Whirlpool GCAM2792TQ0, GCAM2792TQ2, GCAM2792TQ3 Installation Guide

IMPORTANT:
Part No, 8524748
Read and save
these instructions
IM PORTANT: Installer: Leave Installation Instructions
with the owner.
Owner: Keep Installation Instructions for
future reference.
electrical inspector's use.
www.coinop.com
COMMERCIAL
WASHER
120-volt, 60-Hz Models
COMMERCIAL LAUNDRY
PRODUCTS
Before you start...
Your safety and the safety of others are very important.
We have provided many important
safety message in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alertsyou to
potentialhazards that can killor
hurtyou and others.
All safety messages will be preceded
by the safety alert symbol and the
word =DANGER" or WVARNING".
These words mean:
Check location where washer will be
installed, Proper installation isyour responsibilily, Make sure you have
everything necessary for correct
installation,
Do Not store or operate washer below 320F (0oC) (some water may remain in washer).
You can be killed or seriously
injured if you don't immediately
follow instructions.
You can be killed or seriously
injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the
instructions are not followed.
Single washer
installations require 12-inch (30 cm)
minimum risers to provide an air
cushion and
prevent noise and
damage to valves,
Grounded electrical outlet
is required, See Electrical
requirements,
Hot and cold water faucets: Must be
within 4 feet (1,2 m) of the back of the washer and provide water
pressure 10 -100 PSI(69-690 kPa), A pressure reduction valve should be used in the supply line where inlet
pressure entering the building exceeds 100 PSI(690 kPa) to prevent damage to the washer mixing valve,
Untape and
open washer
lid, Remove
packages and hoses from
washer,
Front access to the pump area is available by removing 2 clips under the console area and removing the fop and cabinet assembly,
Important: Observe all governing
codes and ordinances.
PAGE 2
Level floor: Maximum slope under washer- 1 inch (2,5 cm),
A floor drain should be
provided under the bulkhead, Prefabricated bulkheads with
electrical outlets, water supply lines and drain facilities should
be used only where local codes permit,
Water heater: Set to deliver 120°F (48,9°C)
water to the washer,
Standpipe drain system: Needs a two-
inch (5 cm) minimum carry-away
capacily of 17 gallons (64,4 liters) per
minute, Top of standpipe must be at least 39 inches (99 cm) high and no
higher than 72 inches (183 cm) from
bottom of washer,
Suppod: Floor must be sturdy enough to support loaded washer weight of 315 pounds (143 kg),
Recessed area instructions
lids washer may be installed in a recessed area or closet.
The installation dimensions shown are the minimum spaces allowable,
Additional spacing should be considered for ease of installation
and servicing, If closet door is
installed, the minimum air openings in top and bottom of door are required,
Louvered doors with air openings in top and bottom are acceptable, Companion appliance spacing
should be considered,
l_inim_ml installation spacing
closet door V
3"
48 sq. in.
(310 cm=)
O
3"
(7.6 cm)
Tools needed for installation:
level
i i flat-blade
J
utility knife sctssom
Parts supplied for installation:
screwdrivel
Electrical requirements
Electrical Shock Hazard
Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adapter.
DO not use an extension cord. Failure to follow these instructions
can result in death, fire, or electrical shock.
Ifcodes pemnitand a separate ground wire isused, it is recommended that a quailied eleclncian determine that the ground path isadequate.
Do Nat greund toa gas pipe. Check with a qualified elecldcian if you are
notsure the washer isproperly grounded. Do Not have a fuse inthe neukal or ground
circuit.
A 120-volt, 60-Hz,AC-only, 15-or
20-ampere fused electrical supply is required, (Time-delay fuse or circuit breaker isrecommended,) Itis recommended that a separate circuit serving only this appliance be provided,
17"
(43.2 cm)
*(0 cm) *(0cm)
48 sq. in.
(155 cm =)
_ I" (2.5 cm) min.
(10.2 cm)
min.
Remove parts from packages, Check
that all parts were included,
1 hose clamp
2 inlet hoses 4 flat water hose washers
2 front-leveling legs with nuts
1drain hose
Grounding instructions
his appliance must be grounded, Inthe event of a malfunction or breakdown,
grounding will reduce the riskof electric shock by providing a path of least
resistance for the electric current, Ynis
appliance is equipped with a cord having an eduipment-greunding conductor and a grounding plug, 1he plug must be plugged into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances,
WARNING - Improper connection at the equipment-greunding conductor con
resultin o dskof elecldc shock. Check with o quoifieq electrician or serviceman ifyou
ore in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appiance - ifit will not fit the ouifet, have a proper outlet installed by a quaifieq electrician.
3-pronp type ougtlet grouna
plug
power supply cord
3-pron ground-
ground
PAGE 3
Now start... IMPORTANT:THISPROCEDUREMUSTBE
Use new hoses and washers that
came with your Whirlpool washer.
