Whirlpool GZ7930XH, GZ7936XG, GZ7936XH, GZ7930XG User Manual

PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
GZ7930XG GZ7930XH
GZ7936XG GZ7936XH
Electrical: 120-volt, 60-Hz, AC-only, 15 amp electrical supply. Use copper wire only. A time­delay fuse or circuit breaker and separate circuit is recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8284826 Rev. B
10-20-03
top trim widths 30" vent (76.2 cm) 36" vent (91.4 cm)
3/8" (9.5 mm)
8-1/4" (21 cm) retractable vent height
1-1/2" (3.8 cm)
26-1/8" (66.4 cm)
2-1/8”
(54 cm)
INTERNAL
BLOWER
MOTOR
5/8" (15.9 mm)
4"
(10.2 cm)
8"
(20.3 cm)
9" (22.9 cm)
Diameter
16"
(40.6 cm)
8"
(20,3 cm)
16"
(40.6 cm)
5/8" (15.9 mm)
9-3/8" (23.8 cm)
16"
(40.6 cm)
16"
(40.6 cm)
3-1/4"x 10"
(8.3 cm x 25.4 cm)
27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent
4-1/8"+A (10.5 cm)
17-9/16" (44.6 cm)
17-3/16" (43.7 cm)
A = 1/2" (12.7 mm)
min.
23-9/16" (59.8 cm)
3/8" (9.5 mm)
centerline of cooktop cutout
See cooktop manufacturer’s instructions for cooktop cutout depth and width.
Use dimensions for vent system cutout location that applies to your installation.
Vent system cutout dimensions for internal blower models only. Exterior mounted blower systems connect with 10" (25.4 cm) round vent. The cutout
locations for this vent system will depend upon your specific installation.
Locate power supply junction box at lower right hand rear corner of cabinet.
all cutouts shown are for 3-1/4" x 10" (8.3 cm x 25.4 cm) vent system
Maximum length of vent system
For best performance, use no more than three 90° elbows. If more than one elbow is used, make sure that there is a
minimum of 24" (61 cm) of straight vent
between any two elbows. Do Not install two elbows together. It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 6" (15.2 cm) round vent as soon as possible.
Determining the length of system you need:
To calculate the length of system you need, add the equivalent feet for each vent piece that will be needed. See example for 6" (15.2 cm) round vent system.
Vent Length
6" (15.2 cm) round 35 feet (8.9 m)
3-1/4" x 10" 35 feet (8.9 m) (8.3 cm x 25.4 cm)
®
EXTERIOR-MOUNTED
BLOWER MOTOR
For use with Model No. KPEC992M [900 cfm (25.5 m3/m)]
only