Whirlpool LER3622P User Manual

®
Electric Compact Dryer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
LER3622P
Electrical: A four-wire or three-wire, single phase, 120/240-volt, 60-Hz, AC-only, electrical supply (or 120/208-volt electrical supply, if specified on the serial/rating plate) is required on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8577196
08-24-05
23
7
8
(60.6 cm)
"
20
3
4
(52.7 cm)
"
31"
(78.7 cm)
*
)
Closet confined area
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
*Most installations require a
minimum 5¹⁄₂" (14.0 cm) clearance behind the dryer for the exhaust vent with elbows.
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need.
A. Louvered hood style
B. Box hood style
4" (10.2 cm)
4" (10.2 cm)
A
B
4"
(10.2 cm)
2.5"
(6.4 cm)
Recommended hood styles
Angled hood style
is acceptable.
Recessed or closet installation - Dryer only
14" (35.6cm)
18" (45.7cm)
3" (7.6cm)
AB
0"* (0cm)
0"* (0cm)
A. Side view - closet or confined area B. Recessed area
*Additional spacing recommended
Recessed or closet installation - Stacked
12"
(30.5 cm)
12"
(30.5 cm)
0"*
(0 cm)
DRYER
WASHER
0"*
(0 cm)
1" (2.5 cm)
3"
(7.6 cm)
AB
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
Vent system chart
Number of 90º turns or elbows
0 Rigid metal
Type of vent
Flexible metal
2
48 in.
24 in.
2
2
2
(309.7 cm )
(154.8 cm )
C
Box or louvered hoods
36 ft (11 m) 28 ft (8.5 m)
3"
(7.6 cm
3"
(7.6 cm)
Angled hoods
26 ft (7.9 m) 22 ft (6.7 m)
1 Rigid metal
Flexible metal
2 Rigid metal
Flexible metal
26 ft (7.9 m) 18 ft (5.5 m)
16 ft (4.9 m)
8 ft (2.8 m)
16 ft (4.9 m) 12 ft (3.7 m)
6 ft (1.8 m) 2 ft (0.6 m)