Whirlpool TGZ 3570 IN INSTRUCTION FOR USE

4gb66011b.fm Page 1 Monday, July 14, 2003 4:04 PM
TGZ 3570 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids 2-5. Medium burners 3-6. Large burners
4. Small burner
7. Control knob for front
left burner
8. Control knob for rear, left burner
9. Control knob for central burner
10. Control knob for rear, right burner
11. Control knob for front right burner
Symbols
Operation of burners with safety device and electric ignition
Press the relative knob and turn it anti-clockwise to the large flame and star
setting.
At the same time, hold the knob down until the burner ignites.
After the burner has ignited, keep the knob pressed down for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Shaded circle Large flame and star Small flame
Tap closed Maximum opening/
delivery and electric ignition Minimum opening or reduced delivery
Note:
Should particular local conditions of the
delivered gas make ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting.
The burner safety device shuts off the gas
supply to the burner if the flame goes out accidentally (because of a sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The separator panel, positioned beneath
the cooktop at a minimum distance of 20 mm, must be sealed.
5019 419 66011/B
4gb66011b.fm Page 2 Monday, July 14, 2003 4:04 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and
680 mm, the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. Before installing a hood above the cooktop please refer to the hood instructions, which specify the correct distance.
INJECTORS TABLE CATEGORY II2L3B/P
Type of gas used Type of
NATURAL GAS (Methane) G25
LIQUID PETROLEUM GAS
(Cylinder) G30 LIQUID
PETROLEUM GAS (Cylinder) G31
Type of gas used
G25 25 mbar 5 gas 10.5 1163 l/h 21 G30 30 mbar 5 gas 10.5 763 g/h 21 G31 30 mbar 5 gas 9.45 674 g/h 18.9
burner
large medium small
large medium small
large medium small
Appliance model Total rated heat
Injector marking
132 102
80 87
66 50
87 66 50
Rated heat capacity Pcs-kW
3.00
1.75
1.00
3.00
1.75
1.00
2.7
1.575
0.9
capacity Pcs-kW
Rated consumption
332 l/h 194 l/h 111 l/h
218 g/h 127 g/h
73 g/h
193 g/h 112 g/h
64 g/h
Total rated consumption
Reduced heat capacity Pcs-kW
0.80
0.50
0.50
0.80
0.50
0.50
0.80
0.50
0.50
Gas pressure mbar
min. rat. max.
20 25 30
25 30 35
25 30 35
Air required for burning m
3
/h
Loading...