HOB G32 PRODUCT DESCRIPTION SHEET
DE AT
1.
Removable panstand grids
2-5.
Medium burners
3.
Large burner
4.
Small burner
6.
Triple crown burner
7.
Small burner control knob
8. Large burner control knob
9. Triple crown burner control knob
10. Medium burner control knob
11.
Medium burner control knob
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, hold the knob down until
the burner ignites.
• After the burner has ignited, keep the knob
pressed down for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Shaded
circle
Large
flame and
star
Small
flame
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught, an
interruption in the gas delivery, boiling over of
liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening
or reduced delivery
5019 619 53371
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions,
which specify the correct distance. In case of installation of an oven under the
cooktop, please refer to the separate oven instructions.
(DE) CATEGORY II2ELL3B/P
INJECTORS TABLE
Type of
gas used
NATURAL GAS
(Methane) G20
Type of
burner
Tri pl e c ro wn
large
medium
Injector
marking
100/mm
121+59
small
128+64
NATURAL GAS
(Methane)* G25
Tri pl e c ro wn
large
medium
small
LIQUID
PETROLEUM
GAS
(Butane / Propane)
G30/G31
Type of
gas used
Tri pl e c ro wn
large
medium
small
Appliance
model
71+35
G20 20 mbar 5 gas 10.6 1009 l/h 21.2
G25 20 mbar* 5 gas 10.6 1174 l/h 21.2
G30/G31 50 mbar 5 gas 10.6 771 g/h 21.2
*Not supplied in Austria
ELECTRIC SUPPLY: 230 V - 50 Hz
Rated heat
capacity
kW
3.30
128
3.00
94
1.65
76
1.00
3.30
3.00
138
1.65
106
1.00
83
3.30
3.00
79
1.65
58
1.00
46
Total rated heat
capacity kW
Rated
consumption
314 l/h
286 l/h
157 l/h
95 l/h
365 l/h
332 l/h
183 l/h
111 l/h
240 g/h
218 g/h
120 g/h
73 g/h
Total rated
consumption
(AT) CATEGORY II2H3B/P
Reduced
heat
capacity kW
Gas pressure mbar
min. rat. max.
1.50
0.60
0.35
17 20 25
0.30
1.50
0.60
0.35
18 20 25
0.30
1.90
0.85
0.52
42.5 50 57.5
0.46
Air required for
burning m
3
/h