Page 1
Electric Dryer Installation Instructions
Table of Contents
DRYER SAFETY .........................................................................2
INSTALLATION REQUIREMENTS ............................................. 3
Tools and Parts ...................................................................... 3
Location Requirements ......................................................... 4
Electrical Requirements ........................................................ 6
Install Leveling Legs .............................................................. 7
Electrical Connection ............................................................ 8
Venting Requirements .........................................................14
Plan Vent System .................................................................15
Install Vent System ..............................................................16
Connect Inlet Hoses ............................................................ 17
Connect Vent ........................................................................ 18
Level Dryer ........................................................................... 18
COMPLETE INSTALLATION CHECKLIST .............................. 19
DOOR REVERSAL .................................................................... 19
STACKING WASHER AND DRYER ......................................... 19
TROUBLESHOOTING .............................................................. 19
INSTALLATION NOTES
Date of purchase: _________________________________ Date of installation: _______________________________ Installer: ________________________________________ Model number: ___________________________________ Serial number: ___________________________________
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su
producto, visite:
www.whirlpool.com
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad
superior de la puerta.
W10443041B W10443042B-SP
1
Page 2
DRYER SAFETY
IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
2
Page 3
INSTALLATION REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts before starting installation.
Tools needed:
Flat-blade screwdriver #2 Phillips screwdriver
Wire stripper (direct wire installations)
1/4" nut driver (recommended)
Tin snips (new vent installations)
Vent clamps
Parts supplied (all models):
Leveling legs (4)
Parts supplied (steam models):
“Y” connector
Long inlet hose
Short inlet hose
Rubber washer
Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench
Tape measure Pliers
Level
Utility knife
Caulking gun and compound (for installing new exhaust vent)
Parts package is located in dryer drum. Check that all parts are included.
NOTE: If installing dryer on pedestal, do not use leveling legs.
Optional Equipment: (Not supplied with dryer)
Refer to your Use and Care Guide for information about accessories available for your dryer.
Parts needed: (Not supplied with dryer)
Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
3
Page 4
LOCATION REQUIREMENTS
27"
29"
You will need:
■ A location allowing for proper exhaust installation.
See “Venting Requirements.”
■ A separate 30 amp circuit.
■ If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”
■ Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
■ Cold water faucets located within 4 ft. (1.2 m) of the water ll
valves, and water pressure of 20–100 psi (137.9–689.6 kPa). You may use the water supply for your washer using the “Y” connector and short hose (if needed) which are provided.
■ 20–100 psi (138–690 kPa) for best performance.
■ Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.
For each arrangement, consider allowing more space for ease of installation and servicing; spacing for companion appliances and clearances for walls, doors, and oor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.
DRYER DIMENSIONS
Front view:
3
/8"
35
(899 mm)
1"
(25 mm)
Side view:
(736 mm)
Left or
right side
exhaust
7
6
/8"
(174 mm)
(686 mm)
1
/2"
3
(89 mm)
5
1
/8"
(41 mm)
4
Page 5
Door open view:
471/8"
(1197 mm)
1
/8"
48
(1238 mm)
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■ Companion appliance spacing should also be considered.
■ No fuel-burning appliance may be installed in the same
closet as the dryer.
Closet installation (dryer only):
Back view:
Electric
1
6
/4"
(159 mm)
1
/2"
3
(89 mm)
1
28
/8
"
(715 mm)
34" recommended
(864 mm)
18" min.
(457 mm)
4"
(102 mm)
1"
1"
(25 mm)
(25 mm)
Cabinet installation (dryer only):
7"
(178 mm)
3"
(76 mm)
3"
(76 mm)
(460 mm)
48 in.
(310 cm2)
24 in.
(155 cm2)
18"
2
2
14"
(358 mm)
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below 45° F (7° C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times.
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested
spacing of 0" (0 mm) clearance on sides and rear.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, and
oor moldings.
■ Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
4"
(102 mm)
1"
(25 mm)
1"
(25 mm)
5
Page 6
Closet Installation (stacked washer and dryer):
ELECTRICAL REQUIREMENTS
6"
(152 mm)
3"
(76 mm)
3"
(310 cm2)
24 in.
(155 cm2)
1
5
/
2"
(140 mm)
1"
(25 mm)
71"
(1803 mm)
(76 mm)
1"
(25 mm)
Custom under counter installation (dryer only):
39" min.
