Whirlpool FGZ 5402 IN, FGZ 5402 AR PROGRAM CHART

4gb66004.fm5 Page 1 Monday, December 17, 2001 3:18 PM
NL
FGZ 5401
PRODUCT DESCRIPTION SHEET
FGZ 5402
1.
Removable panstand grids
2.
Medium burner
3.
Large burner
4.
Simmer burner
5.
Medium burner
6.
Medium burner control knob
7.
Large burner control knob
8.
Simmer burner control knob
9.
Medium burner control knob
Operation of burners with electric ignition
Press the relative knob and turn it anti­clockwise to the desired setting .
The spark switch will generate sparks and the burner will light automatically.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Symbols
Shaded circle
Large flame and star
Small flame
Note:
-
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
Tap closed Maximum opening/
delivery and electric ignition
Minimum opening or reduced delivery
5019 419 66004
4gb66004.fm5 Page 2 Monday, December 17, 2001 3:18 PM
DIMENSIONS OF COOKING HOB
AND WORKTOP (mm)
NOTES: if the distance “A“ between the wall cabinets is between 600 mm and
680 mm, the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas used
NATURAL GAS (Methane)G 25
Type of gas used
G 25 25 mbar 4 gas 7.80 865 l/h 15.6
Type of burner
large medium simmer
Appliance model
Injector marking
130 100
67
Rated heat capacity Pcs-kW
2.90
2.00
0.90
Total rated heat capacity Pcs-kW
Rated consump­tion
321 l/h 222 l/h 100 l/h
Reduced heat capacity Pcs-kW
0.49
0.33
0.22
Total rated consumption
Gas pressure in
Mbar
min. rat. max.
20 25 30
Air required for burning
3
/h
m