Whirlpool CEE2760KQ, CGE2761KQ Installation Instructions

Installation Instructions
IMPORTANT: Read and save these instructions
IMPORTANT Installer: Leave Installation Instructions
with the owner.
Owner: Keep Installation Instructions for
Save Installation Instructions for local
electrical inspector’s use.
COMMERCIAL DRYER
GAS
Part No. 8527809
COMMERCIAL LAUNDRY PRODUCTS
®
www.whirlpool.com
120-volt, 60 Hz
ELECTRIC
120/240-volt, 60 Hz
Page 2
Post, in a prominent location, instructions to be followed in the event the user smells gas. The information posted shall be obtained by consulting with the local gas supplier.

Before you start...

We have provided many important safety message in this manual and on your appliance. Always read and obey all safety messages.
WARNING
This is the safety alert symbol. This symbol alerts you to
potential hazards that can kill
or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean:
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
You can be killed or seriously injured if you don’t immediately follow instructions.
You can be killed or seriously injured if you don’t follow instructions.
D ANGER
Your safety and the safety of others are very important.
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (45.8 cm) above the floor for a garage installation.
Failure to do so can result in death, explosion, or fire.
— Do not store or use gasoline,
or other flammable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
WARNING
Observe all governing codes and ordinances.
Check code requirements: Some codes
limit or do not permit installation of clothes dryers in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
Comply with the installation specifications and dimensions.
Consider spacing requirements for companion appliances.
Make sure you have everything necessary for proper installation.
Properly install dryer. Contact a qualified installer to insure that
the electrical and gas installations meet all national and local codes and ordinances.
Exhaust to outdoors: Dryer must be exhausted outdoors to prevent exposure to harmful substances in the gas fuels.
Note: The dryer must not be installed in an area where it will be exposed to water and/or weather,
It is your responsibility to:

If installing a GAS dryer:

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
IMPORTANT SAFETY INSTRUCTIONS
WARNING — To reduce the risk of fire, electric shock, or injury to persons when using your appliance, follow basic precautions, including the following:
1. Read all instructions before using the
appliance.
2. Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances, as they give off vapours that could ignite or explode.
3. Do not allow children to play on or in the appliance. Close supervision of children is necessary when the appliance is used near children.
4. Before the appliance is removed from service or discarded, remove the door to the drying compartment.
5. Do not reach into the appliance if the drum is moving.
6. Do not install or store this appliance where it will be exposed to the weather.
7. Do not tamper with controls.
8. Do not repair or replace any part of
the appliance or attempt any servicing unless specifically recommended in the user­maintenance instructions or in published user-repair instructions that you understand and have the skills to carry out.
9. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
10. Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
11. Clean lint screen before or after each load.
12. Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
13. The interior of the appliance and exhaust duct should be cleaned periodically by qualified service personnel.
14. Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
SAVE THESE INSTRUCTIONS
• Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be
done by a qualified installer, service agency or the gas supplier.
Post the following in a prominent location.
MAXIMUM LENGTH OF 4-INCH (10.2 cm) DIAMETER
RIGID METAL VENT
No.
of 90°
turns
EXHAUST HOOD TYPE
2-1/2" (6.4 cm)
4"
(10.2 cm)
4"
(10.2 cm)
4"
(10.2 cm)
4"
(10.2 cm)
4"
(10.2 cm)
64 FT. (19.5 m) 54 FT. (16.5 m) 44 FT. (13.4 m) 35 FT. (10.7 m) 27 FT. (8.2 m)
64 FT. (19.5 m) 54 FT. (16.5 m) 44 FT. (13.4 m) 35 FT. (10.7 m) 27 FT. (8.2 m)
0 1 2 3 4
58 FT. (17.7 m) 48 FT. (14.6 m) 38 FT. (11.6 m) 29 FT. (8.8 m) 21 FT. (6.4 m)
MAXIMUM LENGTH OF 4-INCH (10.2 cm) DIAMETER
FLEXIBLE METAL VENT
36 FT. (11.0 m) 31 FT. (9.4 m) 27 FT. (8.2 m) 25 FT. (7.6 m) 23 FT. (7.0 m)
36 FT. (11.0 m) 31 FT. (9.4 m) 27 FT. (8.2 m) 25 FT. (7.6 m) 23 FT. (7.0 m)
0 1 2 3 4
28 FT. (8.5 m) 23 FT. (7.0 m) 19 FT. (5.8 m) 17 FT. (5.2 m) 15 FT. (4.6 m)

