temperature faucet is included with the DirectHot™ unit. It does not require the faucet model WHAB-6012 or 6013 or 6014 or 6015.
UltraEase™ Specialty water filtration Unit C (WHAF-0435AC) is optional in this layout (sold separately).
7. 37 5"
(18.8 cm)
8.50"
(21.6 cm)
1. Dual temperature faucet included with the DirectHot™ unit
2. Cold water supply line
3. White tube included with DirectHot™ unit
4. Specialty filtration sold separately
5. Flow monitor included
DirectHot™ unit
6. “T” water line connector included
with faucet
7. DirectHot™ unit
8. Yellow tubing
9. Red tubing
10. Wall mounting clips for tubing
11. White “water in” collet
12. Blue “water out” collet
12"
(30.5 cm)
1
2
3
9
3
4
5
6
7
8
10
Layout 3
Adding the UltraEase™ DirectChill™ unit (WHAF-0115AG), requires the UltraEase™ Dual water filtration Unit A+B (WHAF-0335AB) and Whirlpool™ UltraEase™ faucet (WHAB-6012 or 6013 or 6014 or 6015) sold separately.
UltraEase™ Specialty water filtration Unit C (WHAF-0435AC) is optional in this layout (sold separately).
1. Faucet installed in spray hose opening in sink (styles vary by model)
2. Cold water supply line
3. White tube included with faucet
4. Specialty filtration sold separately
5. Flow monitor included with faucet
6. “T” water line connector included
with faucet
7. DirectChill™ unit
8. Blue tube included with chiller
9. Wall mounting clips for tubing
10. White “water in” collet
11. Blue “water out” collet
14.75"
(37.46 cm)
10.30"
(26.16 cm)
8.72"
(22.14 cm)
1
2
3
3
4
5
6
7
8
9
10
11
11
12
6
If local codes permit, connect the UltraEase™ modular filtration system feed line to the cold water supply line with the ‘’T’’ connector (supplied with UltraEase™ faucets product number WHAB-6012, WHAB-6013, WHAB-6014, WHAB- 6015 and DirectHot™ unit WHAF-0115AF).
If you are using the UltraEase™ filtration unit, the Directchill™ unit and/or the DirectHot™* unit should be connected after the filtration unit.
IMPORTANT: If local codes do not permit the use of the ‘’T’’ connector, special feed valves can be obtained from your local plumbing supply distributor. Do not connect the filters to the hot water line. This will ruin the filters. The water pressure to the DirectChill™ unit or DirectHot™* unit should not drop below 30 psi (min.) nor rise above 100 psi (max.).
Layout 5
If you wish to add the UltraEase™ DirectHot™ unit (WHAF-0115AF) and the UltraEase™ DirectChill™ unit (WHAF-0115AG), it will require the UltraEase™ Dual water filtration Unit A+B (WHAF-0335AB).
IMPORTANT:
A Dual temperature faucet included with the Direct Hot unit. It does not require the faucet model WHAB-6012 or 6013 or 6014 or 6015. UltraEase™ Specialty water Filtration Unit C (WHAF-0435AC) is optional in this layout (sold separately).
1. Dual temperature faucet included with the DirectHot™ unit
2. Cold water supply line
3. White tubing with included DirectHot™ unit
4. Specialty filtration sold separately
5. Flow monitor included with
DirectHot™ unit
6. “T” water line connector included
with faucet
7. DirectChill™ unit
8. DirectHot™ unit
9. Yellow tubing
10. Red tubing
11. Blue tubing included with chiller
12. Wall mounting clips for tubing
13. White “water in” collet
14. Blue “water out” collet
1
2
3
4
5
6
7
8
11
9
10
12
*Delineated that the DirectHot™ unit is not tested or certified by NSF International.
13
14
Water Supply Requirements
IMPORTANT:
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems that are certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
Tools and Parts
8
5
7
INSTALLATION INSTRUCTIONS
Dual stage water filtration system
(model WHAF-0335AB)
Parts Supplied
1. Filter cartridge Unit A
2. Filter cartridge unit B
3. Easy-mount template
4. 2 Filterhead valves
5. 2 Mounting brackets
6. 4 Phillips head screws
7. 1 connector tube
8. 2 elbow fittings (one with blue collet and one with white collet)
Additional filtration available
Specialty water filtration system
(model WHAF-0435AC)
Parts Supplied
1. Filter cartridge Unit C
2. 1 Filterhead valve
3. 1 Mounting bracket
4. 2 Phillips head screws
5. 1 connector tube
Pencil
Measuring tape
Phillips screwdriver
Small level
Drill with 1/16’’ drill bit
1-3/8’’ hole saw
Adjustable wrench
Utility knife
1
3
4
5
6
7
1
2
4
3
2
Assemble the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools Needed
13
1. Determine the cartridge installation location on the wall under the sink. The mounting template is to help you to locate the mounting bracket. Keep in mind that the center of the top holes on the mounting template must be at least 14’’ (35.6 cm) from the bottom of the under sink cabinet. Position the mounting template securely with tape. Once template is level, drill the guide holes.
NOTE: Be careful not to drill into plumbing or wiring inside the wall.
A
unitBunitCunit
14
2. Using 2 Phillips head screws provided, mount 1 bracket to wall (position on left for Unit A).
3. Mount Unit B mounting bracket to wall, to the immediate right of Unit A bracket. The brackets should interlock with each other.
Tabs must be located at the bottom.
