Whirlpool CGM2743BQ, CEM2793BQ, CGM2793BQ, CEM2743BQ Installation Instructions Manual

0 (0)
Whi I
COMMERCIAL
LAUNDRY
INSTALLATION INSTRUCTIONS
COMMERCIAL DRYER GAS OR ELECTRIC
MODELSCGM2743BQ CGM2793BQ CEM2743BQ CEM2793BQ
INSTRUCTIONS D'INSTALLATION
MOD]_LESCGM2743BQ CGM2793BQ CEM2743BQ CEM2793BQ
TABLE OF CONTENTS
Page
Dryer Safety ............................................................................. 2
Tools & Parts ........................................................................... 5
Dimensions/Clearances ......................................................... 6
Gas Dryer installation Requirements .................................... 7
Electric Dryer Installation Requirements ........................... 10
Dryer Venting Requirements ............................................... 13
Gas Supply Connection ....................................................... 15
installing Leveling Legs, Coin Slide, and Coin Box ............ 17
Electric Dryer Electrical Connections ................................ 18
Leveling ................................................................................. 22
Complete Installation ........................................................... 23
Reversing Dryer Door Swing ............................................... 24
Changing to a 30- or 60-Minute Timing Cam ..................... 25
Maintenance instructions .................................................... 26
if You Need Assistance ........................................................ 26
TABLE DES MATIERES
Page
S4curit4 de la s4cheuse ...................................................... 28
Outils et pi_ces ................................................................... 31
Dimensions/Distances de d4gagement ........................... 32
Exigences d'installation pour la s4cheuse h gaz ............. 33
Exigences d'installation pour
la s4cheuse 41ectrique ...................................................... 36
Exigences concernant 1'4vacuation
de la s4cheuse .................................................................... 38
Raccordement h la canalisation de gaz ........................... 40
Installation des pieds de nivellement,
de la glissi_re a monnaie et de la caisse
monnaie ............................................................................ 42
Nivellement .......................................................................... 43
Achever PinstaRation ........................................................... 44
inversion du sens d'ouverture de la porte ........................ 45
Installation d'une came de minutage
de 30 ou 60 minutes ............................................................ 46
instructions d'entretien ....................................................... 47
Si vous avez besoin d'assistance ...................................... 47
W10474269A W10474270A = SP
www.whirlpoolcornrnerciallaundry.corn
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately follow instructions,
You can be killed or seriously injured if you don't follow instructions,
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
WARNING - "Ri,kofFi, "
- Clothes dryer installation must be performed by a qualified installer,
- Install the clothes dryer according to the manufacturer's instructions and local codes.
- Do not install a clothes dryer with flexible plastic venting materials or flexible metal (foil type} duct. if flexible metal duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.
- To reduce the risk of severe injury or death, follow all installation instructions.
- Save these instructions.
[] It is recommended that the owner post, in a prominent location, instructions for the customer's use in the event the customer
smells gas. This information should be obtained from your gas supplier.
[] Post the following warning in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
1
2
DRYER SAFETY
WARNING: For your safety, the information in this manual must be followed to minimize !
the risk of fire or explosion, or to prevent property damage, personal injury, or death. J
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO iF YOU SMELL GAS:
= Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building. e Clear the room, building, or area of all occupants. = Immediately carl your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
= if you cannot reach your gas supplier, call the fire department.
- installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA. For more information, contact your gas supplier. If a gas leak is detected, follow the "What to do if you smell gas" instructions.
in the State of Massachusetts, the following installation instructions apply:
[] installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts. [] If using a ball valve, it shall be a T-handle type. [] A flexible gas connector, when used, must not exceed 3 feet.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSi Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
I
3
DRYER SAFETY
IMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic
precautions, including the following:
[] Read all instructions before using the dryer. [] This dryer is intended only for drying clothes and textiles
that have been washed in water. Do not use for any other purpose.
[] WARNING: If you smell gas, do not use the dryer or any
electrical equipment nearby. Warn other people to clear the area. Contact the dryer owner immediately.
[] Do not place items exposed to cooking oils inyour dryer.
Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned
in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, other flammable, or explosive substances as they give off vapors that could ignite or
explode. [] Do not dry unwashed items in the dryer. [] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children. [] Before the dryer is removed from service or discarded,
remove the door to the dryer compartment. [] Do not reach into the dryer if the drum is moving. [] Do not open door while dryer is in operation. It will stop. [] Do not install or store the dryer where it will be exposed
to the weather. [] Do not tamper with controls.
[] Clean dryer lint screen before or after each load. [] Do not use this dryer without the lint screen in place. [] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this Installation Instructions or in published user-repair instructions that you understand and have the skills to carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
[] The final part of a tumble dryer cycle occurs without
heat (cool-down cycle) to ensure that the articles are left at a temperature that ensures that the items will not be damaged.
[] WARNING: Never stop a tumble dryer before the end of
the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated. (Avoids risk of spontaneous combustion).
[] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
[] The interior of the dryer and dryer exhaust vent should be
cleaned periodically by qualified service personnel.
[] See "Electrical Requirements" section for grounding
instructions.
SAVE THESE INSTRUCTIONS
4
TOOLS & PARTS
Tools Needed:
8" (203 mm)
or 10"' (254 ram)
Pipe Wrench
Torx ®_1"=20Security
Screwdriver or Bit
Level
8" (203 mm) or 10" (254 mm)
Adjustable Wrench
that opens to 1" (25 ram)
Flat=Blade Screwdriver
PhiUips Screwdriver
1" (25 ram) Hex-Head
Socket Wrench
5/16" (8 ram) Socket Wrench Pliers (that open to
19/16"[39 mm]}
Utility Knife 1/4" (6 ram) Nut Driver 27"(686 mm)
Wood Block
Caulk Gun and Caulk
(for installing new exhaust vent}
Vent Clamps Pipe-Joint Compound
Suitable for Gas Type
U
Putty Knife
1" (25 ram}
Open=End Wrenches
Ruler or Measuring Tape
Parts Supplied:
Foot Boots (4) Leveling Legs(4) Security Cone
(on some models}
5/16"" Hex Head =
18 x 21/2"' Security Bolt
(on some models}
3=Pin 60=Minute Timing Cam
(on some models}
6=Pin 30=Minute Timing Cam
(on some models}
10 TORX is a registered trademark of Saturn Fasteners, Inc.
5
DIMENSIONS/CLEARANCES
Dimensions
Side View Back View
291/4"
(743 mm)
(648 m m}
ram)
1 "
(25 ram)
I I
u I
101/4''
(260 ram)
Bottom Exhaust
81/4''
(210 mm)
31/4=`
(83 mm)
11/2nn
(38 mm)
51/2''
(140 ram)
_.... (686 ram)
i
i E,oc,.a
(343ram) /
(279 ram)
I"_- 4" dia
| (102 ram)
* 13"| -*
(330 ram) _ 31/4"
(83 ram)
37"
(940 ram)
(gas iodels',
411/4"
ram)
7 ul
(178 ram)
o 6
L I J
_, 141/a''
(359 ram)
Clearances
6
Recessed Front View
l
15"
(381 ram)
F
0 II
.,-- (0 mm)
I Ul
(25 ram)--,-
Closet Side View
4
I u
14"
--- (356 mm)
GAS DRYER INSTALLATION REQUIREMENTS
Location Requirements
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Do not install in a garage. Failure to do so can result in death, explosion, or fire.
Your dryer can be installed in a basement, laundry room, or recessed area.
Companion appliance location requirements should also be considered.
IMPORTANT: Do not install or store the dryer where it will be exposed to the weather. Proper installation is your responsibility.
You will need: [] A grounded electrical outlet located within 6 ft. (1.8 m) of
where the power cord is attached to the back of the dryer. See "Electrical Requirements."
[] A level floor with a maximum slope of 1" (25 mm) under
entire dryer, installing the dryer on soft floor surfaces, such as carpets or surfaces with foam backing, is not recommended.
Gas dryer installation clearances [] The location must be large enough to allow the dryer door to
be fully opened.
