Whirlpool WGD9300V, WGD9400V, wgd9200s, WGD9400S User Manual

An individual manual shutoff valve must be installed within six (6) feet (1.8m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.
*®TEFLON is a registered trademark of E.I. Dupont De
Nemours and Company
Dryer gas pipe: The gas pipe that comes out through the rear of your dryer has a 3/8" male thread.
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
WGD9200S WGD9300V
WGD9400S WGD9400V
WGD9500T WGD9600T
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10224610
11-09-08
Electrical: A 4-wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply on a separate 30-amp circuit, fused on both sides of the line is required. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
Exhaust venting: Exhaust your dryer to the outside. 4" (10.16 cm) diameter vent is required. Rigid or flexible heavy metal exhaust vent must be used. The total length of flexible metal vent should not exceed 7-3/4 ft. (2.4 m). Do not use plastic or metal foil vent. Exhaust outlet hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust.
Gas supply: This dryer is equipped for use with Natural gas. It is design-certified by CSA International for LP (propane or butane) gases with appropriate conversion.
No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.
Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer.
Gas Dryer
Page 1 of 3
A. ½" NPT gas supply line
B.
3
/8 NPT dryer pipe
A
B
*6¼" (15.9 cm)
1½" (3.8 cm)
®
REQUIREMENTS
1/2" IPS pipe is recommended. 3/8" approved aluminum or copper tubing is acceptable
for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.
If you are using Natural gas, do not use copper tubing. Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting. If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe joint compounds that resist the action of LP gas must be used. Do not use TEFLON®tape.*
Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.
This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
A
B
C
D
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A
38" (9652 mm) 38" (9652 mm)
B 32
9
/16" (686 mm) 31 1/2" (800 mm)
C 27" (686 mm) 27" (686 mm)
D 52
9
/16" (1335 mm) 51 1/2" (1308 mm)
* Most installations require a minimum 5" (127 mm) clearance behind the dryer for
the exhaust vent with elbow.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10224610
11-09-08
Gas Dryer
Page 2 of 3
Side view
Closet door with vents
Closet installation - Dryer only
A*
B C**
(460 mm)
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A*
1" (25 mm) 1" (25 mm)
B 32
9
/16" (686 mm) 31 1/2" (800 mm)
C** 5" (127 mm) 5" (127 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed.
Recessed or closet installation - Dryer on pedesta
A
B C D* E
F**
(460 mm)
l
Steam
(El
ectric or Gas)
Non-Steam
(Electric or Gas)
A
1" (25 mm) 1" (25 mm)
B 27" (686 mm) 27" (686 mm)
C 1" (25 mm) 1" (25 mm)
D* 1" (25 mm) 1" (25 mm)
E 32
9
/16" (686 mm) 31 1/2" (800 mm)
F** 5" (127 mm) 5" (127 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed
NOTE: Some models ar
e not recommended for recessed or closet
installation.
®
RECESSED AREA AND CLOSET INSTALLATION
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
RECOMMENDED INSTALLATION SPACING FOR CABINET INSTALLATION
NOTE: Some models are not recommended for cabinet installation.
For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.
A*
B*
C*
D**
E
F*
H
I
G
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A* 7" (178 mm) 7" (178 mm)
B* 7" (178 mm) 7" (178 mm)
C* 9" (229 mm) 9" (229 mm)
D** 5" (127 mm) 5" (127 mm)
E 32
9
/16" (686 mm) 31 1/2" (800 mm)
F* 1" (25 mm) 1" (25 mm)
G 1" (25 mm) 1" (25 mm)
H 27" (686 mm) 27" (686 mm)
I 1" (25 mm) 1" (25 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed.
PRODUCT MODEL NUMBERS
WGD9200S WGD9300V
WGD9400S WGD9400V
WGD9500T WGD9600T
Loading...
+ 1 hidden pages