Whirlpool UXT4230ADS User Manual

Range Hood - 30" (76.2 cm) and 36" (91.4 cm)
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
UXT4230AD UXT4236AD
Electrical: A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10646404A
3/14
CABINET OPENING DIMENSIONS
VENTING REQUIREMENTS
A
1 - 90° elbow = 5.0 ft (1.5 m) 1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m)
System length = 13.0 ft (3.9 m)
Maximum Recommended Length
7" (17.8 cm) Round Vent = 50 ft (15.2 m) 3¹⁄₄" x 10" (8.3 x 25.4 cm) = 35 ft (10.7 m)
Rectangular Vent
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
Vent System Vent Piece
90° elbow 5.0 ft
(1.5 m)
3¹⁄₄" x 10" (8.3 cm x 12.0 ft
25.4 cm) flat elbow (3.7 m)
7" (17.8 cm) wall cap 0.0 ft
(0.0 m)
3¹⁄₄" x 10" (8.3 cm x 4.5 ft
25.4 cm) to 7" (17.8 cm) (1.4 m)
3¹⁄₄" x 10" (8.3 cm x 5.0 ft
25.4 cm) to 7" (17.8 cm) (1.5 m) 90° elbow
C
A
D
B
2"
(5.1 cm)
4¹⁵⁄₁₆"
(12.5 cm)
⁷⁄₈"
(2.2 cm)
29¹⁵⁄₁₆" (76.0 cm) or 35¹⁵⁄₁₆" (91.0 cm)
Top Venting Wall Venting
B
A
6⁹⁄₁₆" (16.7 cm) or 9⁹⁄₁₆" (24.4 cm)
A
9"
(22.9 cm)
1¹⁄₂"
(3.8 cm)
(2.5 cm)
18⁵⁄₈"
(47.3 cm)
B
1"
E
A. 18" (45.7 cm) minimum distance from electric cooking surface.
24" (61.0 cm) minimum distance from gas cooking surface.
30" (76.2 cm) suggested maximum above the cooking surface. B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop. C. 30" (76.2 cm) minimum cabinet opening width for 30" (76.2 cm)
models and 36" (91.4 cm) minimum cabinet width for 36"
(91.4 cm) models. D. 12" (30.5 cm) cabinet depth. E. 36" (91.4 cm) base cabinet height.
Example vent system
90˚ elbow
2 ft (0.6 m)
6 ft (1.8 m)
Wall cap
. 7" (17.8 cm) round vent
through roof (purchased separately). 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent through the roof (purchased separately).
B. Roof cap with damper
(purchased separately)
A. 7" (17.8 cm) round vent out
the top and through the wall (purchased separately). 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent through the wall or out the top (purchased separately).
B. Wall cap with damper
(purchased separately)
Loading...