Whirlpool GW395LEG, GW395PEG Dimension Guide

30" Slide-In Gas Range
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
COUNTERTOP PREPARATION CABINET OPENING DIMENSIONS
GW395LEG GW395PEG
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
The cooktop sides of the slide-in range fit over the cutout edge of your countertop.
If you have a square finish (flat) countertop and the opening width is 30-3/8" (77.2 cm), no countertop
preparation is required.
Formed front-edged countertops: Must have molded edge shaved flat 1/4" (0.64 cm) from each front corner of opening.
Tile countertops may need trim cut back 1/4" (0.64 cm) from each front corner and/or rounded edge flattened
.
If countertop opening width is greater than 30-3/8" (77.2 cm), adjust the 1/4" (0.64 cm) dimension.
Countertop must be level. Place level on countertop, first
side to side; then front to back. If countertop is not level, range will not be level. Oven must be level for satisfactory baking conditions.
Cooktop sides of range fit over edges of countertop opening.
Gas supply: Use 3/4" (1.9 cm) rigid pipe gas
supply line to the range location. A smaller size pipe on long runs may result in insufficient gas supply. With L.P. gas, piping or tubing size can be 1/2" (1.3 cm) minimum. If local codes permit, it is recommended that new flexible metal tubing, design-certified by AGA or CSA, 4-5 feet (122-152.4 cm) long, 1/2-inch (1.3 cm) or 3/4-inch (1.9 cm) I.D., be used for connecting the range to the rigid gas supply line. A 1/2" (1.3 cm) male pipe thread is needed for connection to pressure regulator female pipe threads. An individual manual shutoff valve must be located in the same room, but external to the range.
Electrical: 120-volt, 60-Hz, AC-only, 15­ampere, electrical supply, fused on both sides of the line. A separate circuit is recommended. A time-delay fuse or circuit breaker is recommended.
Ref. 9753052
09-17-02
26-7/8"
(68.2 cm)
depth with
handle
36" (91.4 cm) cooktop height with leveling legs lowered 1-1/2 turns
22-1/2"
(57.1 cm)
1"
(2.5 cm)
30-3/4" (78.1 cm) cooktop width
30" (76.2 cm) width
30-7/8" (78.4 cm)
1/4" (0.64 cm)
30-3/8" (77.2 cm) opening width
30" (76.2 cm) min. cabinet opening width
For minimum clearance to the top of the cooktop, see Note.*
18" (45.7 cm) upper cabinet to countertop
9" (22.9 cm)
2"
(51 cm)
2-1/2"
(6.4 cm)
3-3/8" (85.7 cm)
See Note **
10"
(25.4 cm)
6" (15/2 cm)
2-1/2" (6.4 cm)
13" (33 cm) max. upper cabinet depth
30-3/8" (77.2 cm) opening width
Wall outlet to be located within the 18" x 10" (45.7 cm x 25.4 cm) shaded area.
Gas line opening to be located within either 2-1/2" x 24" (6.4 cm x 61 cm) shaded area.
Floor gas line opening if directly below regulator.
** Note
4" (10.2 cm) min. clearance from both sides of range to side wall or other combustible material between upper cabinet and countertop
24"
(61 cm)
7/8" (2.2 cm) min. between cabinet opening and cabinet door or hinge
18"
(45.7 cm)
22-15/32"
(57.1 cm)
®
Loading...