DRYER DIMENSIONS
Front view:
7
8
33 / "
(860 mm)
1
2
23 / "
(595 mm)
Condensing Dryer Dimension Guide
Guide de dimensions pour
sécheuse à condensation
PRODUCT MODEL NUMBERS
NUMÉRO DE MODÈLE DU PRODUIT
WCD3090JW WCD5090JW YWCD3090JW0 YWCD5090JW0
Back view:
(100 mm)
Power cord/
cable
34" Max.
(865 mm)
Side view:
5
16
43 / "
(1100 mm)
26"
(655 mm)
27"
(687 mm)
19/32"
(15 mm)
NOTES:
Ƀ Allow clearance behind dryer for proper drain hose routing.
Push dryer back as far as possible and make sure drain
hose is not crushed or kinked.
Ƀ Water can be drained into an alternate location. Remove
the top end of the white hose from the water tank and
install, for example, in a floor standpipe (see “Drain
System”).
W11393170A
19/32"
(15 mm)
Installation spacing for recessed area or closet
installation
All dimensions show recommended and minimum spacing
allowed.
Ƀ Additional spacing should be considered for ease of
installation and servicing.
Ƀ Additional clearances might be required for wall, door,
floor, moldings, and drain system.
Ƀ Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
Ƀ For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Ƀ Electrical outlet placement recommended behind the dryer
and consistent with local code. Consider front and back
clearances when including the cord and plug.
Ƀ Companion appliance spacing should also be considered.
Minimum and recommended installation clearances
(dryer only):
3"
(76 mm)
0"
(0 mm)
48 in.2 min.
(310 cm
Custom under-counter installation:
0" Min.
(0 mm)
34½
(876 mm)
0"Min.
0"Min.
(0 mm)
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile home
construction and Safety, Title 24, HUD Part 280) or
Standard CAN/CSA-Z240 MH.
DRAIN SYSTEM
Drain system can be installed by routing the white hose to
a oor drain, wall standpipe, oor standpipe, or laundry tub
2
)
instead of to the water tank. Select the method you need.
IMPORTANT: To avoid siphoning, only 4.5" (114 mm) of drain
hose should be inside standpipe; do not force excess hose
into standpipe. Always secure drain hose with a cable tie
(not supplied).
0" - 5"*
0"
(0 mm)
0"
(0 mm)
*NOTE: 0"–5"
(0 mm–127 mm)
spacing is allowed
behind dryer, providing
drain hose is not kinked
or pinched.
ELECTRICAL REQUIREMENTS
3"
(76 mm)
24 in.2 min.
(155 cm2)
Floor standpipe drain system
4.5"
4.5"
(114 mm)
(114 mm)
Minimum diameter for a standpipe drain: 2" (51 mm). Top of
standpipe must be at least 30" (762 mm) high; install no higher
than 36" (910 mm) from bottom of dryer.
max. 36"
(910 mm)
min. 30"
(762 mm)
120/240 V, or 120/208 V, 60 Hz AC only on a separate 30 A circuit. Refer to the Owner's Manual for full details.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.