Whirlpool GZ9730XS, GZ9736XS User Manual

12" (30.5 cm) min. 14" (35.6 cm) max.
30" (76.2 cm)
or
36" (91.4 cm)
33 ⁷⁄₁₆
(85 cm)
max.
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
VENTING REQUIREMENTS
GZ9730XS GZ9736XS
A 120 Volt, 60Hz., AC only 15-amp fused, electrical supply (or circuit breaker) is required. (A time-delay fuse or circuit breaker is recommended.) It is recommended that a separate circuit serving only this appliance be provided.
Set the grounded 3 prong outlet within the space covered by the decorative flues.
30" (76.2cm) and 36" (91.4cm) Wall-Mount Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W100297700A
1-22-08
3-1/4" x 10” (8.3 cm x 25 cm) elbow
wall cap
Maximum length = 35 ft. (10.7 m)
1 — 90° elbow = 5.0 ft. (1.5 m) 8 ft. (2.4 m) straight = 8.0 ft. (2.4 m) 1 — wall cap = 0.0 ft. (0 m)
Length of system =13.0 ft. (3.9 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
3-1/4" x 10"
(8.3 cm x 25 cm) v
ent system
Note: Flexible vent is Not recommended.
®
Calculating Vent System Length
To c a lculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
A. Roof cap B. 6" (15.2 cm)
round vent
A. Wall cap B. 6" (15.2 cm)
round vent
A. Deflector B. 6" (15.2 cm)
round vent
Vent P iece 6" (15.2 cm) Round
45° elbow2.5 ft
(0.8 m)
90° elbow5.0 ft
(1.5 m)
Roof Venting Wall Venting Non-vented
(recirculating)
A
B
B
A
B
A
10¹⁵⁄₁₆"
(27.8 cm)
30" (76.2 cm)
or
36" (91.4 cm)
8¹⁵⁄₁₆"
(25.2 cm)
7⁷⁄₈"
(20 cm)
19¹⁄₁₆"
(48.4 cm)
(81.3 cm) min.
(117.2 cm) max.
5¹⁄₁₆"
(12.9 cm)
19⁵⁄₈"
(49.8 cm)
32"
46¹⁄₈"