Replace inlet hoses after 5 years of
FOLLOWEDTO ASSUREPROPER INSTALLATION.
use to reduce the risk of hose failure, Inspect and replace inlet hoses if
bulges, kinks, cuts, wear, or leaks are
Excessive Weight Hazard
Use two or more people to move
and install washer.
found, When replacing your inlet
hoses, mark the date of replacement
on the label with a permanent
marker,
_droin
_i_ hose
Failure to do so can result in back
or other injury.
==_ stop
coupling washer
m Remove tape that covers
shipping strap, Pull to completely
remove the shipping strap with 2 colterpins from the inside of the washer,
Pull firmly to remove the end of shipping strap from the back of the washer, The shipping strap plug must
be completely removed from the washer for the self-leveling legs to
be released,
Save the shipping strap for use in Step 6.
B Insert a flat washer into each
end of the inlet hoses, Check that washers are firmly seated in couplings,
Inlets are plastic.
Do Not stdp or
crossthread.
cold water inlet vaive
hot water inlet valve
|
) Altach hose to boltom inlet
valve opening first, Then second hose to top inlet, Tighten couplings by
hand; then use pliers to make an
additional two-thirds turn, Slide washer onto cardboard or
hardboard before moving across
floor,
BTO prevent the drain hose from
coming off or leaking, it must be installed per the following instructions:
1,Wet the inside end of the drain
hose with tap water, DO NOT USE
ANY OTHER LUBRICANT.
2, Squeeze ears of clamp with pliers to
open and place clamp over the end of the drain hose,
3, While holding clamp open, work
end of drain hose onto drain connector until drain hose contacts
ribbed stop,
4, Position clamp over the drain hose
area marked "clamp," Release clamp, Clamp should be 1/4 inch (6,4 mm) from end of drain hose,
end of drain hose to
mOpen clamp
secure the rigid and
corrugated sections /
and slide over "hook" (/l
together,
Slide washer onto cardboard or hardboard before moving across
floor to avoid damaging floor covering.
&
) Move washer close to final
position, Put "hook" end of drain hose into laundry tub or standpipe, Check
for proper length of drain hose,
PAGE 4
m Before
aHaching water
inlet hoses, run water through
both faucets into
a bucket, This will
get rid of particles
in water lines that
might clog hoses,
Mark which isthe hot water faucet,
m AHach boHom hose (inlet
marked "H') to hot water faucet, Attach top hose (inlet marked "C') to
cold water faucet, Tighten coupling to faucet by hand; then use pliers to
make final two-thirds turn,
9_11 Stack two corner posts on top of each other, Tiltwasher backwards and
insertcorner posts 3 inches (7,6 cm) infrom one side of washer as shown, Repeat with other corner posts on other side of washer,
1/2"
(1.3 cm)
F
base
t nut
1 U Use legs and nuts from parts
package, Screw nut down to within
1/2 inch (1,3 cm) of base,
13'
! Tilt washer forward raising
back legs 1 inch (2,5 cm) off of floor,
To adjust rear self-leveling legs, gently
lower washer to floor, Check levelness of the washer by placing a
carpenter's level on top of the
washer, first side to side; then front to
back,
\
4. If washer isnot level, adjust
the front legs up or down, Make final check with level,
When washer is level, use wrench
to turn nuts on front legs up tightly against washer base. If nuts ore not tight against washer base, the washer may vibrate.
5• CHECKELECTRICAL
REQUIREMENTS.BESUREYOU HAVE CORRECTELECTRICALSUPPLYAND RECOMMENDEDGROUNDING METHOD.
7 Turn on water faucets and
check for leaks, Tighten couplings if there is leaking, Do Not overtighten; this could cause damage to faucets,
8 Check that you have all of
your tools, Check that the shipping strap was removed from the back of
the washer and used to secure the drain hose,
If entire strop is not removed, washer may vibrate and be noisy.
9• Plug power supply cord into
grounded outlet,
Note: On some models, during factory testing, the timer is advanced padially into the cycle causing the stod button to be depressed, Allow timer to advance to the end of the cycle,
When the cycle iscomplete, the timer
will reset and the stod button will return to the stod position, If the timer
is not allowed to advance to the end of the first cycle and reset, the wash
load will not be completed,
into correct holes at
Insert legs
each front corner of washer until nuts touch washer, Do Not tighten nuts
until Step 14,
2 Tilt washer backward and
remove corner posts, Gently lower
washer to floor,
Move washer to its permanent location. Remove cardboard or
hardboard from under washer.
6 Check that all parts are now
installed, See parts list, Page 3, If there
isan extra part, go back through
steps to see which step was skipped,
PAGE 5
Loading...