TGZ 3403 PRODUCT DESCRIPTION SHEET
NL
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner (Sudderbrander)
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Large burner control knob
Symbols
Shaded circle Tap closed
Operation of burners with
electric ignition
To light one of the burners:
• Press the relative knob and turn it
anti-clockwise to the large flame and
star setting .
• At the same time, keep the knob pressed
against the control panel until the burner
ignites.
• Release the knob.
If the burner does not ignite, repeat the
operation.
Large flame
and star
Small flame
Notes:
— Should particular local conditions of the
delivered gas make the ignition of the
burner difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
— Peel the plastic film off the metal knob
insert.
Maximum opening/delivery
and electric ignition
Minimum opening
or reduced delivery
5019 419 61281
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: in case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas
used
NATURAL GAS
Type of gas
used
G25 25 mbar 4 gas 7.70 852 l/h 15.4
Type of
burner
large
medium
small
G25
(Sudderbrander)
Appliance
model
Injector
marking
129
108
76
Total rated
heat capacity
Pcs-kW
Rated
heat
capacity
Pcs-kW
3.00
1.90
0.90
Rated
consumption
332 l/h
210 l/h
100 l/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.26
Gas Pressure
min. rat. max.
20 25 30
Air required for
burning
3
m
/h