Gather the required tools and parts before starting installation.
The parts supplied are in the washer drum.
Tools needed for connecting the water inlet hoses
■ Pliers (that open to
9
⁄16" [39.5 mm])
1
Tools needed for installation
■ Open end wrenches
1/2" and 9/16"
■Torx T-20
®†
Security
screwdriver
■1/4" Nut driver
Parts supplied
AB
■Flashlight (optional)
■Level
■Wood block
■Ruler or measuring tape
C
D
Alternate Parts
Your installation may require additional parts. If you are interested
in purchasing one of the items listed here, call the toll-free number
in the “Assistance or Service” section.
If you haveYou will need to buy
Laundry tub or standpipe
taller than 96" (2.4 m)
Sump pump system (if not already
available)
Overhead sewerStandard 20 gal. (76 L), 30"
(762 mm) tall drain tub or utility sink
and sump pump (available from
local plumbing suppliers)
Floor drainSiphon break, Part Number 285834;
additional drain hose,
Part Number 8318155; and
connector kit, Part Number 285835
Drain hose too short4 ft (1.2 m) drain hose extension kit,
Part Number 285863
Water faucets beyond
reach of ll hoses
2 longer water ll hoses:
6 ft (1.8 m) Part Number 76314
10 ft (3.0 m) Part Number 350008
Accessories
Enhance your washer with these premium accessories.
For more high-quality items or to order, call 1-800-901-2042,
or visit us at www.whirlpool.com/accessories. In Canada call:
1-800-807-6777 or visit us at www.whirlpoolparts.ca.
A. U-shaped hose form
B. Water inlet hoses (2)
C. Inlet hose washers (4)
FE
D. Transit bolt hole plug (4)
E. Beaded tie strap
F. Foam pads
Part NumberAccessory
8212526
31682
1903WH
Washer drip trays, ts under all
All purpose appliance cleaner
Laundry supply storage cart
Options
Pedestal
You have the option of purchasing pedestals separately for this
washer. The pedestal will add to the total height of the washer.
Optional pedestal
Pedestal
Height
7
2
⁄8" (73 mm)47.5" (1207 mm) WhiteWHP0400VW
Approximate
height with washer Color Part Number
4
®† TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
A
B
Location Requirements
Selecting the proper location for your washer improves
performance and minimizes noise and possible washer “walk.”
Your washer can be installed under a custom counter, or in a
basement, laundry room, or recessed area. See “Drain System.”
Companion appliance location requirements should also be
considered. Proper installation is your responsibility.
You will need
■A water heater set to deliver 120°F (49°C) water to the washer.
■A grounded electrical outlet located within 6 ft. (1.8 m) of
where the power cord is attached to the back of the washer.
See “Electrical Requirements.”
■Hot and cold water taps located within 4 ft. (1.2 m) of the hot
and cold water ll valves, and water pressure of 20–100 psi
(137.9–689.6 kPa).
■A level oor with a maximum slope of 1" (25 mm) under entire
washer. Installing the washer on soft oor surfaces, such as
carpets or surfaces with foam backing, is not recommended.
■A sturdy and solid oor to support the washer with a total
weight (water and load) of 400 lbs (180 kg).
Do not operate your washer in temperatures below 32°F (0°C).
Some water can remain in the washer and can cause damage
in low temperatures.
Installation clearances
■The location must be large enough to allow the washer door
to be fully opened.
■ Additional spacing should be considered for ease of
installation and servicing. The door opens more than 90°,
and it is not reversible.
■ Additional clearances might be required for wall, door,
and oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the washer
is recommended to reduce noise transfer.
■Companion appliance spacing should also be considered.
A oor drain should be provided under the bulkhead. Prefabricated
bulkheads with electrical outlets, water inlet lines, and drain facilities
should be used only where local codes permit.
Drain System
The washer can be installed using the standpipe drain system
(oor or wall), the laundry tub drain system, or the oor drain
system. Select the drain hose installation method you need.
