Display Description Explanation/Recommended Procedure
F
:
29
Moisture
Sensor
Shorted
F:29 flashesifthe moisture sensor striphas
shorted. Thisfault codeappears ONLYwhen
in the DiagnosticTest Mode.
■
See TEST #5, page 11.
F
:
30
Restricted
Air Flow
Condition
F:30 flashesifarestricted air flow condition
exists. Thisfault codeappears ONLYwhen in
the DiagnosticTest Mode.
■
Checktomake sure the lint screenisclean,
the door seal is in place and the ventisnot
obstructed.
■
SeeDIAGNOSTIC: Displaying InletAirFlow,
page3.
F
:
31
L2
Line
Voltage Error
F:31 flashesifalow voltage condition (less than
30V) has been detected. This fault code appears
ONLY wheninthe DiagnosticTest Mode.
■
Checktoseeifahousehold fuse has blown
or a circuit breaker has tripped.
■
Confirm the power cordisproperly installed
and plugged into the power outlet.
■
Check the relay connectionsonthe
electronic control.
F
:
70
or
F
:
71
No
Communication
Between
Electronic
Assemblies
F:70 / F:71 flashes when thereisno
communication betweenthe machine control
and theconsole electronics.
■
Check console electronics harness
connectionstothe machine control.
■
Replace the machine control electronics.
See Accessing&Removing the Electronic
Assemblies, page 13.
F
:
72
through
F
:
78
Console
Electronics
Failure
F:72 through F:78 flasheswhen thereisa
console electronicsfailure.
■
Replace the console electronics. See
Accessing&Removing the Electronic
Assemblies, page 13.
Affichage Description Explicationsetopérations recommandées
Capteur
d’humidité–
court-circuit
F:29 clignote pour signaleruncourt-circuit affectantlecapteur
d’humidité.Cecode d’anomalie apparaît SEULEMENT lorsque
le modedetestdediagnostic est actif.
■
Voir TESTno5, page11.
Restriction
du débit d’air
F:30 clignoteencasderestrictiondudébit d’air.Cecode
d’anomalie apparaîtSEULEMENTaumodedetestdediagnostic.
■
Vérifier queletamisàcharpie est propre, quelejointdeporte
est en placeetquelabouchededécharge n’est pasobstruée.
■
Voir DIAGNOSTIC:Affichagedudébit d’airàl’entrée, page 3.
L2
Tension
d’alimentation –
erreur
F:31 clignotesiune tensiond’alimentation insuffisante(moins de
30 V)a étédétectée.Cecode d’anomalie apparaît SEULEMENT au
mode “Testdediagnostic”.
■
Déterminer siun fusiblede larésidence estgrillé ousi un
disjoncteur s’estouvert.
■
Vérifier quelecordon d’alimentation est bien installéetbranché
sur uneprisedecourant alimentée.
■
Contrôler lesconnexionsdurelais surlacarte des circuits de
commande électronique.
ou
Absence
de
communication
entre les
modules
électroniques
F:70 ou F:71 clignote s’il n’yapasdecommunication entre les
modules électroniques(commandes dela machineetconsole).
■
Contrôler lesconnexionsducâblagederaccordement entre le
module électroniquede laconsole etle moduledecommande
de la machine.
■
Remplacerlemoduledecommande électronique de la machine.
Voir Modulesélectroniques–Accèsetdépose, page 13.
à
Défaillance
du module
électronique
de la console
F:72 à F:78 clignoteenprésence d’unedéfaillancedumodule
électronique dela console.
■
Remplacer l’ensemblecircuits électroniques/carterdela
console. VoirModules électroniques–Accèsetdépose, page 13.
TROUBLESHOOTING GUIDE Some tests will require accessing
components. See figure 2, page 6, for component locations.
Problem
Possible Cause/Test
NOTE: Possible Cause/Tests MUST
be performed in the sequence
shown for each problem.
Won’t power up. (No response
when buttons are pressed.)
1. Supply connections. See
TEST #1, page 6.
2. Check harness connections.
3. Console electronics and
housing assembly. See
TEST #6, page 12.
Won’t start cycle when Start
button is pressed.
