INTGH02X PRODUCT DESCRIPTION SHEET
GB
Removable panstand grids
1.
Medium burners
2-3.
Large burner
4.
Small burner
5.
Medium burner control knob
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Electric ignition button
10.
Symbols
Shaded circle Tap closed
Large flame
Small flame
Maximum opening/
delivery
Minimum opening or
reduced delivery
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame setting .
• At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
• Once the burner is lit, keep the knob pressed
for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operation.
5019 619 01165
Note:
Should particular local conditions of the
-
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
The burner safety system serves to prevent the
-
emission of gas if the flame should be
extinguished accidentally (draughts, interruptions
in gas supply, dousing with liquids, etc.).

DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
INJECTORS TABLE CATEGORY II2H3+
Ty p e of ga s
used
NATURAL GAS
(Methane) G 20
LIQUID
PETROLEUM GAS
(Cylinder) G 30
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Ty p e of ga s
used
G 20 20 mbar 4 gas 7.30 695 l/h 9.52
G 30 28-30 mbar 4 gas 7.30 531 g/h 30.94
G 31 37 mbar 4 gas 7.30 521 g/h 23.80
Ty p e o f
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
Y 115
H2 98
X 72
87
65
50
87
65
50
Rated
heat
capacity
kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
To t al r a t e d
heat capacity
kW
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure (mbar)
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air necessary (m
for the combustion
of 1 m
ELECTRIC SUPPLY: 230 V ~ 50 Hz
3
of gas
3
)