Gas Dryer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
GGQ8811P
GGQ8821P
LGQ8611P
LGQ8621P
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8562583
09-10-04
43¹⁄₂"
(110.5cm)
*29¹⁄₄"
(74.3cm)
14³⁄₁₆ "
(36cm)
27"
(68.6cm)
For closet installation
with a door, minimum
ventilation openings in
the top and bottom of
the door are required.
Louvered doors with
equivalent air openings
are acceptable.
1. Select the route that will provide the straightest and most direct path outdoors. Plan
the installation to use the fewest number of elbows and turns. When using elbows or
making turns, allow as much room as possible. Bend vent gradually to avoid kinking.
Avoid 90° turns.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent
lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
In the column listing the type of metal vent you are using (rigid metal or flexible metal),
find the maximum length of metal vent on the same line as the number of elbows.
Gas supply: This dryer is equipped for use with
natural gas. It is design-certified by CSA
International for L.P. (propane or butane) gases
with appropriate conversion. When rigid pipe is
used it should be 1/2 inch IPS. When acceptable to
the gas supplier and local codes, 3/8-inch
approved tubing may be used for lengths under 20
feet. For lengths over 20 feet, larger tubing should
be used. Pipe-joint compounds resistant to the
action of L.P. gas must be used. If local codes
permit, it is recommended that new flexible metal
tubing, design-certified by AGA or CSA, be used
for connecting the appliance to the rigid gas
supply line. (The gas pipe which extends through
the lower rear of the appliance has 3/8-inch male
pipe thread.)
A shutoff valve must be installed within 6 feet of
the dryer in accordance with the National Fuel Gas
Code ANSI Z223.1. It is recommended that an
individual manual shutoff valve be installed within
6 feet of the dryer. The location should be easy to
reach for opening and closing.
Electrical: 120-volt, 60 Hz, AC-only, 15 or
20 amp electrical supply is required. (Time-delay
fuse of circuit breaker is recommended.) It is
recommended that a separate circuit serving only
this dryer be provided.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
* Most installations require a minimum
5-1/2” (14 cm) clearance behind the
dryer for the exhaust vent with elbow.
See Installations Instructions, “Venting
Requirements.”
18"
(45.7 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
1"
(2.5 cm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
14" max.
(35.6
29¹⁄₄"
(74.3 cm)
B
cm)
5¹⁄₂"
(14 cm)
2
48 in.
(310 cm )
2
24 in.
(155 cm )
3"
(7.6 cm
2
2
3"
(7.6 cm)
C
4"
Box or
hoods
(10.2 cm)
Angled style
Angled
hoods
58 ft (17.7 m)
28 ft (8.5 m)
48 ft (14.6 m)
23 ft (7 m)
38 ft (11.6 m)
19 ft (5.8 m)
29 ft (8.8 m)
17 ft (5.2 m)
21 ft (6.4 m)
15 ft (4.6 m)
Box hood style
4"
Louvered style
Vent Length Chart
Number of
90° turn s
or elbows
0Rigid metal
1Rigid metal
2Rigid metal
3Rigid metal
4Rigid metal
(10.2 cm)
4"
(10.2 cm)
Typ e of
vent
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Louvered
64 ft (20 m)
36 ft (11 m)
54 ft (16.5 m)
31 ft (9.4 m)
44 ft (13.4 m)
27 ft (8.2 m)
35 ft (10.7 m)
25 ft (7.6 m)
27 ft (8.2 m)
23 ft (7 m)
2.5"
(6.4 cm)