8
Standard or tall neck faucet
Parts Supplied
1. Faucet
2. 8 feet of white tubing
3. 1 rubber washer
4. 1 metal retaining bracket
5. 1 retaining nut
6. 1 threaded rod
7. 4 Phillips screw
8. ‘’T’’ water line connector
9. Flow monitor indicator ring and switch
10. Flow monitor
11. 2 AA batteries
12. Cap
13. 2 wall mounting clips
1or
2
8
9
10
11
12
3
4
5
6
7
Install the Filterhead Valve
and Filter Cartridge
4. Press filterhead valve firmly against the top of the mounting bracket.
Pressing firmly, slowly slide the filterhead valve downwards until both the top and bottom tabs are secure.
Slide the filterhead valve to the center of the mounting bracket. (You should hear a slight click when filterhead valve is secure).
Click
1
2
3
5. Make sure filterhead valve is open by pulling up on the center front.
model WHAB-6014 model WHAB-6012 model WHAB-6015 model WHAB-6013
6. Grasp the base of the filter cartridge with the word “Front” facing you.
FRONT
FRONT
7. Lay the filter cartridge into the filterhead valve cradle.
FRO
N
T
FRONT
9
8. Push filter catridge up into the filterhead valve until it stops. The 2 colorstrips should be aligned (one in the filterhead valve cradle and one in the filter cartridge).
FRONT
FRONT
FRONT
FRONT
FRONT
FRONT
IMPORTANT:
Do not install the filter cartridge as shown below.
11. Take the “B” filterhead valve and place it at the top right of the mounting bracket. Pressing the filterhead valve firmly against the mounting bracket, slide the unit downwards securing both the top and bottom tabs.
12. Slide the “B” filterhead valve to the left, making sure the connector tube goes into the “B” filterhead valve white collet “water in”. Slide to the left until it is centered on the second mounting bracket. (You should hear a slight click, when “B” filterhead valve is secure). If you do not install the filter C, put the elbow fitting with the blue collet into “B” filterhead valve blue collet “water out”.
13. Repeat step 5 to install filter B.
1
2
10. Place the connector tube into
the blue collet “water out” on the right side of the first assembled filterhead valve.
9. Push back on a downward arc
until the filter cartridge stops.
FRONT
FRONT
How to insert tubing
in easy to connect fitting
Collet Body
Tube
Figure A Figure B Figure C
Insert the tubing squarely. See figure A. Make sure to insert tube completely. See figure B. Push in collet while removing tube. See figure C.
8. Slide the flow monitor indicator
ring up to the base of the faucet over the 48” tubing and the threaded rod.
Make sure the key is inserted into the key slot on the faucet bottom.
9. Place the rubber washer on the
sink surface over the hole. Drop the 48” tubing and faucet assembly down into the hole in the sink. Make sure the flow monitor wire goes in that hole.
Key
10
14. If you install filterhead valve C, repeat steps 2 to 7. If you do not install filterhead valve C (WHAF-0435AC), go to “Install the faucet” section.
Click
1
2
NOTE: At this point, you could install the DirectChill unit
(WHAF-0115AG) and/or the DirectHot unit with dual faucet (WHAF-0155AF) sold separately. Please refer to the Use and Care Guides for those specific products.
If you do not install these options, please follow the next steps.
4. Remove hose guide and gasket from sink hole.
10. From below, install the C
shape metal retaining plate over the threaded valve.
5. With a utility knife, cut the white tubing at 4 feet. Make sure to make a clean cut at a 90° angle.
IMPORTANT: After cutting the tube, squeeze the tubing back to a round shape.
6. Insert the white tubing into the collet at the bottom of the faucet. Make sure if tubing is fully inserted in the collet.
7. Screw the threaded rod into the faucet base with Phillips screwdriver until tight.
IMPORTANT: Cap the sprayer hose outlet with the included cap. Use seal compound or Teflon®tape to make a water tight seal.
2. Remove sprayer.
See the Location requirements and the Water supply requirements section prior to starting the faucet installation.
NOTE: If your existing faucet has a removable sprayer and you would like to install your new UltraEase faucet in the sprayer hole, start the installation at step 9. If not, start at step 14.
1. Turn off both hot and cold water supply to your faucet. Disconnect sprayer hose from faucet fitting.
Install the faucet
flow monitor indicator ring
3. From under sink, remove locknut of hose guide.
11
11. Screw on the retaining nut to secure the faucet.
Connect faucet to filters
3. Insert the 12” long white tubing
into the white collet of the flow monitor inlet.
1
1. Insert elbow fitting with blue
collet into the blue collet flow monitor outlet.
2. Insert the white tubing into
the blue collet of the elbow of the flow monitor outlet.
NOTE: If you choose to install the DirectChill™ unit, connect this tubing to the DirectChill™ unit (for more details please refer to the DirectChill™ Use and Care Guide).
2
4. Connect the other tubing end
to the blue collet elbow of the filterhead valve B (or C if installed).
5. With the 2 Phillips head screws,
install the flow monitor to the cabinet wall.
6. Connect the flow monitor wire to the faucet flow monitor by inserting the connection plug into the flow monitor inlet.
9. Install T-fitting included. Use seal compound or Teflon®tape.
8. Disconnect the cold water line to your sink faucet.
7. Remove screw from cover and install 2 AA batteries in the flow monitor. Replace cover and screw.
10. Cut the white tubing to fit the required installation location. Push white tubing into easy to connect port of T-fitting. Connect the other end to the filterhead valve elbow fitting of filterhead valve A (white collet).
11. Double check all connections by pulling gently on each portion of tubing.