Whirlpool UXT4230AY, UXT4236AY User Manual

A
g
PRODUCT MODEL NUMBERS
UXT4230AY UXT4236AY
Electrical:
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.
30" (76.2 cm) and 36" (91.4 cm) Range Hood
Installation Clearances
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
7" (17.8 cm) Round Vent System Vent Piece Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
7" (17.8 cm) wall cap 0.0 ft
(0.0 m)
Maximum Recommended Length = 50 ft (15.2 m)
1 - 90° elbow = 5.0 ft (1.5 m) 1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) Length of 7" (17.8 cm) system = 13.0 ft (3.9 m)
VENTING METHODS
Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.
A
g
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
PRODUCT DIMENSIONS
Ref. W10400322C
11/6/12
Example vent system
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft to 7" (17.8 cm) (1.4 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft to 7" (17.8 cm) 90° elbow (1.5 m)
Roof Venting Wal l Ven tin g
B
A
A
C
C
B
7" (17.8 cm) round
90˚ elbow
⁷⁄₈"
(2.2 cm)
4¹⁵⁄₁₆"
(12.5 cm)
⁷⁄₈"
(2.2 cm)
6 ft (1.8 m)
2 ft (0.6 m)
29¹⁵⁄₁₆" (76.0 cm) or 35¹⁵⁄₁₆" (91.0 cm)
6⁹⁄₁₆" (16.7 cm)
1¹⁄₂"
(3.8 cm)
Wall cap
9"
(22.9 cm)
18⁵⁄₈"
(47.3 cm)
1"
(2.5 cm)
. 7" (17.8 cm) round vent
through roof (purchased separately) 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent through the roof (purchased separately)
B. Roof cap with damper
(purchased separately)
C. 18" (45.7 cm) min. to
24" (61.0 cm) max. above the cooking surface
A. 7" (17.8 cm) round vent out the
top and through the wall (purchased separately) 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent through the wall or out the top (purchased separately)
B. Wall cap with damper
(purchased separately)
C. 18" (45.7 cm) min. to
24" (61.0 cm) max. above the
surface
cookin
C
B
D
A
E
. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 18" (45.7 cm) to 24" (61.0 cm) suggested max. - bottom of range
hood to cooking surface
C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm)
models and 36" (91.4 cm) min. cabinet width for 36" (91.4 cm) models
E. 36" (91.4 cm) base cabinet hei
ht