Whirlpool CEM2940TQ1, CGM2941TQ2, CEM2940TQ0, CGM2941TQ1 Installation Guide

Page 1
INSTALLATIONINSTRUCTIONS
COMMERCIALDRYER
Gas (12(!-Volt,60-Hz) or Electric (12(}/24(}-Volt,60-Hz)
Table of Contents ........................................................ 2
8563800 www,roper.com
Page 2
TABLEOF CONTENTS
DRYER SAFETY ............................................................................ 2
iNSTALLATiON REQUIREMENTS .............................................. 4
Location Requirements .............................................................. 4
Electrical Requirements ............................................................ 6
iNSTALLATiON iNSTRUCTiONS - GAS DRYER .................. 10
install Coin Slide and Coin Box ................................................ 10
Make Gas Connection .............................................................. 10
Connect Vent ............................................................................ 10
Complete Installation .............................................................. 10
iNSTALLATiON iNSTRUCTiONS- ELECTRIC DRYER ........ 11
install Coin Slide and Coin Box ................................................ 11
Make Electrical Connection ...................................................... 11
Connect Vent ............................................................................ 15
Complete Installation .............................................................. 15
CHANGING TO A 30- OR 60=MINUTE TIMING CAM ........... 16
DRYERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
[] it is recommended that the owner post, in a prominent location, instructions for the customer's use in the event the customer smells
gas. This information should be obtained from your gas supplier.
[] Post the following warning in a prominent location.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
I FOR YOUR SAFETY
Page 3
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death. J
= Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
= WHAT TO DO iF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
if you cannot reach your gas supplier, call the fire department.
= installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
In the State of Massachusetts, the following installation instructions apply: [] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T-handle type. [] A flexible gas connector, when used, must not exceed 3 feet.
iMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[]
Read all instructions before using the dryer.
[]
Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry- cleaning solvents, other flammable, or explosive substances as they give off vapors that could ignite or explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment. [] Do not reach into the dryer if the drum is moving. [] Do not install or store the dryer where it will be exposed
to the weather. [] Do not tamper with controls.
Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instruc- tions that you understand and have the skills to carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
[] Clean lint screen before or after each load. [] Keep area around the exhaust opening and adjacent sur-
rounding areas free from the accumulation of lint,dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See installation instructions for grounding requirements.
SAVE THESE iNSTRUCTiONS
iMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSi Z223.1/NFPA 54 or the Canadian Natural Gas and Propane installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA O22.1.
Page 4
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed
[] 8" or 10" pipe wrench [] 8" or 10" adjustable wrench
[] Flat-blade screwdriver [] Phillips screwdriver [] Adjustable wrench that opens to 1" (2.5 cm) or hex-head
socket wrench
[] Level [] 5/16"socket wrench [] Utility knife [] Vent clamps
[] Pipe-joint compound resistant to LP gas [] Caulk gun and caulk (for installing new exhaust vent) [] Pliers
[] Putty knife
Parts supplied Remove parts bag from dryer drum. Check that all parts were
included. [] Wedge cone
[] Dryer foot (4) [] %6"-18 x 21/2'' bolt
[] 3 pin timing cam [] 6 pin timing cam
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
If installing a gas dryer: IMPORTANT: Observe all governing codes and ordinances.
[] Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping quarters. Contact your local building inspector.
[] Make sure that lower edges of the cabinet, plus the back and
bottom sides of the dryer, are free of obstructions to permit adequate clearance of air openings for combustion air. See
"Recessed Area and Closet Installation Instructions" below for
minimum spacing requirements.
NOTE: The dryer must not be installed in an area where it will be exposed to water and/or weather.
Recessed Area and Closet installation instructions
This dryer may be installed in a recessed area or closet. For recessed area and closet installations, minimum clearances can
be found on the serial tag on the dryer. The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and
ordinances. If closet door is installed, the minimum unobstructed air opening
in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.
The dryer must be exhausted outdoors. No other fuel-burning appliance may be installed in the same
closet as the dryer.
Page 5
Minimum Installation Clearances
14" --
(35,6 ore) max,
Product Dimensions 27" (68.6 cm) dryer
"_ 27" (68.6 cm)
15"
(88.1 cm)*
f
o"(0cm)
IM I
c::::::::::::::::::== 0" (Ocrn)
Closet door
__I1 __1/26ore/
Recessed front view
Additional clearances for wall, door and floor moldings may be required or if external exhaust elbow is used.
