30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
WFG540H0A
WFG540H0E
WFG710H0A
WFG714HLA
WFG715H0E
WFG720H0A
Type of Gas
Natural Gas:
■ This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate is located on the
oven frame behind the top right side of the oven door has information
on the types of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different gas
without consulting the serving gas supplier. See “Gas Conversions”
section.
Gas Supply Line
■ Provide a gas supply line if
3
/4" (1.9 cm) rigid pipe to the range
location. A smaller pipe on longer runs may result in insuffient
gas supply. With LP gas, piping or tubing size can be 1/2" (1.3 cm)
minimum. Usually, LP gas suppliers deteremine the size and materials
used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
WFG745H0F
WFG770H0F
PRODUCT DIMENSIONS
A. 277/8" (70.8 cm) max. depth
with handle
B. 36" (91.4 cm) cooktop height
(max.) with leveling legs
screwed all the way in*
A
C. 467/8" (119.1 cm) overall
height (max.) with leveling legs
screwed all the way in*
B
E. 257/16" (64.3 cm) depth.
D. 297/8" (75.9 cm) width
C
Back of range to front of
cooktop**
E
D
F. Model/serial rating plate
(located on the oven frame
behind the top right side of the
oven door)
IMPORTANT: Range must be level after installation. Follow the
instructions in the “Level Range” section. Using the cooktop as a
reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
** Front of door and drawer may extend further forward depending on
styling.
CABINET OPENING DIMENSIONS
used. Do not use TEFLON®† tape.
Flexible metal appliance connector:
■ If local codes permit, a new CSA
B
C
D
design-certified, 4 to 5 ft (122
to 152.4 cm) long, 1/2" (1.3 cm)
or 3/4" (1.9 cm) I.D., flexible metal appliance connector may
be used for connecting range to the gas supply line.
1
■ A
/2" (1.3 cm) male pipe thread is needed for connection to the female
pipe threads of the inlet to the appliance pressure regulator.
■ Do not kink or damage the flexible metal tubing when moving the
range.
■ Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
A
K
F
J
E
L
G
H
I
M
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
B
A. Gas supply line
B. Shutoff valve “open” position
C. To range
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE *.
E. 301/8" (76.5 cm) min. opening width
F. The shaded areas are recommended for installation of rigid gas pipe.
G. 11" (27.6 cm)
†®TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.
Electrical
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required.
A time-delay fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only this range be provided.
H. 17" (43.2 cm)
I. 2" (5.1 cm)
J. 41/2" (11.4)
K. 3" (7.6 cm) min. clearance from both sides of range to side wall or
other combustible material.
L. Grounded outlet
M. Cabinet door or hinges should not extend into the cutout.
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop
depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
IMPORTANT: If installing a range hood or microwave hood combination
above the range, following the range hood or microwave hoods
combination instructions for dimensional clearances above the cooktop
surface.
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is covered by not less than 1/4" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
A freestanding range may be installed next to combustible walls with
zero clearance.
Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Page 1 of 1