Whirlpool WGD9200SQ, WGD9400ST, WGD9400SB, WGD9200WW, WGD9400SW Dimension Guide

...
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
EXHAUST VENTING
WGD9200S WGD9400S
WGD9300V WGD9400V
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10151593B
07-14-08
RECESSED AREA AND CLOSET INSTALLATION
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
A. Side view - closet or confined area B. Closet door with vents
A
B
14" max.* (35.6 cm)
18" min.* (45.72 cm)
1"*
5"**
(12.7 cm)
31½"
(80 cm)
48 in.
2*
(310 cm2)
24 in.
2*
(155 cm2)
3"*
(7.6 cm)
3"*
(7.6 cm)
(2.5 cm)
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
A. Recessed area B. Side view - closet or confined area
BA
1"
(2.5 cm)
1"
(2.5 cm)
1"*
(2.5 cm)
5"**
(12.7 cm)
27"
(68.6 cm)
31½"
(80 cm)
18" min.* (45.72 cm)
14" max.* (35.6 cm)
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
7"* (17.8 cm)
9"* (22.9 cm
)
7"* (17.8 cm)
5"**
(12.7 cm)
31
"
(80.0 cm)
27"
(68.6 cm)
1"* (2.5 cm)
1" 1"
(2.5 cm)
(2.5 cm)
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
A . Louvered hood style
B . Box hood style
4" (10.2 cm)
4" (10.2 cm)
A
B
Recommended hood styles
Dryer only
Dryer on pedestal
Angled hood style is
acceptable.
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need.
Recommended installation spacing for cabinet installation
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
Duet Electronic Gas Dryer
* Most installations require a minimum 5”
(12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See Installations Instructions, “Venting Requirements.”
®
Gas supply: Dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2 inch IPS. When acceptable to the gas supplier and local codes, 3/8 inch approved tubing may be used for lengths under 20 feet. For lengths over 20 feet, larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. If local codes permit, it is recommended that new flexible metal tubing, design-certified by CSA, be used for connecting the appliance to the rigid gas supply line. (The gas pipe which extends through the lower rear of the appliance has 3/8 inch male pipe thread.) An individual manual shutoff valve must be installed within 6 feet of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
Electrical: A four-wire or three-wire, single phase, 120-volt, 60 Hz, AC-only, electrical supply is required on a separate 15 or 20 amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the outside. Four inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
4"
(10.2 cm)
2.
½"
(6.4 cm)
0"
(0 cm)
1"* (2.5 cm)
1"* (2.5 cm)
38" min. (96.52 cm)
27" (68.6 cm)
*Required spacing
Undercounter installation
51½"
38"
(96.52 cm
)
*31½" (80 cm)
27"
(68.6 cm)
Number of 90° turns or elbows
NOTE:
inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Type of vent
0Rigid metal
Flexible metal
1Rigid metal
2Rigid metal
3Rigid metal
4Rigid metal
Side and bottom exhaust installations have a 90° turn
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Box or Louvered hoods
64 ft (20 m) 36 ft (11 m)
54 ft (16.5 m) 31 ft (9.4 m)
44 ft (13.4 m) 27 ft (8.2 m)
35 ft (10.7 m) 25 ft (7.6 m)
27 ft (8.2 m) 23 ft (7 m)
Angled hoods
58 ft (17.7 m) 28 ft (8.5 m)
48 ft (14.6 m) 23 ft (7 m)
38 ft (11.6 m) 19 ft (5.8 m)
29 ft (8.8 m) 17 ft (5.2 m)
21 ft (6.4 m) 15 ft (4.6 m)