[] Additional spacing should be considered for ease of
installation and servicing. The door opens more than 180°.
[] Additional clearances might be required for wall, door, and
floor moldings.
[] Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
When installing a gas dryer: IMPORTANT: Observe all governing codes and ordinances. [] Check code requirements: Some codes limit or do not
permit installation of clothes dryers in garages, closets, or sleeping quarters. Contact your local building inspector.
[] Make sure that lower edges of the cabinet, plus the back
and bottom sides of the dryer, are free of obstructions to permit adequate clearance of air openings for combustion air. See "Recessed Area and Closet installation instructions" below for minimum spacing requirements.
Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet. For
recessed area and closet installations, minimum clearances can be found on the warning label on the rear of the dryer or in "Dimensions/Clearances."
The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and ordinances.
If closet door is installed, the minimum unobstructed air opening in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same closet as the dryer.
48 in?
(310 cm2)
Front View
24 in.2
(155 cm2)
O
Closet
Door
3"
(76 ml
7
GAS DRYER INSTALLATION REQUIREMENTS
Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
iMPORTANT: The dryer must be electrically grounded in
accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition, or Canadian Electrical Code, CSA C22.1. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
[] Do not ground to a gas pipe. [] Do not have a fuse in the neutral or ground circuit. [] A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this dryer be provided.
[] This dryer is equipped with a power supply cord having a
3-prong grounding plug.
[] To minimize the possibility of shock, the cord must be
plugged into a mating, 3 prong, grounding-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician.
[] If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the ground path is adequate.
[] Check with a qualified electrician if you are not sure the
dryer is properly grounded.
Gas Dryer Grounding
GROUNDING iNSTRUCTiONS
=1For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer: This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE iNSTRUCTiONS
8
GAS DRYER INSTALLATION REQUIREMENTS
Gas Supply
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut=off valve, Securely tighten all gas connections. if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram) water column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Observe all governing codes and ordinances. This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1/NFPA 54 or CAN/CSA B149.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Battewmarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this dwer has been certified by CSA International for use at altitudes up to 10,000 feet (3048 m) above sea level at the B.T.U. rating indicated on the model/serial plate. Burner input adjustments are not required when the dwer is operated up to this elevation.
When installed above 10,000 feet (3048 m), a four percent (4%) reduction of the burner B.T.U. rating shown on the model/ serial plate is required for each 1,000 foot (305 m) increase in elevation. For assistance when converting to other gas types and/or installing above 10,000 feet (3048 m) elevation, contact your local service company.
9
ELECTRIC DRYER INSTALLATION REQUIREMENTS
Location Requirements
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Do not install in a garage. FaUure to do so can result in death, e×plosion, or fire.
Your dryer can be installed in a basement, laundry room, or recessed area.
Companion appliance location requirements should also be considered.
iMPORTANT: Do not install or store the dryer where it will be exposed to the weather. Proper installation is your responsibility.
You will need: [] A grounded electrical outlet located within 6 ft. (1.8 m) of
where the power cord is attached to the back of the dryer. See "Electrical Requirements."
[] A level floor with a maximum slope of 1" (25 mm) under
entire dryer. Installing the dryer on soft floor surfaces, such as carpets or surfaces with foam backing, is not
recommended.
Electric dryer installation clearances [] The location must be large enough to allow the dryer door
to be fully opened.
[] Additional spacing should be considered for ease of
installation and servicing. The door opens more than 180°.
[] Additional clearances might be required for wall, door, and
floor moldings.
[] Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
Recessed Area and Closet installation instructions This dryer may be installed in a recessed area or closet. For
recessed area and closet installations, minimum clearances can be found on the warning label on the rear of the dryer or in "Dimensions/Clearances."
The installation spacing is in inches and is the minimum allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and
ordinances.
If closet door is installed, the minimum unobstructed air opening in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
48 in.2
(310 cm2}
Front View
24 in.2
(155 cm2)
0
Closet
Door
3"
(76mr
3 ml
(76into)
Electrical Requirements = U.S.A. only
It is your responsibility: [] To contact a qualified electrical installer. [] To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSVNFPA 70-latest edition and all local codes and ordinances.
