Whirlpool G2P HG7SR/SS INSTRUCTION FOR USE

G2P HG7 PRODUCT DESCRIPTION SHEET
GB
1.
Removable panstand grids
2-5.
Medium burners
3.
Large burners
4.
Small burner
6.
Double crown burner
7.
Small burner control knob
8.
Large burner control knob
9.
Double crown burner control knob
10.
Medium burner control knob
11.
Medium burner control knob
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise
to the large flame and star setting .
the control panel until the burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
5019 319 54481
Shaded
circle
Large flame
and star
Small flame
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening or
reduced delivery
USING THE DOUBLE-RING BURNER
When using the double-ring burner, leave the
knob on the maximum setting (large flame )
for at least five minutes after lighting before
selecting a lower setting.
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance A between the wall cabinets is between 600 mm and 680 mm, the
height B must be a minimum of 520 mm.
If the distance A between the wall cabinets is greater than the width of the
cooktop, the height B must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL
GAS
(Methane) G20
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31
Type of gas used Appliance model Total rated heat
G20 20 mbar 5 gas 10.6 1009 l/h 21.2
G30 28-30 mbar 5 gas 10.6 771 g/h 21.2
G31 37 mbar 5 gas 10.6 757 g/h 21.2
Type of burner Injector
double crown
large
medium
small
double crown
large
medium
small
double crown
large
medium
small
marking
100/mm
139
128
94
76
92
85
65
50
92
85
65
50
Rated heat
capacity
kW
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
capacity kW
Rated
consumption
314 l/h
286 l/h
157 l/h
95 l/h
240 g/h
218 g/h
120 g/h
73 g/h
236 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
kW
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for
burning m
Electric supply: 230 V - 50 Hz
3
/h
Loading...