48 sq,in, (310sq. cm)*
Front
View
24 sq. in. _L
(155 sq. cn_
*Opening is the minimum for a closet door.
Louvered doors with equivalent air openings are acceptable.
O closet
/
door
Product Dimensions 29" (73.7 cm) dryer
_-_29" (73.7 cm) _-_
Closet side view
3" (7.6 cm)
1-1/4"
(3.2cm)
(88.9 cm)
t
(88.6cm) |
BACK VIEW (94cm)
13" , 4" (10.2 cm)
-i_GAS i/ (12"icrn)
i _ETH_ ST ......
29-1/4" (74.3 cm)
,_- 26-1/2" (67.3 cm) -_-
SIDE VIEW
35"
LEFT OR
dia. 4-3/4"
/ ....
/
f I
10-1/4"
37"
non coin opera e
models:
7-1/8" (18.1 cm)
coin-operated
models:
7-7/8" (20 cm)
td-'-
4-3/4"
(12.1. cm)
1 m
I I
BACK VIEW
ELECTRIC1_ ........
(40.6cm)
13" 4" (10.2 cm)
dia.
2k I 2_
18-3/8"_
(46.7 cm)
SIDE VIEW
1-1/4"
_
non-coin-operated
models:
7-1/8" (18.1 cm)
coin-operated
models:
7-7/8" (20 cm)
27-1/4"
(69.2 cm)
1 "
(2.5 cm)
.... _.=
7-1/4"I/! !
(18.4 cm) _=_ I
(35.9 cm)
T
4-1/4"
(10.8 cm)
BOTTOM
EXHAUST
Page 6
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these instructions can result in death,
fire_ or electrical shock.
IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.
The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling
after 1996, and all mobile home installations. If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
[] A four-wire or three-wire, single-phase, 120/240-volt, 60-Hz,
AC-only electrical supply (or four-wire or three-wire,
120/208-volt, if specified on the model/serial rating plate) is required on a separate, 30-amp circuit, fused on both sides of
the line. A time-delay fuse or circuit breaker is recommended.
iMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that
the ground path is adequate. A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
[] A 120-volt, 60-Hz, AC-only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this dryer be provided.
Recommended Ground Method
The dryer, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, latest edition.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and ordinances.
Recommended Ground Method
It is your responsibility to contact a qualified electrical installer to ensure that the electrical installation is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70, latest edition, and all local codes and ordinances.
GROUNDING iNSTRUCTiONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer: This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Page 7
i!!iii,, i:iiiiii (!;z iiFi!!:iiiieqxiiX', !! isesi:
Explosion Hazard
Use a new CSA international approved gas supply line.
Install a shut=off valve. Securely tighten all gas connections. if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
iMPORTANT: Observe all governing codes and ordinances. This installation must conform with all local codes and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas Code ANSI Z223.1/NFPA 54.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
The design of this dryer has been certified by CSA International for use at altitudes up to 10,000 feet (3048 m) above sea level at
the B.T.U. rating indicated on the model/serial plate. Burner input adjustments are not required when the dryer is operated up to
this elevation. When installed above 10,000 feet (3048 m), a four percent (4%)
reduction of the burner B.T.U. rating shown on the model/serial plate is required for each 1,000 foot (305 m) increase in elevation.
For assistance when converting to other gas types and/or installing above 10,000 feet (3048 m) elevation, contact your local
service company.
Gas Supply Line
Recommended method [] Provide a gas supply line of rA" rigid (IPS) pipe to the dryer
location. Pipe joint compounds that resist the action of LP gas must be used. Do not use TEFLON _ tape. With LP gas, piping or tubing size can be 1/2"minimum. Usually, LP gas
suppliers determine the size and materials used in the system.
Alternate method [] The gas supply may also be connected using 3/s"approved
copper or aluminum tubing. Ifthe total length of the supply line is more than 20 feet (6.1 m), larger tubing will be required.
If using natural gas, do not use copper tubing. Pipe joint
compounds that resist the action of LP gas must be used.
Flexible metal appliance connector: [] It is recommended that a new flexible stainless steel gas line,
design-certified by CSA International, be used for connecting the dryer to the gas supply line. (The gas pipe which extends
through the lower rear of the dryer is provided with 3/s"male pipe thread.)
[] Do not kink or damage the flexible stainless steel gas line
when moving the dryer.