(990 mm)
48 in.
It is your responsibility:
■ To contact a qualied electrical installer.
■ To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70 – latest edition and all local codes and ordinances.
2
The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park,
2
Quincy, MA 02269.
■ To supply the required 3 or 4 wire, single phase, 120/240
volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
■ Do not use an extension cord.
■ If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
1"
(25 mm)
1"
(25 mm)
NOTE: Some models not recommended for undercounter installation.
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA­Z240 MH.
Mobile home installations require:
■ Metal exhaust system hardware, available for purchase from
your dealer. For further information, see “Assistance or Service” section in your Use and Care Guide.
■ Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.
■ This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
■ If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see “Optional 3-wire connection” section.
■ A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
■ A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
6
Page 7
If your outlet looks like this:
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have 4 10-gauge solid copper wires and match a 4-wire receptacle of
4-wire
receptacle
(14-30R)
NEMA Type 14-30 R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identied by a white cover.
If your outlet looks like this:
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft. (1.22 m) long, must have 3 10-gauge solid copper wires and match a 3-wire receptacle of
3-wire
receptacle
(10-30R)
NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
■ Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with exible metallic conduit. All current-carrying wires must be insulated.
■ 10-gauge solid copper wire (do not use aluminum) at least
5 ft. (1.52 m) long.
INSTALL LEVELING LEGS
Prepare dryer for leveling legs
1.
To avoid damaging oor, use a large at piece of cardboard
from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.
2. Screw in leveling legs
diamond marking
Examine leveling legs, nd diamond marking. Screw legs into leg holes by hand—use a wrench to nish turning legs until diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its nal location. Leave enough room for electrical connection and to connect the exhaust vent.
7
Page 8
ELECTRICAL CONNECTION
Power Supply Cord
Direct Wire
Electrical Connection Options
1. Choose electrical connection type
Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to “Power Supply Cord Connection.”
Power supply cord 3-wire receptacle (NEMA Type 10-30R): Go to “Power Supply Cord Connection.”
4-wire direct connection: Go to “Direct Wire Connection.”
3-wire direct connection: Go to “Direct Wire Connection.”
2. Remove terminal block cover
Before you start, disconnect power. Remove hold-down screw and terminal block cover.
NOTE: If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional External Ground for 3-wire connection.” This connection may be used with either a power supply cord or a direct wire connection.
8
Page 9
POWER SUPPLY CORD CONNECTION
4-WIRE POWER SUPPLY CORD CONNECTION
Power supply cord strain relief:
1. Attach power supply cord strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the two clamp sections (C) together.
2. Attach power supply cord
to strain relief
IMPORTANT: A 4-wire connection is required for moble homes
and where local codes do not permit the use of 3-wire connections.
A
B
C D
4-wire receptacle (NEMA type 14-30R)
Spade terminals with upturned ends
4-prong plug
Ring terminals
1. Prepare to connect neutral ground
wire and neutral wire
Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight t with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
If your outlet looks like this:
Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to “4-Wire Power Supply Cord Connection” on this page.
If your outlet looks like this:
Power supply cord 3-wire receptacle (NEMA Type 10-30R): Go to “3-Wire Power Supply Cord Connection” on page 10.
E
B
A
Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).
2. Connect neutral ground wire and
neutral wire
B
E
C
Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Tighten screw.
9
Page 10
3. Connect ground wire
1. Remove center screw
A
F
Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw.
4. Connect remaining wires
B
Remove center terminal block screw (B).
2. Connect neutral wire
B
C
Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requirements.”
3-WIRE POWER SUPPLY CORD CONNECTION
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
3-wire receptacle (NEMA type 10-30R)
3-prong plug
Connect neutral wire (white or center) (C) of power supply cord to center terminal block screw (B). Tighten screw.
3. Connect remaining wires
Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requirements.”
Spade terminals with upturned ends
10
Ring terminals
Page 11
DIRECT WIRE CONNECTION
Direct wire strain relief
1. Attach direct wire strain relief
4-WIRE DIRECT WIRE CONNECTION
IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections.
1. Prepare your 4-wire cable for
direct connection
A
B
C
Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief (C) through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads.
2. Attach direct wire cable to strain relief
1
"
2
3
(89 mm)
5"
(127 mm)
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 11/2" (38 mm) from remaining 3 wires. Strip insulation back 1" (25 mm). Shape ends of wires into hooks.