Exhaust requirements

Do not use non-metal flexible vent, metal vent that is smaller than four inches in diameter or exhaust hoods with magnetic latches.
The dryer must be exhausted outdoors.
Do not exhaust dryer into a gas vent, chimney, wall, ceiling, or concealed space of a building.
Do not install flexible vent in enclosed walls, ceilings or floors.
If using an existing exhaust system, clean lint from entire length of exhaust system. Make sure exhaust hood is not plugged with lint.
The exhaust system should be inspected and cleaned yearly.
Replace any plastic or metal foil exhaust vent with rigid metal or flexible metal vent.
Fire Hazard
Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to do so can result in
death or fire.
WARNING
Metal flexible vent must be fully extended and supported when the dryer is in its final position. DO NOT KINK OR CRUSH THE VENT. The metal
flexible vent must be completely open to allow adequate exhaust air to flow.
Allow as much room as possible when using elbows or making turns. Bend vent gradually to avoid kinking. Remove excess flexible vent to avoid sagging and kinking that may result in reduced air flow.
Exhaust outlet is located at the center of the bottom dryer back.
The exhaust vent can be routed up, down, left, right, behind the dryer or straight out the back of the dryer.
Maximum length of exhaust system depends upon the type of vent used, number of elbows and type of exhaust hood. The maximum length for both rigid and flexible vent is shown in the chart.
Four-inch (10.2 cm) metal exhaust vent
is required. Plan installation to use the fewest number of elbows and turns.
Use 4" (10.2 cm) vent clamps to secure vent system.
better exhaust airflow
exhaust airflow
good exhaust airflow
For exhaust systems not covered by the exhaust length chart, see Whirlpool Service Manual
, “Exhausting Whirlpool Dryers,” Part No. 603197, available from your Whirlpool parts distributor.
If dryer is installed in a confined area, such as a bedroom, bathroom or closet, it must be exhausted to the outside and provision made for
enough air for combustion and ventilation. (Check governing codes and ordinances.) See “Recessed area and closet installation instructions” on Page 12.
Page 3
The console houses the electronic control board. The board is factory set for a dry time of 45 minutes. Consult the tech sheet found inside the dryer toe panel to reset dry time and for other options.
The coin-slide mechanism, control panel lock and key, and coin-box lock and key are not included and are available from usual industry sources.
IMPORTANT SETUP INFORMATION
The electronic control is factory preset to accept commands from a Palm® handheld equipped with the appropriate Whirlpool management software. If a handheld is not to be used, the handheld functionality MUST BE DISABLED as part of the control set up. Failure to disable handheld functionality may result in unauthorized machine access.
exhaust hood or sweep elbow
180°
sweep
elbow
wall
wall
roof
main exhaust vent
horizontal vent
2 ft. (61 cm) min. above
vertical vent
highest point of
building
main collector
vent
Do Not install screening or cap over
end of vent.
Gas requirements
OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Page 4
An exhaust hood should cap the outside end of the main vent to prevent exhausted air from returning to the dryers. If an exhaust hood cannot be used, the outside end of the main vent should have a sweep elbow directed downward. If the main vent travels vertically through the roof, rather than through the wall, install 180° sweep elbow on the end of vent at least 2 feet (61 cm) above the highest part of the building. The opening wall or roof shall have a diameter 1/2 inch (1.3 cm) larger than the exhaust vent diameter. The exhaust vent should be centered in the opening.
A.This installation must conform
with local codes, or in absence of local codes with the National Fuel Gas Code ANSI Z223.1/NFPA 54 or the CAN/CGA - B149* installation codes.
B.The design of this dryer has
been certified by the CSA International for use at altitudes up to 10,000 feet (3048 m) above sea level at the B.T.U. rating indicated on the model/serial plate. Burner input adjustments are not required when the dryer is operated up to this elevation. When installed above 10,000 feet (3048 m), a four percent (4%) reduction of the burner B.T.U. rating shown on the model/serial plate is required for each 1,000 foot (305 m) increase in elevation. For assistance when converting to other gas types and/or installing above 10,000 feet (3048 m) elevation, contact your local service company.
Four-inch outlet hood is preferred.
However, a 2-1/2-inch (6.4 cm) outlet exhaust hood may be used. A 2-1/2-inch (6.4 cm) outlet creates greater back pressure than other hood types. For permanent installation, a stationary exhaust system is required.
A main exhaust vent can be used for exhausting a group of dryers. Main exhaust vent should be sized to remove 200 CFM of air per dryer. Large-capacity lint screens of proper design may be used in the main exhaust vent if checked and cleaned frequently. The room where the dryers are located should have make-up air equal to or greater than the CFM of all the dryers in the room.
Back-draft Damper Kits, Part No. 3391910, are available from your Whirlpool dealer and should be installed in each dryer's exhaust vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main exhaust vent. Unobstructed air openings are required.
Each exhaust vent should enter the main vent at an angle pointing in the direction of the airflow. Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents.
The maximum angle of each vent entering the main vent should be no more than 30°.
Keep air openings free of dry cleaning fluid fumes. Fumes create acids which, when drawn through the dryer heating units, can damage dryers and loads being dried.
A clean-out cover should be located on the main exhaust vent for periodically cleaning of the exhaust system.
dryer exhaust vent
dryer exhaust vent
main collector vent
air flow
30° max.
30° max.
dryer exhaust vent
dryer exhaust vent
30° max.
An exhaust hood should cap the exhaust vent to prevent exhausted air from returning into the dryer. The outlet of the hood must be at least 12 inches (30.5 cm) from the ground or anything else that may be in the path of the exhaust.
WARNING
Explosion Hazard
Use a new AGA or CSA approved gas supply line.
Install a shut-off valve. Securely tighten all gas
connections. If connected to LP, have a
qualified person make sure gas pressure does not exceed 13" (33 cm) water column. Examples of a qualified person include licensed heating personnel, authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.

