A 120 Volt, 60Hz., AC only 15-amp fused, electrical supply (or circuit breaker) is required. (A time-delay fuse or circuit breaker is recommended.) It is recommended that a separate circuit serving only this appliance be provided.

Set the grounded 3 prong outlet within the space covered by the decorative flues.

VENTING REQUIREMENTS

OVERALL DIMENSIONS

10¹ ⁄"

8¹ ⁄"

(25.2 cm)

(27.8 cm)

 

7 ⁄" (20 cm)

32" (81.3 cm) min.

46¹⁄"

(117.2 cm) max.

19¹⁄"

(48.4 cm)

Roof Venting

Wall Venting

Non-vented

 

 

A

(recirculating)

 

 

A

 

 

 

5¹⁄"

 

 

 

 

 

 

(12.9 cm)

B

 

B

19⁄"

 

 

30" (76.2 cm)

 

B

(49.8 cm)

 

or

 

 

36" (91.4 cm)

 

 

 

A

 

 

 

CABINET OPENING DIMENSIONS

 

 

 

30" (76.2 cm)

 

 

 

or

 

 

 

36" (91.4 cm)

 

 

 

33 ⁄”

 

 

 

(85 cm)

 

 

 

max.

 

A. Roof cap

A. Wall cap

A. Deflector

 

 

B. 6" (15.2 cm)

B. 6" (15.2 cm)

B. 6" (15.2 cm)

12"

(30.5 cm) min.

round vent

round vent

round vent

14"

(35.6 cm) max.

Calculating Vent System Length

 

To calculate the length of the system you need, add the

 

equivalent feet (meters) for each vent piece used in the system.

 

Vent Piece

6" (15.2 cm) Round

 

45° elbow

2.5 ft

24" (61 cm) min.

30" (76.2 cm) suggested max.

 

(0.8 m)

 

90° elbow

 

5.0 ft

 

 

 

 

 

 

 

 

 

 

 

(1.5 m)

 

 

 

 

3-1/4" x 10" (8.3 cm x 25 cm) vent system

 

 

 

 

3-1/4" x 10”

 

 

 

 

 

 

 

wall

 

 

6 ft. (1.8 m)

 

 

 

 

(8.3 cm x 25 cm)

 

 

 

 

 

 

cap

 

 

 

 

 

elbow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 ft.

 

Maximum length

= 35

ft. (10.7 m)

 

(0.6 m)

 

 

 

 

 

 

 

1 — 90° elbow

= 5.0

ft. (1.5 m)

Note:

 

 

 

 

 

 

 

 

 

 

 

 

8 ft. (2.4 m) straight

= 8.0

ft. (2.4 m)

Flexible vent is

1 — wall cap

= 0.0

ft. (0 m)

Not recommended.

 

 

 

 

 

 

 

 

 

Length of system

 

=13.0 ft. (3.9 m)

 

 

 

 

 

 

 