1"
(25 mm)
2. Attach hooked wires to terminal
block
Put direct wire cable through the strain relief. The strain relief should have a tight t with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
If your wiring looks like this:
4-wire direct connection: Go to “4-Wire Direct Wire Connection” on this page.
If your wiring looks like this:
3-wire direct connection: Go to “3-Wire Direct Wire Connection” on page 12.
To connect wires to terminal block, place hooked end of wire under terminal block screw, facing to the right, squeeze hooked end together and tighten screw.
3. Prepare to connect neutral ground
wire and neutral wire
E
B
A
Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).
11
Page 12
4. Connect neutral ground wire and
neutral wire
B
E
C
Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw.
5. Connect ground wire
3-WIRE DIRECT WIRE CONNECTION
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
1. Prepare your 3-wire cable for
direct connection
1"
(25 mm)
3½"
(89 mm)
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed.
Strip 31/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks.
A
F
Connect ground wire (green or bare) (F) of direct wire cable to external ground conductor screw (A). Tighten screw.
6. Connect remaining wires
2. Attach hooked wires to terminal
block
To connect wires to terminal block, place hooked end of wire under terminal block screw, facing to the right, squeeze hooked end together and tighten screw.
3. Remove center screw
B
Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requirements.”
12
Remove center terminal block screw (B).
Page 13
4. Connect neutral wire
B
C
Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw.
5. Connect remaining wires
2. Connect neutral ground wire and
neutral wire
B
E
C
Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw.
3. Connect remaining wires
Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requirements.”
OPTIONAL EXTERNAL GROUND FOR 3-WIRE CONNECTION
You must verify with a qualied electrician that this grounding method is acceptable before connecting.
1. Prepare to connect neutral ground
wire and neutral wire
E
B
A
Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).
Place hooked ends of remaining wires under outer terminal block screws (hooks facing right). Tighten screws.
4. Connect external ground wire
A
G
Connect a separate copper ground wire (G) from the external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requirements.”
13
Page 14
VENTING
VENTING REQUIREMENTS
Exhaust hoods:
■ Must be at least 12" (305 mm) from ground or any object that
may obstruct exhaust (such as owers, rocks, bushes, or snow).
Recommended Styles:
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or exible metal vent shall be used for exhausting.
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
■ Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
■ Do not use plastic or metal foil vent.
Rigid metal vent:
■ Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
■ Must be fully extended and supported in nal dryer location.
■ Remove excess to avoid sagging and kinking that may
result in reduced airow and poor performance.
■ Do not install in enclosed walls, ceilings, or oors.
■ The total length should not exceed 7
3
/4 ft. (2.4 m).
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Elbows:
■ 45° elbows provide better airow than 90° elbows.
Recommended Styles:
Good
Better
Clamps:
■ Use clamps to seal all joints.
■ Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.
NOTE: If using an existing vent system, clean lint from
entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or exible metal vents. Review “Vent System Charts” and if necessary, modify existing vent system to achieve best drying performance.
14
Page 15
PLAN VENT SYSTEM
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.
Optional exhaust installations:
If you prefer, dryer may be converted to exhaust out right side, left side (all models except WED9051Y), or through bottom. You must contact your local dealer to have dryer converted. Use 4-Way Exhaust Kit Part Number W10470674.
Over-The-Top installation (also available with one offset elbow)
NOTE: On Model WED9051Y only, do not exhaust out the
left side.
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside.
Periscope installation
Bottom Exhaust installation
15
Page 16
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
■ Use the following “Vent System Charts” to determine type
of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied in “Vent System Charts.” Exhaust systems longer than those specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
The “Vent System Charts” provide venting requirements that will help achieve best drying performance.
Standard Vent System Chart
INSTALL VENT SYSTEM
1. Install exhaust hood
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.
2. Connect vent to exhaust hood
Number of 90° elbows
0
1
2
3
4
Number of 90° elbows
0
1
2
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Long Vent System Chart*
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
130 ft. (39.6 m)
125 ft. (38.1 m)
115 ft. (35.1 m)
129 ft. (39.3 m)
119 ft. (36.3 m)
109 ft. (33.2 m)
Angled
hoods
Vent must t over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.
Angled
hoods
3
4
*For Model WED9051Y only.
