30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
WFG515S0E WFG530S0E
Type of Gas
Natural Gas:
•This range is factory set for use with Natural gas. See “Gas Conversions” section. The model/serial rating plate is located on the oven frame behind the top left side of the oven door has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.
Gas Supply Line
•Provide a gas supply line if 3/4" (1.9 cm) rigid pipe to the range location. A smaller pipe on longer runs may result in insuffient gas supply. With LP gas, piping or tubing size can be 1/2" (1.3 cm)
minimum. Usually, LP gas suppliers deteremine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON tape.
Flexible metal appliance connector:
•If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, 1/2" (1.3 cm)
or 3/4" (1.9 cm) I.D., flexible metal appliance connector may be used for
connecting range to the gas supply line.
•A 1/2" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.
•Do not kink or damage the flexible metal tubing when moving the range.
•Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.
PRODUCT DIMENSIONS
|
|
A. 277/8" (70.8 cm) max. depth |
|
|
with handle |
|
|
B. 36" (91.4 cm) cooktop |
|
|
height (max.) with leveling |
|
|
legs screwed all the way in* |
|
|
C. 467/8" (119.1 cm) overall |
A |
|
height (max.) with leveling |
|
|
legs screwed all the way in* |
|
|
D. 297/8" (75.9 cm) width |
F |
B |
C E. 257/16" (64.3 cm) depth. |
|
|
Back of range to front |
|
|
of cooktop** |
|
|
F. Model/serial rating plate |
E |
|
(located on the oven frame |
|
|
behind the top left side of |
D |
|
the oven door) |
IMPORTANT: Range must be level after installation. Follow
the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended.
*Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.
**Front of door and drawer may extend further forward depending on styling.
Electrical
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
B
A
C |
A. Gas supply line |
|
B. Shutoff valve “open” position |
|
C. To range |
†®TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.
CABINET OPENING DIMENSIONS |
|
|
|
|
|
|
|
|
|
|
|
Cabinet opening dimensions shown are for 25" (64.0 cm) |
|
|
|
A.18" (45.7 cm) upper side cabinet to |
|
|
|
|
|
|
|
|
|
|
|
countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) |
|||
countertop |
|
|
|
|
|
|
|
|
|
|
|
countertop height. |
|
|
|
B.13" (33 cm) max. upper cabinet |
|
|
|
|
|
|
|
|
|
|
|
IMPORTANT: If installing a range hood or microwave hood combination |
|||
depth |
|
|
|
|
|
|
|
|
|
|
|
above the range, following the range hood or microwave hoods |
|
|
|
C. 30" (76.2 cm) min. opening width |
|
|
|
|
|
|
|
|
|
|
|
combination instructions for dimensional clearances above |
|
|
|
D.For minimum clearance to top of |
|
|
|
|
|
|
|
|
|
|
|
the cooktop surface. |
|
|
|
cooktop, see NOTE *. |
|
|
|
|
|
|
|
|
|
|
|
A freestanding range may be installed next to combustible walls with |
|||
E. 301/8" (76.5 cm) min. opening width |
|
|
|
|
B |
|
|
|
|
|
D |
zero clearance. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|||||||
F.The shaded areas are recommended |
|
|
|
|
C |
|
|
|
|
|
|
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet |
|||
for installation of rigid gas pipe. |
|
|
|
|
|
|
|
|
|
|
|
is covered by not less than 1/4" (0.64 cm) flame retardant millboard |
|||
|
|
|
|
|
|
|
|
|
|
|
|||||
G.4 1/2" (11.4 cm) |
A |
|
|
|
|
|
|
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) |
|||||||
H.8" (20.3 cm) |
|
|
|
|
|
E |
|
|
|
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. |
|||||
I.17" (43.2 cm) |
|
|
|
|
|
|
|
|
|
|
N |
30" (76.2 cm) minimum clearance between the top of the cooking |
|||
J. 2" (5.1 cm) |
|
|
L |
|
|
M |
|
|
|
platform and the bottom of an uncovered wood or metal cabinet. |
|||||
|
|
|
|
H |
|
|
|
||||||||
K. 41/2" (11.4) |
|
|
|
|
|
|
|
F |
|
|
|
|
|||
|
|
|
G |
|
|
|
|
|
|
|
|
|
|
||
L. 2" (5.1 cm) min. clearance from both |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
F |
|
I |
|
|
|
K |
|
|
|
|
|||
sides of range to side wall or other |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
combustible material. |
|
|
|
|
J |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M.Grounded outlet |
|
|
K |
|
|
|
|
|
|
|
|
|
|
||
N.Cabinet door or hinges should not |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
extend into the cutout. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
Because Whirlpool Corporation includes a continues commitment to improve our products, |
Dimensions are for planning purposes only. For complete details, see |
Ref. W10658550B |
|||||||||||||
we reserve the right to change materials and specifications without notice. |
|
|
|
|
|
|
Installation Instructions packed with product. Specifications subject |
||||||||
|
|
|
|
|
|
|
08/10/15 |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|