[] The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
[] A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
[] To supply the required 3 or 4 wire, single phase, 120/240
volt, 60 Hz., AC only electrical supply (or3 or 4 wire,
120/208 volt electrical supply, if specified on the serial/ rating plate) on a separate 30-amp circuit, fused on both
sides of the line. A time delay fuse or circuit breaker is
recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
[] Do not use an extension cord. [] If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the ground path is adequate.
10
ELECTRIC DRYER INSTALLATION REQUIREMENTS
Electrical Requirements = U.S.A. only (cont.)
Electrical Connection To properly install your dryer, you must determine the type
of electrical connection you will be using and follow the instructions provided for it here.
[] This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
[] If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see "Optional 3-wire connection" section.
[] A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations and (2) areas where local codes prohibit grounding through the neutral conductor.
Electric Dryer Grounding
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.
WARNING: improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Electric Dryer Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief.
Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center
terminal Ground wire (green or bare wire) must be connected to
green ground connector. Connect remaining 2 supply wires to remaining
2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, fire, or
electrical shock.
If using a power supply cord: Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain: [] A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or "U" shaped spade terminals with upturned ends.
[] A UL listed strain relief. if your outlet looks like this:
4-Wire
Receptacle
(14-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
if your outlet looks like this:
3-Wire
Receptacle
(10-30R}
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft. (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
11
ELECTRIC DRYER INSTALLATION REQUIREMENTS
Direct Wire
Fire Hazard
Use 10 gauge copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center
terminal. Ground wire (green or bare wire) must be connected to
green ground connector. Connect remaining 2 supply wires to remaining
2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, fire, or
electrical shock.
if connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be: [] Flexible armored cable or nonmetallic sheathed copper
cable (with ground wire), covered with flexible metallic
conduit. All current-carrying wires must be insulated. [] 10-gauge solid copper wire (do not use aluminum). [] At least 5 ft. (1.52 m) long.
Electrical Requirements = Canada only
!
Electrical Shock Hazard
Plug into a grounded 4 prong outlet. Failure to do so can result in death or electrical shock.
It is your responsibility: [] To contact a qualified electrical installer. [] To be sure that the electrical connection is adequate
and in conformance with the Canadian Electrical Code, C22.1 - latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian
Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
[] To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
[] This dryer is equipped with a CSA International/_
Certified Power Cord intended to be plugged /r, kJ '_
into a standard 14-30R wall receptacle. The _ II II)
cord is 5 ft (1.52 m) in length. Be sure wall \'' _-q ''J receptacle is within reach of dryer's final
location. 4-Wire
Receptacle
(14-30R}
[] Do not use an extension cord.
Ifyou are using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317. For further information, please reference the service numbers located in the "Assistance or Service" section.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
12
DRYER VENTING REQUIREMENTS
Fire Hazard
Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent, Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.
( (),
(102ram)
4" (102 ram) Heavy, Metal Exhaust Vent
[] Only a 4" (102 mm) heavy, metal exhaust vent and clamps
may be used.
[] Do not use plastic or metal foil vent. Rigid metal vent:
[] Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean) [] Must be fully extended and supported in final dryer location. [] Remove excess to avoid sagging and kinking that may result
in reduced airflow and poor performance. [] Do not install in enclosed walls, ceilings, or floors. [] The total length should not exceed 7% ft. (2.4 m). NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review "Vent System Chart" and, if necessary, modify existing vent system to achieve best drying performance.
Elbows:
[] 45 ° elbows provide better airflow than 90 ° elbows.
Bet
Clamps: [] Use clamps to seal all joints. [] Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
13
DRYER VENTING REQUIREMENTS
Vent Hoods
4" (102 ram} Diameter Exhaust Hoods
Box Hood Louvered Hood Angled Hood
Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks, bushes, or snow).
Vent System Length
Maximum Vent Length/Vent Connection Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood.
