ELECTRIC BUILT-IN
SINGLE & DOUBLE OVENS
MODELS (singles):
K ESO- 14OSIl45SIl7OS/176S
SW-1243/2433/1273/2733
M0DEL.S (doubles):
KELI0-240SE/245SS/270SEl276SS
SC02243124431227312743
INSTALLATION
INSTRUCTIONS
INSTALLER: FIMAL CHECK LIST
IMP0 RTANT:
LEAVE THESE INSTRUCTIONS FOR LSE BY LOCAL ELECTRICAL INSPECTOR
PLACEMENT OF UNIT
0 1. Properly positioned-level, aligned and ;quare with cabinet opening.
0 2. Anchored securely to cabinet.
0 3. Installation debris removed.
ELECTRICAL
0 1. Oven properly grounded.
0 2. Separate 120/240 volt or 120/208 voh, 60 hertz, single phase branch of proper
ampacity and protected by a fuse or circuit breaker with approved rating.
0 3. All connections made in accordance with local and/or National Electrical Code.
OPERATIONAL
0 1. Oven racks installed and slide freely ir all positions.
0 2. Knobs securely in place and rotate fre ?ly without rubbing edges of control panel glass
holes.
0 3. All lights function properly.
0 4. Clock timer buzzer operates.
0 5. Doors properly adjusted, open and clcse smoothly.
0 6. Selector switch functions in all modes
0 7. Unless instructed to leave for owner, remove all tags, labels and internal packing
materials.
0 8. Oven has been wiped clean to remove fingermarks and other smudges.
FOR
DETAILED
THANK YOlI INSTALLER:
1. Complete Installat on Check List.
2. Leave all literature for customer.
3. Notify dealer that installation is completed.
INSTRUCTIONS. FOLLOW METHODS
DESCRIBED IN THIS FOLDER.
IMPORTANT: Read Before Installing to Save Time, Work,
assure proper performance,
and owner’s warranty protection.
INSTALLATION INSTRUCTIONS
CABINET CONTRUCTION
The first item for the installation of the oven will be to secure an appropriate cabinet or provide a properly
framed opening in the wall. Refer to Illustration and T;lbles below for the correct location and dimensions
to use. A solid bottom or runners, spaced on 19% cent’?rs are required in the opening to support the oven.
The front of the cabinet must be at right angles to the supports as well as level. If the oven is not
installed level, it will not cook properly.
- 24” to inslde of
cabinet back
SINGLE OVENS
-9 MIN-
Model No.
A
Min. Cabinet
I
B
Min. Cut Out
I
------A
31%”
to
top of
oven support
I
- 24” to inside of
cabinet back
36”
2%” MIN
to upper
cab. doors
%” to lower
cab. doors
.
-A MIN-
-
! I
-
*
-B MIN-
-7
8%”
-
r -,
L’j _-
61 ‘; MI N
Junction Box
/
Furnished by
Ins1
61” MIN
A
taller
KESO-170
KESO-176
SCO-1273
SCO-2733
Model No.
KEDO-240
KEDO-245
SCO-2243
SCO-2443
KEDO-270
KEDO-276
SCO-2273
SCO-2743
27”
DOUBLE OVENS
A
Min. Cabinet
Width
24”
27”
24’/”
B
Min. Cut Out
Width
22%”
24%”
1
,;r
to
top of
oven support
- --
t
-2-