See “Tools and Parts.”
Standpipe drain system – wall or oor (views A & B)
The standpipe drain requires a minimum diameter standpipe
of 2" (50 mm). The minimum carry-away capacity can be no less
than 12 gal. (45.5 L) per minute, per washer.
The top of the standpipe must be at least 30" (762 mm) high
and no higher than 96" (2.4 m) from the bottom of the washer.
Washer Dimensions
50 ½"
(1282 mm)
27"
(686 mm)
13
28
(732 mm)
/16"
5
44
/8"
(1134 mm)
30" min.
(762 mm)
Laundry tub drain system
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top
of the laundry tub must be at least 30" (762 mm) above the oor.
30" min.
(762 mm)
5
Floor drain system
The oor drain system requires a siphon break that may be
purchased separately. See “Tools and Parts.”
The siphon break must be a minimum of 28" (710 mm) from
the bottom of the washer. Additional hoses might be needed.
28" min.
(710 mm)
Back view
Electrical Requirements
■A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is recommended that a separate circuit
serving only this washer be provided.
■This washer is equipped with a power supply cord having
a 3 prong grounding plug.
■To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances.
If a mating outlet is not available, it is the personal
responsibility and obligation of the customer to have the
properly grounded outlet installed by a qualied electrician.
■If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
■Do not ground to a gas pipe.
■Check with a qualied electrician if you are not sure
the washer is properly grounded.
■Do not have a fuse in the neutral or ground circuit.
INSTALLATION INSTRUCTIONS
Remove Transport System
IMPORTANT: Position the washer so that the rear of the washer
is within approximately 3 ft. (900 mm) of its nal location.
There are 4 shipping bolts in the rear panel of the washer that
support the suspension system during transportation. These bolts
also retain the power cord inside the washer until the bolts are
removed.
1. Keep the washer in the upright position while removing the
shipping bolts.
Shipping bolt
Shipping bolt
Shipping bolt with plastic spacer
6
2. Using a 1/2" wrench, loosen each of the bolts.
3. Once the bolt is loose, move it to the center of the hole
and completely pull out the bolt, including the plastic spacer
covering the bolt.
3. Using pliers, tighten the couplings with an additional
two-thirds turn.
NOTE: Do not overtighten, use tape, or sealants on the valve.
Damage to the valves can result.
Clear water lines
■Run water through both faucets and inlet hoses, into a
laundry tub, drainpipe, or bucket, to get rid of particles
in the water lines that might clog the inlet valve screens.
■Check the temperature of the water to make sure that the
hot water hose is connected to the hot water faucet and
that the cold water hose is connected to the cold water
faucet.
4. Once all 4 bolts are removed, discard the bolts and spacers.
Then push the power cord plug into the opening on the right
side of the rear panel and pull the power cord through the
opening on the left side of the rear panel and close holes with
the attached cap. Do not pull plug end of power cord through
the right side hole.
5. Close the bolt holes with the 4 transport bolt hole plugs.
NOTE: If the washer is to be transported at a later date, call your
product distributor or installer. To avoid suspension and structural
damage, your washer must be properly set up for relocation
by a trained professional.
Connect the Inlet Hoses
Insert new at washers (supplied) into each end of the inlet
hoses. Firmly seat the washers in the couplings.
AB
A. Coupling
B. Washer
Connect the inlet hoses to water faucets
Make sure the washer drum is empty.
1. Attach a hose to the hot water faucet. Screw on coupling
by hand until it is seated on the washer.
2. Attach a hose to the cold water faucet. Screw on coupling
by hand until it is seated on the washer.
Connect the inlet hoses to the washer
C. Cold water inlet
H. Hot water inlet
1. Attach the hot water hose to the check valve on washer’s
hot (H) water inlet valve. Screw on coupling by hand until
it is seated on the check valve.
