Whirlpool GU2600XTP, GU2200XTS, GU2500XTP, DU1101XTP, DUL240XTP User Manual

...
Undercounter Dishwasher
®
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
DU1048XTP DU1055XTP DU1055XTS DU1100XTP DU1101XTP DU1145XTP DU1148XTP DUC600XTP DUL240XTP
GU2200XTS GU2300XTS GU2370XTS GU2400XTP GU2455XTS GU2500XTP GU2548XTP GU2600XTP GU2700XTS
Electrical: 120-volt, 60-Hz, AC-only, 15- or 20-amp. fused electrical supply. Use copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended.
Water: A hot water line with 20-120 psi (138-862 kPa) water pressure. Water temperature must be 120°F (49°C) at dishwasher. Use 3/8" O.D. copper tubing with compression fitting or flexible stainless steel braided fill line (1/2" minimum plastic tubing is optional but not recommended). Use a 90° elbow with 3/8" N.P.T. external pipe threads on one end to connect to water inlet valve. Do not solder within 6" (15.2 cm) from water inlet valve.
Drain: Use the new drain hose supplied with your dishwasher. If this is not suitable, use a new drain hose with a maximum length of 12 feet (3.7 m) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the drain connector of the dishwasher. Must have a high drain loop 20 inches (50.8 cm) above the subfloor or floor. Connect drain hose to waste tee or disposer inlet above drain trap in house plumbing and 20 inches (50.8 cm) minimum above the floor. An air gap must be used if the drain hose is connected to house plumbing lower than 20 inches (50.8 cm) above subfloor or floor. Use 1/2" minimum I.D. drain line fittings.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8575348
06-18-07
24-7/8" (64.1 cm)
3/4" (1.9 cm)
insulation – may be
compressed (not used
on all models)
Side view
Rear view
24-1/2"
(62.2 cm)
21" (53.3 cm)
23-7/8"
(60.6 cm)
33-7/8"
(86 cm) min. with
wheels removed
Cut holes in shaded area of cabinet walls or floor as specified below:
water line – 1/2" (1.3 cm)
drain line – 1-1/2" (3.8 cm)
direct wire – 3/4" (1.9 cm)
power supply cord – 1-1/2" (3.8 cm)
* Measured from the lowest point on the underside of countertop. May be
reduced to 33-7/8" (86 cm) by removing wheels from dishwasher.
** Minimum, measured from narrowest point of opening.
*** May be increased to 6-7/8" (17.5 cm) if height of opening is 34-1/2" (87.6 cm)
at its lowest point.
‡ Both sides
9"
(22.9 cm)
10"
(25.4 cm)
6" ***
(15.2 cm)
6" ***
(15.2 cm)
3-1/4"
(8.3 cm)
2-3/4"
(7 cm)
34"
(86.4 cm)
min.*
2"
(5.1 cm)
2"
(5.1 cm)
All surfaces must be free
from intrusions
2"
(5.1 cm)
3-1/4"
(8.3 cm)
3-1/4"
(8.3 cm)
2-3/4"
(7 cm)
3-1/4"
(8.3 cm)
24" (61 cm)
min.
24" (61 cm)
**
5-1/2"
(14 cm)
3-1/2"
(8.9 cm)
Loading...