NOTE: Bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Rigid metal
Rigid metal
106 ft. (32.3 m)
98 ft. (29.9 m)
100 ft. (30.5 m)
92 ft. (28.0 m)
16
Page 17
CONNECT INLET HOSES
For non-steam models, skip to “Connect Vent” on page 18. The dryer must be connected to the cold water faucet using
the new inlet hoses. Do not use old hoses.
Turn cold water off, remove and
1.
replace rubber washer
Turn cold water faucet off and remove washer inlet hose.
Check and see if rubber washer is in the “Y” connector. Remove old rubber washer from inlet hose and replace with new rubber washer provided.
Attach short hose and
2.
“Y” connector
Attach long hose to “Y”
4.
connector and tighten couplings
One end of the long hose has a wire mesh strainer inside the
coupling. Attach this end to the “Y” connector. Attach washer cold inlet hose to other side of “Y” connector. Screw on coupling by hand until it is seated on connector. Using pliers, tighten the couplings an additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
Attach long hose to dryer ll
5.
valve and tighten coupling
Fig. A
If space permits, attach the brass female end of the “Y” connector to the cold water faucet. See gure A.
If “Y” connector cannot be attached directly to the cold water faucet, the short hose must be used. See gure B. Attach short hose to cold water faucet. Screw on coupling by hand until it is seated on faucet. Then attach “Y” connector to brass male end of the short hose. Screw on coupling by hand until it is seated on connector.
Tighten couplings
3.
Using pliers, tighten the couplings with additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
Fig. B
Attach other end of long hose to ll valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on ll valve connector. Using pliers, tighten the couplings an additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
17
Page 18
Turn on cold water faucet
6.
Check that the water faucets are turned on.
7.
Check for leaks
2.
Move dryer to nal location. Avoid crushing or kinking vent. After dryer is in place, remove cardboard from under dryer.
Move dryer to nal location
LEVEL DRYER
Check for leaks around “Y” connector, faucets, and hoses.
CONNECT VENT
1. Connect vent to exhaust outlet
1.
Check levelness of dryer from side to side. Repeat from
front to back.
NOTE: The dryer must be level for the moisture sensing system
to operate correctly.
Level Dryer
Place
level here
Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must t over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.
18
Not Level LEVEL Not Level
Page 19
2. Adjust leveling legs
If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once legs are level, make sure all four legs are snug against the ground before adjusting them.
COMPLETE INSTALLATION CHECKLIST
Check that all parts are now installed. If there is an extra
q
part, go back through steps to see what was skipped.
Check that you have all of your tools.
q
Dispose of/recycle all packaging materials.
q
Be sure the water faucets are on.
q
Check for leaks around “Y” connector, faucet, and hoses.
q
Check dryer’s nal location. Be sure vent is not crushed
q
or kinked.
Check that dryer is level. See “Level Dryer.”
q
Remove lm on console and any tape remaining on dryer.
q
Wipe dryer drum interior thoroughly with a damp cloth to
q
remove any dust.
Read “Dryer Use” in your Use and Care Guide.
q
For power supply cord installation, plug into a grounded
q
outlet. For direct wire installation, turn on power.
If you live in a hard water area, use of a water softener is
q
recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair.
Select a Time Dry heated cycle, and start dryer. Do not select
q
Air Only Temperature setting.
If dryer will not start, check the following:
•Controlsaresetinarunningor“On”position.
•Startbuttonhasbeenpushedrmly.
•Dryerispluggedintoanoutletand/orelectrical
supply.
•Householdfuseisintactandtight,orcircuitbreaker has not tripped.
•Dryerdoorisclosed.
This dryer automatically runs an installation diagnostic routine at the start of its rst cycle.
NOTE: You may notice an odor when dryer is rst heated. This
odor is common when heating element is rst used. The odor will go away.
DOOR REVERSAL
If you prefer to reverse the door swing on your dryer: A
door reversal kit, Part Number W10277499 is available to order. For further information, see “Assistance or Service” section in your Use and Care Guide.
STACKING WASHER AND DRYER
If you prefer to stack your washer and dryer: A stack
kit, Part Number 8572546 is available to order. For further information, see “Assistance or Service” section in your Use and Care Guide.
TROUBLESHOOTING
See your Use and Care Guide for troubleshooting information.
19
Page 20
W10443041B W10443042B-SP
© 2012 02/12 All rights reserved Printed in U.S.A.
20
Loading...