Whirlpool HB G10 S INSTRUCTION FOR USE

FRAMTID HGA4K PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids 2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Shaded circle Tap closed
Large flame
Small flame
Maximum opening/ delivery
Minimum opening or reduced delivery
Operation of burners
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame setting .
Once the burner is lit, keep the knob pressed for about 10 seconds.
If the burner fails to light, repeat the above steps.
5019 619 01341
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The burner safety system serves to prevent the
emission of gas if the flame should be extinguished accidentally (draughts, interruptions in gas supply, dousing with liquids, etc.).
HB G10
DIMENSIONS OF COOKTOP AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2L3B/P
Type of gas used Type of
NATURAL GAS
(Methane) G25
LIQUID PETROLEUM GAS
(Butane) G30
(Propane) G31
Type of gas used Model
G25 25 mbar 4 gas 7.30 809 l/h 8,187
G30/G31 30 mbar 4 gas 7.30 531 g/h 30.94
burner
large medium small
large medium small
configuration
Injector marking
F3 126
T8 96
F1 72
87 65 50
Nominal heating capacity kW
Nominal heating capacity kW
3.00
1.65
1.00
3.00
1.65
1.00
Nominal consumption
332 l/h 183 l/h 111 l/h
218 g/h 120 g/h
73 g/h
Total nominal consumption
Reduced h e a t capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
ELECTRIC SUPPLY: 230V ~ 50Hz
Gas Pressure (mbar)
min. nom. max.
20 25 30
25 30 35
Air necessary (m combustion of 1 m
3
) for the
3
of gas
IKEA of Sweden AB SE - 343 81 Älmhult