Gas Dryer

Copies of the standards listed above may be obtained from:
* National Fire Protection Association
One Batterymarch Park Quincey, Massachusetts 02269
Page 5
to dryer
shutoff valve “open” position
gas supply line
H. If local codes and ordinances
permit, it is recommended that new flexible metal tubing, design-certified by the AGA or CSA, be used for connecting the dryer to the gas supply line. (The gas feed pipe which extends through the lower rear of the dryer is provided with 3/8-inch metal pipe thread.)
I. If rigid
pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the dryer.
J. Make sure that lower edges of
the cabinet, plus the back and bottom sides of the dryer are free of obstructions to permit adequate clearance of air openings for combustion air. See "Recessed area and closet installation instructions," page 12, for minimum spacing requirements.
K. For ease of installation,
operation and servicing (if ever needed) adequate space should be provided around the dryer.
L. A 1/8-inch NPT plugged tapping,
accessible for gauge testing, must be installed immediately upstream of the gas supply connection to the dryer.
The dryer must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 psig.
The dryer must be isolated from the gas supply piping system by closing the equipment shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3,45 kPa).
Electrical requirements
C. Check that dryer is equipped
with the correct burner for the particular type of gas used. Burner information can be found on the serial/rating plate in the door well of the appliance. If this information does not agree with the type of gas available, see your dealer.
D.This dryer is equipped for use
with NATURAL GAS. It is certified by CSA International for manufactured, mixed and L.P. (propane and butane) gases with appropriate conversion. No attempt shall be made to convert the appliance from the gas specified on the serial/rating plate for use with a different gas without consulting the serving gas supplier. Conversion must be done by
a qualified service technician. Gas conversion kit part numbers are listed on the gas valve burner base.
E.Provide a rigid gas supply line of
1/2-inch IPS pipe to the dryer location. If the total length of the supply line is more than 20 feet (6.1 m), larger pipe will be needed. For L.P. gas usage, 3/8-inch, approved copper tubing may be used. Pipe-joint compounds suitable for use with L.P. gas should be used.
F. The supply line shall be equipped
with a shutoff valve installed within 6 ft. (1.8 m) of dryer in accordance with the National Fuel Gas Code, ANSI Z223.1 — latest edition*. In Canada, an individual manual shutoff valve must be installed in accordance with the B149 installation codes CAN/CGA B149.1 and CAN/CGA B149.2*. This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing. Do Not block access to the shutoff valve.
G.If the dryer is installed in a
confined area such as a bathroom or closet, provision must be made for enough air for combustion and ventilation. (Check governing codes and ordinances. or refer to the section of this instruction covering recessed and closet installations.)
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
A 120-volt, 60-Hz, AC-only, 15- or 20-ampere fused electrical supply is required. A time-delay fuse or circuit breaker is recommended.
It is recommended that a separate circuit serving only this appliance be provided.
Important: Observe all governing codes and ordinances.
3-prong ground-type outlet
3-prong ground plug
power supply cord
ground prong
Copies of the standards listed above may be obtained from:
* CSA International
8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575
** National Fire Protection Association
One Batterymarch Park Quincey, Massachusetts 02269
Electrical Shock Hazard Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions
can result in death, fire, or electrical shock.
Recommended ground method
The dryer, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70**, or the Canadian Electrical Code, CSA C22.1*.
GROUNDING INSTRUCTIONS: This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
The power supply cord plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
WARNING
6.Move dryer close to final
position. Remove cardboard or hardboard from under dryer.
8.Connect gas supply to dryer.
Use pipe-joint compound resistant to the action of L.P. gas for gas connections. If flexible metal tubing is used, be certain there are no kinks.