Rigid pipe connection: The rigid pipe connection requires a combination of pipe fittings
to obtain an in-line connection to the dryer.
[][]Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve installed within 6 ft. (1.8 m) of dryer in accordance with
National Fuel Gas Code, ANSI Z223.1. This valve should be
located in the same room as the dryer. It should be in a location that allows ease of opening and closing. Do not block
access to shutoff valve. The valve is for turning on or shutting off gas to the dryer.
B
Type of Gas
This dryer is equipped for use with natural gas. It is design- certified by CSA International for L.R (propane and butane) gases
with appropriate conversion. No attempt shall be made to convert the dryer from the gas specified on the serial/rating plate for use
with a different gas without consulting the serving gas supplier. Conversion must be done by a qualified service technician. Gas
conversion kit part numbers are listed on the gas valve burner base.
A. Gas supply line
B. Shutoff valve "open" position
C. To dryer
Installed in a confined area: Ifthe dryer is installed in a confined area such as a bathroom
or closet, provision must be made for enough air for combustion and ventilation. Check governing codes and
ordinances or refer to the "Recessed Area and Closet
Installation Instructions" in the "Location Requirements"
section.
t®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
7
Page 8
GasSupply Pressure Testing
A 1/s"NPT minimum plugged tapping, accessible for gauge testing, must be installed immediately upstream of the gas supply
connection to the dryer. The dryer must be disconnected from the gas supply piping
system during any pressure testing of the system at test pressures in excess of 1/2psig.
Fire Hazard
Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
Plan installation to use the fewest number of elbows and turns.
ExhaustAirFlow A.Better B.Good
Allow as much room as possible when using elbows or making turns. Bend vent gradually to avoid kinking.
Vent outlet is located at the center of the bottom dryer back. The vent can be routed up, down, left, right, behind the dryer or
straight out the back of the dryer.
Vent System Length
Maximum length of vent system depends upon the type of vent used, number of elbows and type of exhaust hood. The maximum
length for both rigid and flexible vent is shown in the chart.
Maximum Vent Length
4" (10.2 cm) Diameter Exhaust Hoods
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. [] The dryer vent must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
[] Do not use an exhaust hood with a magnetic latch. [] Do not install flexible metal vent in enclosed walls, ceilings or
floors. [] 4" (10.2 cm) heavy metal vent and clamps must be used. [] Use clamps to seal all joints. Vent must not be connected or
secured with screws or other fastening devices which extend
into the interior of the vent. Do not use duct tape.
IMPORTANT: Observe all governing codes and ordinances. Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent crushing and kinking.
Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow and poor performance.
An exhaust hood should cap the vent to prevent rodents and insects from entering the home or business.
Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes).
If using an existing vent system, clean lint from the entire length of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal or flexible metal vent.
Rigid Metal Vent
No. of 90° turns Box Hood and Louvered Style Angled Hood Style
O 1
2 3 4
Flexible Metal Vent
No. of 90° turns Box Hood and Louvered Style Angled Hood Style
0 36 ft, (11.0 m) 28 ft. (8,5 m) 1 31 ft, (9,4 m) 23 ft. (7.0 m) 2 27 ft, (8,2 m) 19 ft. (5.8 m) 3 25 ft, (7,6 m) 17 ft. (5.2 m) 4 23 ft, (7.0 m) 15 ft. (4.6 m)
64 ft. (19.5 m) 58 ft. (17.7 m) 54 ft, (16.5 m) 48 ft, (14.6 m)
44 ft, (13,4 m) 38 ft, (11.6 m) 35 ft, (10,7 m) 29 ft, (8.8 m) 27 ft, (8.2 m) 21 ft. (6.4 m)
For vent systems not covered by the vent specification chart, see Whirlpool Service Manual, "Exhausting Whirlpool Dryers," Part
No. LIT603197, available from your Whirlpool parts distributor. If dryer is installed in a confined area, such as a bedroom,
bathroom or closet, provision must be made for enough air for combustion and ventilation. (Check governing codes and
ordinances.) See "Recessed Area and Closet Installation Instructions" in the "Location Requirements" section.
A four-inch outlet hood is preferred. However, a 21/2'' (6.4 cm) outlet exhaust hood may be used. A 21/2''(6.4 cm) outlet creates
greater back pressure than other hood types. For permanent installation, a stationary vent system is required.
Page 9
Multiple Dryer Venting
[] A main vent can be used for venting a group of dryers. Main
vent should be sized to remove 200 CFM of air per dryer.
