Electrical: 120-volt, 60-Hz, AC-only, 15- or 20-amp. electrical supply. Use copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended.
Exhaust venting: Exhaust your dryer to the outside. four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
Gas Dryer
OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
Closet confined area
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Avoid making 90° turns.
When using elbows or making turns, allow as much room as possible. Bend flexible metal vent gradually to avoid kinking.
Determine vent length
1. See the exhaust vent length chart that matches your type hood for the maximum vent lengths you can use.
Do not use vent runs longer than specified in exhaust vent length charts.
2. Determine the number of elbows you will need.
3. In the column listing the type of metal vent you are using (rigid or flexible), find the maximum length of metal vent on the same line as the number of elbows.
The maximum length using a 2" x 6" rectangular vent with 2 elbows and a 2-1/2" exhaust hood is 8 ft.
3"
3"
48 sq. in.
*
24 sq. in.*
14"
max.
front view
1"
closet
door
* Minimum top and bottom air openings for closet door.
**External exhaust elbow requires additional space.
0"***
0"***
front view
18"
If a closet door is installed: The minimum unobstructed
air openings are required. Louvered doors with equivalent air openings are acceptable.
***Wall, door and floor molding
may require additional spacing.
side view
Recessed
area
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 3405338 Rev. D
01-09-03
4"
**
DOOR CLEARANCE DIMENSIONS
Large side-swing
door (reversible)
17-3/4"
22-3/4"
22-3/4"
7"
Extra-large hamper door
Small side-swing door
15-1/4"
15-1/4"
15-1/4"
13-3/4"
13-3/4"
25-5/8"
8-1/4"
8-3/4"
22-3/4"
22-3/4"
19-1/8"
Super-large
side-swing door (reversible)
3-7/8"
* from floor with dryer feet extended 1 inch
** Most installations will require at least 5-inch clearance
behind the dryer for the dryer vent.
29"
28" max.**
14-1/2"
9-1/4"
6"*
2-1/8"
42-3/8"*
gas burner inlet pipe connection at rear of dryer
dryer exhaust vent
4"
4"
Preferred
Number of Rigid Flexible
90° elbows (fully extended)
When you have a 4" hood
Maximum length of 4"
diameter metal vent
0 1 2 3 4
64 ft. 54 ft. 44 ft. 35 ft. 27 ft.
36 ft. 31 ft. 27 ft. 25 ft. 23 ft.
Acceptable
Number of Rigid Flexible
90° elbows (fully extended)
When you have a 2-1/2" hood
Maximum length of 4"
diameter metal vent
0 1 2 3 4
58 ft. 48 ft. 38 ft. 29 ft. 21 ft.
28 ft. 23 ft. 19 ft. 17 ft. 15 ft.
2-1/2"
Loading...