Whirlpool G2P HGR/GR, G2P HGR/BK INSTRUCTION FOR USE

G2P HGR PRODUCT DESCRIPTION SHEET
GB IE
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
10.
Electric ignition button
Symbols
Shaded circle Tap closed
Large flame
Small flame
Maximum opening/ delivery
Minimum opening or reduced delivery
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame setting .
a star . The spark plug gives out a spark that causes
the burner to ignite. If the burner does not ignite, press the push­button again.
5019 619 61021/A
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the
correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G 20
NATURAL GAS (Cylinder) G 30
NATURAL GAS (Cylinder) G 31
Type of gas used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of burner
large medium small
large medium small
large medium small
Appliance model
Injector marking
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 l/h 120 l/h
73 l/h
214 l/h 118 l/h
71 l/h
Total rated consumption
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for burning
3
m
/h
Loading...