4gb66004.fm5 Page 1 Monday, December 17, 2001 3:18 PM
FGZ 5401 |
NL |
PRODUCT DESCRIPTION SHEET |
FGZ 5402 |
|
|
Operation of burners with electric ignition
To light one of the burners:
•Press the relative knob and turn it anticlockwise to the desired setting .
•The spark switch will generate sparks and the burner will light automatically.
•Release the knob.
If the burner does not ignite, repeat the operations described above.
1.Removable panstand grids
2.Medium burner
3.Large burner
4.Simmer burner
5.Medium burner
6. Medium burner control knob
7. Large burner control knob
8. Simmer burner control knob
9. Medium burner control knob
Symbols |
|
|
Shaded |
Tap closed |
|
circle |
||
|
||
Large |
Maximum opening/ |
|
flame |
delivery and electric |
|
and star |
ignition |
|
Small |
Minimum opening or |
|
flame |
reduced delivery |
Note:
-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the
operation with the knob turned to the small flame setting .
5019 419 66004
4gb66004.fm5 Page 2 Monday, December 17, 2001 3:18 PM
DIMENSIONS OF COOKING HOB
AND WORKTOP (mm)
NOTES: if the distance “A“ between the wall cabinets is between 600 mm and 680 mm, the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE |
|
|
|
|
|
|
|
|
CATEGORY I2L |
||||
Type of gas |
Type of |
Injector |
Rated |
Rated |
|
Reduced |
Gas pressure in |
||||||
used |
burner |
marking |
heat |
consump- |
heat |
|
|
Mbar |
|
||||
|
|
|
|
|
capacity |
tion |
|
capacity |
|
|
|
|
|
|
|
|
|
|
|
min. |
rat. |
max. |
|||||
|
|
|
|
|
Pcs-kW |
|
|
|
Pcs-kW |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL |
large |
|
130 |
|
2.90 |
321 l/h |
|
0.49 |
|
|
|
|
|
GAS |
medium |
|
100 |
|
2.00 |
222 l/h |
|
0.33 |
20 |
25 |
30 |
||
(Methane)G 25 |
simmer |
|
67 |
|
0.90 |
100 l/h |
|
0.22 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Type of gas |
Appliance |
|
Total rated |
|
|
Total rated |
|
Air required |
|||||
used |
model |
|
|
heat capacity |
|
consumption |
|
for burning |
|||||
|
|
|
|
Pcs-kW |
|
|
|
|
|
m3/h |
|
||
G 25 25 mbar |
4 gas |
|
|
7.80 |
|
|
865 l/h |
|
15.6 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|