Large-capacity lint screens of proper design may be used in
the main vent if checked and cleaned frequently. The room
where the dryers are located should have make-up air equal
to or greater than the CFM of all the dryers in the room. [] Back-draft Damper Kits, Part No. 3391910, are available from
your Whirlpool dealer and should be installed in each dryer's
vent to prevent exhausted air from returning into the dryers
and to keep the exhaust in balance within the main vent.
Unobstructed air openings are required.
Each vent should enter the main vent at an angle pointing in the direction of the airflow. Vents entering from the opposite side
should be staggered to reduce the exhausted air from interfering with the other vents.
The maximum angle of each vent entering the main vent should be no more than 30°.
if an exhaust hood cannot be used: The outside end of the main vent should have a sweep elbow
directed downward. If the main vent travels vertically through the roof, rather than through the wall, install a 180° sweep elbow on
the end of the vent at least 2 feet (61 cm) above the highest part of the building. The opening wall or roof shall have a diameter 1A"
(1.3 cm) larger than the vent diameter. The vent should be centered in the opening.
s C
A.Exhausthoodorelbow
B.WallC.Maincollectorvent
D. Horizontalvent
/_'_ E Verticalvent
E
E. t80°sweepelbow
°.........( .Roo
............I I _ _t. (61 crn)rain, above
air flow _ B -,_--
A.Individualdryervent
B.Main vent
Keep air openings free of dry cleaning fluid fumes. Fumes create acids which, when drawn through the dryer heating units, can
damage dryers and loads being dried. A clean-out cover should be located on the main vent for periodic
cleaning of the vent system.
_ _ highest point of building
Do not install screening or cap over the end of the vent.
Page 10
INSTALLATIONINSTRUCTIONS- GASDRYER
The console houses the factory-installed accumulator timer with actuating arm and button.
The timer installed is set to provide 45 minutes (4 pins) of drying time when activated by the coin slide. Timer cams for 30-minute
(6 pins) and 60-minute (3 pins) drying times are included in the parts bag.
The coin-slide mechanism, control panel lock and key, and coin- box lock and key are not included and are available from usual
industry sources.
Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
NOTE: Slide dryer onto cardboard or hardboard before moving to
avoid damaging floor covering. f. Using two or more people, move dryer to desired installation
location.
2. Take tape off front corners of dryer. Open dryer and remove
the literature and parts packages. Wipe the interior of the
drum thoroughly with a damp cloth.
3. Take two of the cardboard corners from the carton and place
them on the floor in back of the dryer. Firmly grasp the body
of the dryer and gently lay it on its back on the cardboard
corners.
4. With one of the legs in hand, check the ridges for a diamond
marking. That's how far the leg is supposed to go into the
hole.
5. Start to screw the leveling legs into the holes by hand. (Use a
small amount of liquid detergent to lubricate the screw
threads so it is easier to turn the legs.) Use a 1-inch wrench or
socket wrench to finish turning the legs until you reach the
diamond mark.
Now stand the dryer up.
6. Remove the service door of the meter case by lifting it up at
the back. Install the money-accepting device. (Refer to
manufacturer's instructions for proper installation.)
f. Remove red cap from gas pipe.
2. Connect gas supply to dryer. Use pipe-joint compound resistant to the action of L.R gas for gas connections. If
flexible metal tubing is used, be certain there are no kinks.
3. Open the shutoff valve in the gas supply line.
4. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.
f. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into final position. Do not crush or kink vent. Make sure dryer is level.
3. Check to be sure there are no kinks in the flexible gas line.
With dryer in final position place level on top of the dryer, first side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter,
Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
For dryers using coin slides, use adapter kit supplied with dryer.
7=
Replace the meter case service door. Put the coin vault with lock and key in the meter case opening.
8.
Remove cardboard or hardboard from under dryer.
10
2=
Plug into a grounded 3 prong outlet.
3.
Check dryer operation (some accumulated time may be on the timer due to factory testing).
Insert coins in slide and press slide in slowly. (Operating time
will accumulate per number of coins and type of timing cam used.) Push START/RESTART button. Using a full heat cycle
(not the air cycle), let the dryer run for at least five minutes.
Dryer will stop when time is used up. NOTE: Dryer door must be closed for dryer to operate. When
door is open, dryer stops, but timer continues to run. To restart dryer, close door and push START/RESTART button.