3. Tighten hose clamp with Phillips screwdriver.
Vent System Chart (Rigid Metal Vent}
No. of Box and Angled
90° Turns Louvered Hood Hood
0 64 ft. (19.5 m) 58 ft. (17.7 m)
1 54 ft. (16.5 m} 48 ft. (14.6 m} 2 44 ft. (13.4 m) 38 ft. (11.6 m) 3 35 ft. (10.7 m) 29 ft. (8.8 m} 4 27 ft. (8.2 m} 21 ft. (8.4 m}
For vent systems not covered by the vent specification chart,
see your parts distributor.
Provision must be made for enough air for combustion and
ventilation. (Check governing codes and ordinances.) See
"Recessed Area and Closet Installation Instructions" in the "Location Requirements" sections.
A 4" (102 mm) outlet hood is preferred. However, a 21/2'' (64 mm) outlet exhaust hood may be used. A 21/2"(64 mm)
outlet creates greater back pressure than other hood types.
For permanent installation, a stationary vent system is required.
Connect Vent
1. If connecting to existing vent, make sure the vent is clean.
2. Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer.
Vent Collar
4. Make sure the vent is secured to exhaust hood with a 4" (102 mm) clamp.
5. Move dryer into final position. Do not crush or kink vent. Make sure dryer is level.
NOTE: Do not remove vent collar.
14
DRYER VENTING REQUIREMENTS
if an Exhaust Hood Cannot be Used
The outside end of main vent should have a sweep elbow directed downward.
l 24" rain.
12" rnin. (610 mm)
(305 rnrn)*
*Minimum clearance above any
accumulation of snow, ice, or debris such as leaves
If main vent travels vertically through the roof, rather than through wall, install a 180 ° sweep elbow on end of vent at least 2 ft. (610 mm) above surface of roof.
The opening in wall or roof shall have a diameter 1/2" (13 mm)
larger than vent diameter. Vent should be centered in opening.
Do not install screening over end of vent for best performance.
Multiple Dryer Venting
A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 5663 I/min. (200 CFM) of air per dryer. Large-capacity lint screens of proper design may be used in main vent if checked and cleaned frequently.
The room where the dryers are located should have make-up
air (air supply) equal to or greater than CFM of all the dryers in
the room.
Back-draft dampers are available from your distributor and
should be installed in the vent of each dryer to keep exhausted
air from returning into dryers and to keep exhaust in balance
within main vent. Unobstructed return air openings are required. Although usually each single-load dryer should have an
unobstructed outdoor air opening of 24 in? (154 cm2)(based on 1 in? [6.5 cm2] per 1,000 Btu [252 kcal]), common make-up air openings are also acceptable. Set up common openings so
the make-up air is distributed equally to all of the dryers. Keep
in mind that the coverage area must be increased by 33% to account for the use of registers or louvers over the openings.
Also, make-up air openings should not be installed near the
location where exhaust vents exit the building.
Each vent should enter the main vent at an angle pointing in the direction of the airflow. Vents entering from the opposite side should be staggered to reduce the exhausted air from
interfering with the other vents.
, l
The maximum angle of each vent entering the main vent should
be no more than 30°.
Keep air openings free of dry cleaning fluid fumes. Fumes
create acids which, when drawn through the dryer heating
units, can damage dryers and items being dried. A clean-out cover should be located on the main vent for
periodic cleaning of the vent system.
GAS SUPPLY CONNECTION
Make Gas Connection
Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
3. Open the shut-off valve in the gas supply line and make sure the dryer has its own gas supply opened.
4. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leaks found.
1. Remove red cap from gas pipe on back of dryer.
2. Connect gas supply to dryer. Use a pipe thread compound approved for the type of gas supplied. If flexible metal tubing is used, be certain there are no kinks.
If necessary for service, depending on model: Open the toe panel by removing the 21/4'' hex-head screws
from the bottom of the panel. Then lift up on the panel while pulling the bottom of the panel away from the dryer. OR
Open the toe panel. Use a putty knife to press on the toe panel lock located at the center top of the toe panel. Pull downward on the toe panel to open. Toe panel is hinged
at the bottom.
15
Loading...
+ 33 hidden pages