2. Attach the cold water hose to the check valve on washer’s
cold (C) water inlet valve. Screw on coupling by hand until
it is seated on the check valve.
3. Using pliers, tighten the couplings with an additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
7
4. Turn on the water faucets completely and check for leaks and
114 mm
at washer connection.
NOTE: Replace inlet hoses after 5 years of use to reduce the
risk of hose failure. Record hose installation or replacement dates
on the hoses for future reference.
Periodically inspect and replace hoses if bulges, kinks, cuts,
wear, or leaks are found.
Connect the Drain Hose
Remove drain hose from washer drum
1. Use locking pliers, squeeze hose clamp tabs together
and insert over the end of drain hose.
Washer drain system can be installed using a oor drain,
wall standpipe, oor standpipe, or laundry tub.
Laundry tub drain or standpipe drain
Connect the drain hose form to the corrugated drain hose.
To keep drain water from going back into the washer:
■ Use the drain hose form, and do not force excess drain hose
into standpipe. Hose should be secure, but loose enough
to provide a gap for air.
■Do not lay excess hose on the bottom of the laundry tub.
Floor drain
You may need additional parts. See Floor drain under
“Tools and Parts.”
2. Slide drain hose onto washer connection.
3. Once drain hose is in place, release pliers.
Secure the Drain Hose
Drain hose must be secured to stop the hose from moving when
water is pumped out. If the drain hose moves, water may end up
on the oor.
1. Drape the power cord over the washer top.
2. Move the washer to its nal location.
3. Place the drain hose in the laundry tub or standpipe as shown.
See illustrations A and B.
114 mm
4½"
(114 mm)
(41/2")
ABC
NOTES:
■Do not force excess drain hose back into the rear
of the washer.
■To avoid siphoning, do not seal or put more than
4½" (114 mm) of the drain hose into drainpipe
or standpipe.
■If the washer faucets and the drain standpipe are
recessed, put the hooked end of the drain hose
in the standpipe as shown. See illustration C.
4½"
(41/2")
(114 mm)
114 mm
4½"
(41/2")
(114 mm)
8
Level the Washer
Properly leveling your washer avoids excessive noise
and vibration.
1. Check the levelness of the washer by placing a level on the
top edge of the washer, rst side to side, then front to back.
If the washer is against a wall, move the washer out slightly
before tipping back. If the washer is not level, rst prop the
front with a wood block and adjust the feet as necessary; then
prop the back and adjust feet as necessary. Repeat this step
until washer is level.
2. Make sure all four feet are stable and resting on the oor.
Then check that the washer is perfectly level (use a level).
3. After the washer is level, use a 9/16" open-end wrench to turn
the nuts on the feet tightly against the washer cabinet.
IMPORTANT: All four feet must be tightened. If the nuts are
not tight against the washer cabinet, the washer may vibrate.
4. The washer should not move front to back, side to side,
or diagonally when pushed on its top edges.
5. Slide the washer to its nal location.
6. Conrm the levelness of the washer.
Complete Installation
1. Check the electrical requirements. Be sure that you have the
correct electrical supply and the recommended grounding
method. See “Electrical Requirements.”
2. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
3. Check that you have all of your tools.
4. Dispose of/recycle all packaging materials.
5. Check that the water faucets are on.
6. Check for leaks around faucets and inlet hoses.
7. Plug into an grounded 3 prong outlet.
8. To test and to clean your washer, measure 1/2 the detergent
manufacturer’s recommended amount of High Efciency (HE)
detergent for a medium-size load. Pour the detergent into
the detergent dispenser. Select any cycle and allow the
washer to complete one whole cycle.
Installing Pad Strips
1. Take the 2 foam pad strips from bag.
2. Remove tape from the back of adhesive pads.
3. Install the pads on the left and right inside walls of the coin
vault, leaving about 1/4" (6 mm) to 1/2" (13 mm) of space
near the front edge of the vault to allow room for the coin box
to lock into position.
A
A. Foam pad strips
9