Page 11
4. Iftheburnerdoesnotigniteandyoucanfeelnoheatinside thedryer,shutoffdryerforfiveminutes.Checkthatallsupply
valvecontrolsarein"ON"positionandthattheelectricalcord ispluggedin.Repeatfive-minutetest.
5. Ifdryingtimeistoolong,makesurelintscreenisclean.
INSTALLATIONINSTRUCTIONS- ELECTRICDRYER
The console houses the factory-installed accumulator timer with actuating arm and button.
The timer installed is set to provide 45 minutes (4 pins) of drying time when activated by the coin slide. Timer cams for 30-minute (6 pins) and 60-minute (3 pins) drying times are included in the
parts bag.
For dryers using coin slides, use adapter kit supplied with
dryer.
7. Replace the meter case service door. Put the coin vault with lock and key in the meter case opening.
8. Remove cardboard or hardboard from under dryer.
The coin-slide mechanism, control panel lock and key, and coin- box lock and key are not included and are available from usual
industry sources.
Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
NOTE: Slide dryer onto cardboard or hardboard before moving to
avoid damaging floor covering. t. Using two or more people, move dryer to desired installation
location.
2. Take tape off front corners of dryer. Open dryer and remove the literature and parts packages. Wipe the interior of the
drum thoroughly with a damp cloth.
3. Take two of the cardboard corners from the carton and place them on the floor in back of the dryer. Firmly grasp the body
of the dryer and gently lay it on its back on the cardboard corners.
4. With one of the legs in hand, check the ridges for a diamond marking. That's how far the leg is supposed to go into the hole.
5. Start to screw the leveling legs into the holes by hand. (Use a small amount of liquid detergent to lubricate the screw
threads so it is easier to turn the legs.) Use a 1-inch wrench or socket wrench to finish turning the legs until you reach the
diamond mark. Now stand the dryer up.
6. Remove the service door of the meter case by lifting it up at the back. Install the money-accepting device. (Refer to
manufacturer's instructions for proper installation.)
Power Supply Cord Method
This dryer is manufactured with the neutral ground wire connected to the neutral (center) of the wiring harness at the
terminal block. If local codes do not permit this type of connection, use "Four-wire connection" instructions.
Use a new UL-listed power supply cord rated 240-volt min., 30-amp and marked for use with a clothes dryer.
Fire Hazard
Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief,
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections. Failure to do so can result in death, fire, or
electrical shock.
t. Disconnect power.
11
Page 12
2. Remove hold-down screw and the terminal block cover.
....J
A. External ground conductor screw B. Tab
C. Terminalblock cover D. Hold-down screw
Power Supply Cord, Four-wire electrical connection:
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground wire from the external ground conductor screw.
Fasten under center, silver-colored
terminal block screw.
7. Connect the ground wire of the power supply cord to the external ground
B C D
conductor screw. Tighten screw.
8. Connect the neutral wire (white or center) of the power supply cord under the center
screw of the terminal block. Tighten
screw.
¢
A.Spadeterminalswithupturnedends E
B.Neutral C.3/4"UL-listedstrainrelief
D.Neutral(white) E. Ringterminals
F. Groundwire
9. Connect the other wires to outer terminal
block screws. Tighten screws.
t0. Tighten strain relief screws. t 1. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover with hold-down screw.
G.Groundprong
Four-wire power supply cord must have four, No.-10 copper wires and match a four-wire receptacle of NEMA Type 14-30R. The
fourth wire (ground conductor) must be
identified by a green cover and the neutral conductor by a white cover.
3=
Assemble 3/4"UL-listed strain relief (UL marking on strain relief) into the hole below the terminal block opening. Tighten
strain relief screws just enough to hold the two clamp sections together. Install power supply cord/cable through the strain relief.
A. Strain relief clamp sections B. Dryer cabinet
C. Strain relief screws
4=
Complete installation following instructions for your type of electrical connection:
Four-wire (recommended method)
Three-wire (if four-wire is not available)
A. External ground conductor screw B. Appliance neutral ground wire
C. Center terminal block screw D. Outer terminal block screws E. Strain relief screw
F. Neutral (center wire) G. Ground wire
12
Page 13
Power Supply Cord, Three=wire electrical connection:
Thisbladeconnectedto B
.....thisconductor. ........................
