29" and 27" Dryers
Gas (U.S.A. and Canada)
PRODUCT MODEL NUMBERS
WGD4700Y, WGD4750X, WGD4800X, WGD4850X, WGD4890X, WGD4900X,
WGD4910X,WGD5100V, WGD5200V, WGD5300V, WGD5500X, WGD5510V,
WGD5550X, WGD5600X, WGD5610X, WGD5700A, WGD5700V, WGD5700X
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow.
29" Wide Models
Dryer Dimensions
27" Wide Models
Dryer Dimensions
43"
(1092 mm)
23¾"
(603 mm)
43"
(1092 mm)
13¾"
(349 mm)
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
Installation Spacing
18"*
(457 mm)
1"
(25 mm)
*Required spacing
29"
(737 mm)
1"
(25 mm)
A
A. Recessed area
B. Side view – closet or conned area
C. Closet door with vents
1"*
(25 mm)
14" max.*
(356 mm)
27¾"
(705 mm)
B
2
48 in.
(310 cm )
24 in.
(155 cm )
*291/2"
(749 mm)
(687 mm)
A
27"
*291/2"
(749 mm)
(687 mm)
B
27"
A. Large opening side-swing door
B. Large opening side-swing door
Installation Spacing
14" max.*
(356 mm)
18"*
48 in.
(310 cm )
2
*
2
(457 mm)
2
*
24 in.
2
(155 cm )
1"
(25 mm)
27"
(686 mm)
A
1"*
1"
(25 mm)
(25 mm)
29
¼"
(743 mm)
B
5½"*
(140 mm)
C
A. Recessed area
B. Side view – closet or conned area
C. Closet door with vents
3"*
(76 mm)
*
2
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, and
oor moldings.
2
*
2
3"*
(76 mm)
C
■ Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
■ Companion appliance spacing should also be considered.
(76 mm)
3"*
(76 mm)
W10115228C
02/2012
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit
are recommended.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
The “Vent System Chart” provides venting requirements that
will help achieve best drying performance.
Vent System Chart
Number of
90° turns or
elbows
0
1
2
3
4
NOTE: Side and bottom exhaust installations for 27" wide
models have a 90º turn inside the dryer. To determine
maximum exhaust length, add one 90º turn to the chart.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Vent System Chart
(29" Wide Long Vent Models Only)
Number of
90° turns
or elbows
0 Rigid metal 120 ft. (36.6 m)
1
2
Type
of vent
Rigid metal
Rigid metal
Box/louvered, or
Angled hoods
110 ft. (33.5 m)
100 ft. (30.5 m)
NOTE: Do not use vent runs longer than those specied
in Vent System Chart. Exhaust systems longer than those
specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
3
4
5
Rigid metal
Rigid metal
90 ft. (27.4 m)
80 ft. (24.4 m)
70 ft. (21.3 m)Rigid metal