30" Slide-In Gas Range
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
COUNTERTOP PREPARATION CABINET OPENING DIMENSIONS
GW395LEG
GW395PEG
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
The cooktop sides of the slide-in range fit over the cutout
edge of your countertop.
If you have a square finish (flat) countertop and the
opening width is 30-3/8" (77.2 cm), no countertop
preparation is required.
Formed front-edged countertops: Must have molded edge
shaved flat 1/4" (0.64 cm) from each front corner of
opening.
Tile countertops may need trim cut back
1/4" (0.64 cm) from each front corner and/or rounded edge
flattened
.
If countertop opening width is greater than 30-3/8" (77.2
cm), adjust the 1/4" (0.64 cm) dimension.
Countertop must be level. Place level on countertop, first
side to side; then front to back. If countertop is not level,
range will not be level. Oven must be level for satisfactory
baking conditions.
Cooktop sides of
range fit over edges
of countertop
opening.
Gas supply: Use 3/4" (1.9 cm) rigid pipe gas
supply line to the range location. A smaller size
pipe on long runs may result in insufficient gas
supply. With L.P. gas, piping or tubing size can
be 1/2" (1.3 cm) minimum. If local codes
permit, it is recommended that new flexible
metal tubing, design-certified by AGA or CSA,
4-5 feet (122-152.4 cm) long, 1/2-inch
(1.3 cm) or 3/4-inch (1.9 cm) I.D., be used for
connecting the range to the rigid gas supply
line. A 1/2" (1.3 cm) male pipe thread is needed
for connection to pressure regulator female
pipe threads. An individual manual shutoff
valve must be located in the same room, but
external to the range.
Electrical: 120-volt, 60-Hz, AC-only, 15ampere, electrical supply, fused on both sides
of the line. A separate circuit is recommended.
A time-delay fuse or circuit breaker is
recommended.
Ref. 9753052
09-17-02
26-7/8"
(68.2 cm)
depth with
handle
36" (91.4 cm)
cooktop
height with
leveling legs
lowered
1-1/2 turns
22-1/2"
(57.1 cm)
1"
(2.5 cm)
30-3/4" (78.1 cm)
cooktop width
30" (76.2 cm)
width
30-7/8"
(78.4 cm)
1/4"
(0.64 cm)
30-3/8"
(77.2 cm)
opening
width
30" (76.2 cm) min.
cabinet opening
width
For minimum
clearance to the
top of the
cooktop, see
Note.*
18" (45.7 cm)
upper cabinet to
countertop
9"
(22.9 cm)
2"
(51 cm)
2-1/2"
(6.4 cm)
3-3/8"
(85.7 cm)
See Note **
10"
(25.4 cm)
6" (15/2 cm)
2-1/2"
(6.4 cm)
13" (33 cm) max.
upper cabinet depth
30-3/8" (77.2 cm)
opening width
Wall outlet to be
located within the
18" x 10"
(45.7 cm x 25.4 cm)
shaded area.
Gas line opening
to be located within
either 2-1/2" x 24"
(6.4 cm x 61 cm)
shaded area.
Floor gas line
opening if directly
below regulator.
** Note
4" (10.2 cm) min.
clearance from
both sides of
range to side
wall or other
combustible
material between
upper cabinet
and countertop
24"
(61 cm)
7/8" (2.2 cm) min. between
cabinet opening and cabinet
door or hinge
18"
(45.7 cm)
22-15/32"