E D C
A. Spade terminals with upturned ends
B. Ring terminals C.Neutral (white or center)
D. 3/4"UL-listed strain relief E. Neutral
Three-wire power supply cord must have three, No.-10 copper wires and
match a three-wire receptacle of NEMA Type 10-30R.
Use this method where local codes permit connecting
neutral ground wire to neutral wire: A ....................
5. Loosen or remove the center terminal F-'__
block screw. F ......
Connect the neutral wire (white or center) of the power supply cord to the center,
silver-colored terminal screw of the
0
terminal block. Tighten screw.
7. Connect the other wires to outer terminal
8. Tighten strain relief screws. block screws. Tighten screws. _ C
9. Insert tab of the terminal block cover into D............
slot of the dryer rear panel. Secure cover with hold-down screw.
Use this method where local codes do not permit connecting neutral ground wire to neutral wire:
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground wire from the external ground conductor
screw. Connect the appliance neutral ground wire and the neutral wire (white or
center) of the power supply cord under the center, silver-colored terminal block
screw. Tighten screw.
7. Connect the other wires to outer terminal block screws. Tighten screws.
8. Tighten strain relief screws.
9. Insert tab of the terminal block cover into slot of the dryer rear panel. Secure cover
with hold-down screw.
t0. After reattaching the terminal cover,
connect a separate copper ground wire from the external ground conductor screw
to an adequate ground.
If codes permit and a separate ground wire is used, it is recommended that a qualified
electrician determine that the ground path is adequate.
E ............
A. External ground conductor screw
B.Center terminal block screw
C.Outer terminal block screws D. Strain relief screw E. Neutral (center wire)
F.Appliance neutral ground wire
A. Separate copper ground wire B. Extemat ground conductor screw
C. Appliance neutral ground wire D. Center terminal block screw
E. Outer terminal block screws F. Strain relief screw
G. Neutral (center wire)
I_] _
13
Page 14
Fire Hazard
Use 10 gauge solid copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver). Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct wire cable must match power supply (4-wire or 3-wire) and be:
[] Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.
[] 10-gauge solid copper wire (do not use aluminum). [] At least 5 ft. (1.52 m) long.
j b
A. Extemat ground conductor screw B. Tab
C. Terminalblock cover D. Hold-down screw
3=
Install 3/4"conduit connector into the hole below the terminal block opening. Connect flexible metallic conduit and tighten connector screw. Install direct wire cable through the flexible
metallic conduit.
_- j
A. Conduit connector B. Dryer cabinet
C. Connector screw
4=
Complete installation following instructions for your type of electrical connection:
Four-wire (recommended method) Three-wire (if four-wire is not available)
Direct Wire, Four=wire electrical connection:
A I 1" (2.5 ore) 4_
1o I strippedof / _-_
disconnect I insulation |
': I ofwires //
ofwires into ahook,
Shapeends
A. _4" conduit connector B. Neutral (white or center)
C. Ground wire (green or bare) D. tO-gauge, 3 wire with ground wire in
'_ 31/2' (8.9 cm) _1
Strip 5" (12.7 cm) of outer covering
from end of cable. Leave green or bare
ground wire at 5" (12.7 cm). Cut 1½" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2,5 cm).
flexible metallic conduit
14
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground wire from the external ground conductor
screw. Fasten under center, silver- colored terminal block screw.
7. Connect the ground wire (green or bare) of the direct wire cable to the external
ground conductor screw. Tighten screw.
8. Place the hooked end of the neutral wire (white or center) of the direct wire cable
under the center screw of the terminal block (hook facing right). Squeeze hook
end together. Tighten screw.
9. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hook facing right). Squeeze hooked ends together. Tighten
screws.
fO. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover with hold-down screw.
D
A. External ground conductor screw B. Appliance neutral ground wire
C. Center terminal block screw D. Outer terminal block screws
E. Neutral (center wire) F. Green or bare ground wire
Page 15
Direct Wire,
Three=wire electrical connection:
Three wire with ground wire: green or bare
wire cut short. Wire is not used. Dryer is grounded through neutral conductor.
A
ofwires
to stripped of
disconnect insulation
box
Use this method where local codes permit connecting neutral ground wire to
neutral wire:
5. Loosen or remove the center terminal block screw.
6. Place the hooked end of the neutral wire
(white or center) of the direct wire cable
under the center screw of the terminal block (hook facing right). Squeeze
hooked end together. Tighten screw.
