Whirlpool FGZ 5402 IN, FGZ 5402 AR PROGRAM CHART

4gb66004.fm5 Page 1 Monday, December 17, 2001 3:18 PM

FGZ 5401

NL

PRODUCT DESCRIPTION SHEET

FGZ 5402

 

 

Operation of burners with electric ignition

To light one of the burners:

Press the relative knob and turn it anticlockwise to the desired setting .

The spark switch will generate sparks and the burner will light automatically.

Release the knob.

If the burner does not ignite, repeat the operations described above.

1.Removable panstand grids

2.Medium burner

3.Large burner

4.Simmer burner

5.Medium burner

6. Medium burner control knob

7. Large burner control knob

8. Simmer burner control knob

9. Medium burner control knob

Symbols

 

Shaded

Tap closed

circle

 

Large

Maximum opening/

flame

delivery and electric

and star

ignition

Small

Minimum opening or

flame

reduced delivery

Note:

-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the

operation with the knob turned to the small flame setting .

5019 419 66004

Whirlpool FGZ 5402 IN, FGZ 5402 AR PROGRAM CHART

4gb66004.fm5 Page 2 Monday, December 17, 2001 3:18 PM

DIMENSIONS OF COOKING HOB

AND WORKTOP (mm)

NOTES: if the distance “A“ between the wall cabinets is between 600 mm and 680 mm, the height “B” must be a minimum of 520 mm.

If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm.

In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.

INJECTORS TABLE

 

 

 

 

 

 

 

 

CATEGORY I2L

Type of gas

Type of

Injector

Rated

Rated

 

Reduced

Gas pressure in

used

burner

marking

heat

consump-

heat

 

 

Mbar

 

 

 

 

 

 

capacity

tion

 

capacity

 

 

 

 

 

 

 

 

 

 

min.

rat.

max.

 

 

 

 

 

Pcs-kW

 

 

 

Pcs-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

large

 

130

 

2.90

321 l/h

 

0.49

 

 

 

 

GAS

medium

 

100

 

2.00

222 l/h

 

0.33

20

25

30

(Methane)G 25

simmer

 

67

 

0.90

100 l/h

 

0.22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

Appliance

 

Total rated

 

 

Total rated

 

Air required

used

model

 

 

heat capacity

 

consumption

 

for burning

 

 

 

 

Pcs-kW

 

 

 

 

 

m3/h

 

G 25 25 mbar

4 gas

 

 

7.80

 

 

865 l/h

 

15.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 