Whirlpool EGZ 3402 SW, EGZ 3402-2 SW, EGZ 3402-1 SW PROGRAM CHART

EGZ 3402 PRODUCT DESCRIPTION SHEET
NL
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
Symbols
Shaded circle Tap closed
Large flame Maximum opening/delivery
The control knobs of the cooking hob burners and the electric ignition push­button are on the control panel of the oven.
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame setting .
At the same time, press the push-button with a star . The spark plug gives out a spark that causes the burner to ignite.
If the burner does not ignite, press the push-button again.
Small flame
Star
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
Important
Improper use of the grids can result in damage to the hob: do not position the grids upside down or slide them across the hob.
Do not use: — cast iron griddles or terracotta pots and
pans
heat diffusers such as metal mesh, or any
other types
two burners simultaneously for one
receptacle (e.g. fish kettle).
Minimum opening or reduced delivery
Electric ignition push-button
5019 419 61271
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: in case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas used
NATURAL GAS
Type of gas used
G25 25 mbar 4 gas 7.80 863 l/h 15.6
Type of burner
large medium
G25
small
Appliance model
Injector marking
129 108
78
Total rated heat capacity Pcs-kW
Rated heat capacity Pcs-kW
3.00
1.90
1.00
Rated consumption
332 l/h 210 l/h 111 l/h
Total rated consumption
Reduced heat capacity Pcs-kW
0.60
0.35
0.35
Gas Pressure
min. rat. max.
20 25 30
Air required for burning
3
m
/h
Loading...