If necessary for service, open the toe panel, use a putty knife to press on the toe panel lock located at the center top of the toe panel. Pull downward on the toe panel to open. Toe panel is hinged at the bottom.
Note: Dryer door must be closed for dryer to operate. When door is open, dryer stops, but timer continues to run. To restart dryer, close door and push START/RESTART button.
7.Remove red cap from gas pipe.
Carefully move dryer into final position. Place level on top of the dryer, first side to side; then front to back. If the dryer is not level, adjust the legs of the dryer up or down until the dryer is level.
4.Start to screw the leveling legs
into the holes by hand. (Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs.) Use a 1-inch wrench or socket wrench to finish turning the legs until you reach the diamond mark.
Now stand the dryer up.
Slide dryer onto cardboard or hardboard before moving across floor to avoid damaging floor covering.
5.Remove the service door of the
meter case. Lift the service door up at the back and remove. Install money­accepting device. (Refer to manufaturer's instructions for proper installation.)
For dryers using coin slides, use adapter kit supplied with dryer.
Replace the meter case service door. Put the coin vault with lock and key the meter case opening.
11.To exhaust dryer, see Exhaust
requirements, Pages 3-4. Connect exhaust vent system to dryer exhaust outlet and exhaust hood using 4" (10.2 cm) clamps. Use caulking to seal exterior wall opening around exhaust hood.
12.Carefully move dryer into
final position. Place level on top of the dryer, first side to side; then front to back. If the dryer is not level, adjust the legs of the dryer up or down until the dryer is level.
13.Plug power supply cord into
grounded outlet.
14.Check dryer operation (some
accumulated time may be on the timer due to factory testing).
Insert coins in slide and press slide in slowly. (Operating time will accumulate per number of coins and type of timing cam used.) Push START/RESTART button. Using a full heat cycle (not the air cycle), let the dryer run for at least five minutes. Dryer will stop when time is used up.
10.Use a non-corrosive leak
detection fluid to check for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off gas valve controls and adjust connections. Then check connections again. Close toe panel.
All connections must be wrench­tightened.
Now Start...
Page 6
15.If the burner does not ignite
and you can feel no heat inside the dryer, shut off dryer for five minutes.
Check that all supply valve controls are in "ON" position and that the electrical cord is plugged in. Repeat five-minute test.
16.If drying time is too long,
make sure lint screen is clean.
3-prong, ground-type outlet
gas supply line
gas shutoff valve
exhaust vent
With dryer in laundry area.
1.Take tape off front corners of
dryer. Open dryer and remove the literature and parts packages. Wipe the interior of the drum thoroughly with a damp cloth.
2.Take two of the cardboard
corners from the carton and place them on the floor in back of the dryer. Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners.
3.With one of the legs in hand,
check the ridges for a diamond marking. That's how far the leg is supposed to go into the hole.
9.Open the shutoff valve in the
gas supply line.
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
WARNING
Page 7
6.Move dryer close to final
position. Remove cardboard or hardboard from under dryer.
5.Remove the service door of the
meter case. Lift the service door up at the back and remove. Install money­accepting device. (Refer to manufaturer's instructions for proper installation.)
For dryers using coin slides, use adapter kit supplied with dryer.
Replace the meter case service door. Put the coin vault with lock and key the meter case opening.
Now Start...
1.
Take tape off front corners of dryer. Open dryer and remove the literature and parts packages. Wipe the interior of the drum thoroughly with a damp cloth.
2.Take two of the cardboard
corners from the carton and place them on the floor in back of the dryer. Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners.
3.With one of the legs in hand,
check the ridges for a diamond marking. That's how far the leg is supposed to go into the hole.
4.Start to screw the leveling legs
into the holes by hand. (Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs.) Use a 1-inch wrench or socket wrench to finish turning the legs until you reach the diamond mark.
Now stand the dryer up.
Slide dryer onto cardboard or hardboard before moving across floor to avoid damaging floor covering.

