Whirlpool ART 879/H/DBLUE Service Manual

Whirlpool ART 879/H/DBLUE Service Manual

S E R V I C E

Whirlpool Europe

Customer Services

ART 879/H/DBLUE

Service Manual

Freestanding Cooling

Combi

ART 879/H/DBLUE

Model

ART 879/H/DBLUE

 

Version

8564 879 01011

Page

 

Technical data

2

 

Spare part list

3

 

Exploded view

4

 

Circuit and Wiring diagram

5 - 6

This documentation is only intended for qualified technicians who are aware of the respec-

tive safety regulations.

 

Date: 28.07.1999

Subject to modification

Document-No.: 4812 721 14363

 

28.07.1999 / Page 2

ART 879/H/DBLUE

Whirlpool Europe

 

S E R V I C E

Doc. No: 4812 721 14363

8564 879 01011

Customer Service

 

 

 

 

 

Technical data

Dimensions

 

 

Height

202

cm

Width

59.2

cm

Depth

61.5

cm

Capacity

 

 

Total

 

 

gross

388

l

net

366

l

Cooling

 

 

gross

267

l

net

266

l

Freezing

 

 

gross

121

l

net

100

l

Electrical connection

 

 

Voltage

220 - 240

V

Frequency

50

Hz

Power consumption

 

 

in 24 hours

1.36

kWh

Freezing capacity

 

 

in 24 hours

15

kg

Compressor (cooling)

 

 

Type

EMT 32 CLP

 

Capacity (CECOMAF)

71

W

Compressor (freezing)

 

 

Type

HLY 80 AA

 

Capacity (CECOMAF)

100

W

Refrigerant (cooling)

 

 

Type

R 600 a

 

Quantity

20

g

Refrigerant (freezing)

 

 

Type

R 600 a

 

Quantity

35

g

Thermostat switching value (cooling)

 

Switch on temperature

 

 

min.

+ 4.5

˚C

Switch on temperature

 

 

max.

+ 4.5

˚C

Switch off temperature

 

 

min.

- 13.0

˚C

Switch off temperature

 

 

max.

- 26.0

˚C

Thermostat switching value (freezing)

 

Switch on temperature

 

 

min.

- 17.0

˚C

Switch on temperature

 

 

max.

- 24.5

˚C

Switch off temperature

 

 

min.

- 22.5

˚C

Switch off temperature

 

 

max.

- 30.0

˚C

Loading...
+ 4 hidden pages