1. If number display flashes, check
to be sure the dooriscompletely
shut, and press and hold down
Start for about1second.
2. See TEST #3, page 7.
3. See TEST #7, page 13.
Won’t shut off when expected.
1. Check Pause/Cancel button.
2. Console electronics and housing
assembly.SeeTEST#6,page 12.
3. Moisture sensor. See TEST #5,
page 11.
Control won’t accept selections.
Console electronics and housing
assembly. See TEST #6, page 12.
Problem
Possible Cause/Test
Won’t heat.
1. Heater. See TEST #4, page 8.
2. Check harness connections.
3. See DIAGNOSTIC: Displaying
Line Voltage, page 3.
4. Check installation.
Heats in air cycle.
Heater. See TEST #4, page 8.
Shuts off before clothes are dry.
1. Check the dryness setting for
auto cycles.
2. Check for full lint screen.
3. See DIAGNOSTIC: Displaying
Inlet Air Flow, page 3.
4. Check for clogged vent.
5. Moisture sensor. See TEST #5,
page 11.
6. Dryness level adjust. See
TEST #5a, page 12.
PushingPower button causes dryer to beep, butnoindicators light.
1. Check console electronics
harness connectionstothe
machine control.
2. Replace machine control
electronics. See Accessing&
Removing the Electronic
Assemblies, page 13.
GUIDE DE DÉPANNAGE Certains tests nécessitent l’accès aux composants. Pour la
position de chaque composant, voir la figure 2, page 6.
Problème
Cause possible/test
NOTE : Les étapes des tests DOIVENT être
exécutées dans l’ordre présenté ci-dessous
pour chaque problème.
Pas de mise en marche. (pas de réaction lors
des pressions sur les touches.)
1. Connexions d’alimentation. Voir TESTno1,
page 6.
2. Contrôler les connexionsducâblage.
3. Ensemble circuits électroniques/carter de
la console. Voir TESTn
o
6, page 12.
Pas de mise en marche du programme
lors de la pression sur la touche Start.
1. Si clignotement des chiffres sur l’afficheur,
vérifier quelaporte est parfaitement
fermée, appuyeretmaintenirlapression
sur Start (miseenmarche) pendant
environ1seconde.
2. Voir TESTn
o
3, page 7.
3. Voir TESTn
o
7, page 13.
Pas d’arrêt au moment prévu.
1. Contrôlerlebouton Pause/Cancel
(pause/annulation).
2. Ensemble circuit électronique/carterdela
console. Voir TESTn
o
6, page 12.
3. Capteur d’humidité. Voir TESTn
o
5,
page 11.
Le système de commande n’accepte pas
les sélections.
Ensemble circuit électronique/carterdela
console. Voir TESTn
o
6, page 12.
Problème
Cause possible/test
Aucun chauffage.
1. Systèmedechauffage. Voir TESTno4,
page 8.
2. Contrôler les connexionsducâblage.
3. Voir DIAGNOSTIC:Affichage de la tension
d’alimentation page 3.
4. Contrôler l’installation.
Chauffage pour le programme du séchage
à l’air.
Systèmedechauffage. Voir TESTno4, page 8.
Linge humide lorsdel’arrêtdelasécheuse.
1. Contrôlerleréglageducapteur d’humidité
pour les programmes automatiques.
2. Déterminer si le tamisàcharpie est rempli.
3. Voir DIAGNOSTIC:Affichagedudébit d’air,
page 3.
4. Déterminersil’évent est obstrué.
5. Capteur d’humidité. Voir TESTn
o
5, page 11.
6. Réglagedudegrédeséchage. Voir
TESTn
o
5a, page 12.
Une pression sur le bouton Power
provoque l’émission d’un signal sonore
mais aucun témoin ne s’illumine.
1. Contrôler les connexionsducâblage de
raccordement entrelemodule électronique
de la console et le moduledecommande
de la machine.
2. Remplacerlemoduledecommande
électronique de la machine. Voir aussi
Modules électroniques–Accès et
dépose, page 13.
F
:
2
9
F
:
30
F
:
31
F
:
70
F
:
71
F
:
72
F
:
78