7. Place the hooked ends of the other
direct wire cable wires under the outer terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
8. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover with hold-down screw.
c
A. Extemat ground conductor screw B. Center terminal block screw
C. Outer terminal block screws D. Neutral (center wire)
E.Appliance neutral ground wire
c
Strip 31/2" (8.9 cm) of outer covering from end of cable. Strip
of wires into
_ Shapeends
a hook.
A. _4" conduit connector B. Neutral (white or center)
C. tO-gauge, 3 wire with ground wire in
flexible metallic conduit
insulation back 1" (2.5 cm). If using 3 wire cable with ground wire, cut green or bare wire even with outer covering.
Use this method where local codes do
not permit connecting neutral ground wire to neutral wire:
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground wire
from the external ground conductor screw. Connect the appliance neutral ground wire
and the neutral wire (white or center) of the direct wire cable under the center, silver-
colored terminal block screw. Tighten screw.
7. Connect the other wires to outer terminal block screws. Tighten screws.
8. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover with hold-down screw.
9. After reattaching the terminal cover,
connect a separate copper ground wire from the external ground connector screw
to an adequate ground.
If codes permit and a separate ground wire is used, it is recommended that a qualified
electrician determine that the ground path is adequate.
A...........Ii C
A. Separate copper ground wire B. External ground conductor screw C. Appliance neutral ground wire
D. Center terminal block screw E. Outer terminal block screws
t_ Neutral (center wire)
t. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into final position. Do not crush or kink vent. Make sure dryer is level.
With dryer in final position place level on top of the dryer, first side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
2. Plug in dryer or reconnect power.
3. Check dryer operation (some accumulated time may be on the timer due to factory testing).
Insert coins in slide and press slide in slowly. (Operating time
will accumulate per number of coins and type of timing cam used.) Push START/RESTART button. Using a full heat cycle
(not the air cycle), let the dryer run for at least five minutes.
Dryer will stop when time is used up. NOTE: Dryer door must be closed for dryer to operate. When
door is open, dryer stops, but timer continues to run. To restart dryer, close door and push START/RESTART button.
4. If drying time is too long, make sure lint screen is clean.
5. Now start the dryer and allow it to complete a full heat cycle (not air cycle) to make sure it is working properly.
15
Page 16
CHANGINGTOA30-OR60-MINUTETIMINGCAM
Electrical Shock Hazard
Disconnect power hefore making cam changes. Failure to follow these instructions can result in death
or electrical shock.
You can install the 30-minute or 60-minute timing cam (shipped with dryer) as follows:
t. Unplug dryer or disconnect power.
2. Unlock meter case.
3. Turn the timing cam by hand until the V-shaped notch lines up below the ratchet tooth.
4. Insert a narrow, flat-blade screwdriver under the timing cam near the clock shaft. Gently lift cam straight up and off shaft
making sure that the V-shaped notch clears the ratchet tooth.
5=
Place new cam (hub side down) over clock shaft. Line up flat
side of shaft with flat side of cam hole. Check that drive lug is in place.
A. Ratchet tooth B. Timing cam
C. Drive lug
6. Turn cam until V-shaped notch lines up with ratchet tooth.
7. Press cam down in place on clock shaft. Make sure that V-shaped notch clears the ratchet tooth.
8. Close and lock the meter case.
9. Plug in dryer or reconnect power.
Maintenance instructions:
[] Clean lint screen after each cycle. [] Removing accumulated lint:
[] From inside the dryer cabinet:
Lint should be removed every 2 years or more often, depending on dryer usage. Cleaning should be done by a
qualified person.
[] From the exhaust vent:
Lint should be removed every 2 years, or more often, depending on dryer usage.
If dryer does not operate check the following: [] Electric supply is connected.
[] Circuit breakers are not tripped or fuses are not blown. [] Door is closed.
[] Controls are set in a running or "ON" position. [] START button has been pushed firmly. [] For gas dryers, check that gas supply shutoff valves are set in
open position.
If you need assistance:
The Commercial Laundry Support Center will answer any
questions about operating or maintaining your dryer not covered in the installationinstructions. The Commercial Laundry Support
Center is open 24 hours a day, 7 days a week. Just dial 1-800 NO BELTS (1-800-662-3587) -- the call is toll free.
When you call, you will need the dryer model number and serial number. Both numbers can be found on the serial-rating plate
located in the dryer door well.
8563800
© 2005.
AIIrightsreserved.
06/2005
Printedin U.S.A.