Whirlpool HOB G32 S INSTRUCTION FOR USE

HOB G32 PRODUCT DESCRIPTION SHEET
DE AT
1.
Removable panstand grids
2-5.
Medium burners
3.
Large burner
4.
Small burner
6.
Triple crown burner
7.
Small burner control knob
8. Large burner control knob
9. Triple crown burner control knob
10. Medium burner control knob
11.
Medium burner control knob
Symbols
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, hold the knob down until the burner ignites.
After the burner has ignited, keep the knob pressed down for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Shaded circle
Large flame and star
Small flame
Note:
Should particular local conditions of the delivered gas make ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of a sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The separator panel, positioned beneath the cooktop at a minimum distance of 20 mm, must be sealed.
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
5019 619 53371
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. Before installing a hood above the cooktop please refer to the hood instructions, which specify the correct distance. In case of installation of an oven under the cooktop, please refer to the separate oven instructions.
(DE) CATEGORY II2ELL3B/P
INJECTORS TABLE
Type of gas used
NATURAL GAS (Methane) G20
Type of burner
Tri pl e c ro wn large medium
Injector marking 100/mm
121+59
small
128+64 NATURAL GAS (Methane)* G25
Tri pl e c ro wn large medium
small LIQUID PETROLEUM GAS (Butane / Propane)
G30/G31
Type of gas used
Tri pl e c ro wn
large
medium
small
Appliance model
71+35
G20 20 mbar 5 gas 10.6 1009 l/h 21.2 G25 20 mbar* 5 gas 10.6 1174 l/h 21.2 G30/G31 50 mbar 5 gas 10.6 771 g/h 21.2
*Not supplied in Austria ELECTRIC SUPPLY: 230 V - 50 Hz
Rated heat capacity kW
3.30
128
3.00
94
1.65
76
1.00
3.30
3.00
138
1.65
106
1.00
83
3.30
3.00
79
1.65
58
1.00
46
Total rated heat capacity kW
Rated consumption
314 l/h 286 l/h 157 l/h
95 l/h
365 l/h 332 l/h 183 l/h 111 l/h
240 g/h 218 g/h 120 g/h
73 g/h
Total rated consumption
(AT) CATEGORY II2H3B/P
Reduced heat capacity kW
Gas pressure mbar
min. rat. max.
1.50
0.60
0.35
17 20 25
0.30
1.50
0.60
0.35
18 20 25
0.30
1.90
0.85
0.52
42.5 50 57.5
0.46
Air required for burning m
3
/h
Loading...