Electric Dryer

Electrical requirements
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate
.
Important: Observe all governing codes and ordinances.
A four-wire or three-wire (Canada: four-wire only), single-phase, 120/240­volt, 60-Hz, AC-only electrical supply (or four-wire or three-wire, 120/208­volt, if specified on the model/serial rating plate) is required on a separate, 30-ampere circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
Recommended ground method
In U.S.:
It is the personal responsibility and obligation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70*, and all local codes and ordinances.
In Canada.:
It is the personal responsibility and obligation of the customer to install the dryer in accordance with CAN 1-B149 installation codes** and all national or local codes.
Canadian models are equipped with a four-wire, 30-amp rated flexible-type power cord. The power cord must be plugged into a mating 30-amp receptacle. (NEMA type 14-30R).
Copies of the standards listed above may be obtained from:
* National Fire Protection Association
One Batterymarch Park Quincy, Massachusetts 02269
**CSA International
8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575
exhaust vent system
fuse disconnect box
30-amp outlet
With dryer in laundry area...
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
WARNING
Page 8
3.
Assemble 3/4" U.L.-listed strain relief (U.L. marking on strain relief) into the hole below terminal block opening. Tighten strain relief screws just enough to hold the two clamp sections together. Install power supply cord/cable through the strain relief.
For a grounded, cord-connected appliance —
GROUNDING INSTRUCTIONS: This appliance must be grounded. In
the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
If using a power supply cord, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
For a permanently connected appliance —
GROUNDING INSTRUCTIONS: This appliance must be connected to
a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.
For a grounded, cord-connected appliance —
GROUNDING INSTRUCTIONS: This appliance must be grounded. In
the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Complete installation following instructions for your type of connection:
• Four-wire (recommended method)
• Three-wire (if four-wire is not
available)
1.
Disconnect the power supply.
2. Remove hold-down screw
and terminal block cover.
Power supply cord
(U.S. only)
Direct wire (U.S. only)
This dryer is manufactured with the cabinet-ground conductor connected to the NEUTRAL (center) of the wiring harness at the terminal block. If local codes do NOT permit this type of connection, use “Four­wire connection” instructions.
dryer cabinet
strain relief screws
strain relief clamp sections
Fire Hazard
Use a new UL approved 30 ampere power supply cord.
Use a UL approved strain relief. Disconnect power before making
electrical connections. Connect neutral wire (white or
center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
Fire Hazard Use 10 gauge solid copper wire. Use a UL approved strain relief. Disconnect power before making
electrical connections. Connect neutral wire (white or
center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
WARNING
WARNING
7.U.S. installations:
Make electrical connection.
Canadian installations:
Use a new UL-approved power supply cord rated 240-volt min., 30 amperes and marked for use with a clothes dryer.
WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
terminal block cover
hold­down screw
tab
external ground conductor screw
Loading...