S E R V I C E |
Whirlpool Europe |
Customer Services |
ART 353/G
Service Manual
Refrigerator integr.
Double Door
ART 353/G
Model |
ART 353/G |
|
Version |
8564 353 01000 |
Page |
|
Technical data |
2 |
|
Spare part list |
3 |
|
Exploded view |
4 |
|
Circuit diagram |
5 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 24.03.1997 |
Subject to modification |
Document-No.: 4812 711 15932 |
|
24.03.1997 / Page 2 |
|
|
Whirlpool Europe |
|
S E R V I C E |
||
Doc. No: 4812 711 15932 |
|
|
Customer Service |
||||
Technical data |
|
|
|
|
|
|
|
Dimensions |
|
|
Compressor (for service) |
|
|
||
|
|
|
|
||||
Height |
144.2 |
cm |
Type |
GL 60 AA |
|||
Width |
55 |
cm |
Capacity (CECOMAF) |
108 |
W |
||
Depth |
54 |
cm |
|
|
|
|
|
|
|
|
Cooling agent |
|
|
||
Capacity |
|
|
|
|
|
|
|
|
|
|
Type |
R 134 a |
|
||
Total |
|
|
Quantity |
120 |
g |
||
|
|
|
|
|
|
||
gross |
215 |
l |
Thermostat |
|
|
||
net |
214 |
l |
|
|
|
|
|
|
|
|
Switching value |
|
|
||
Cooling |
|
|
|
|
|
|
|
|
|
|
Switch on temperature |
|
|
||
gross |
166 |
l |
min. |
+ 4,5 |
˚C |
||
net |
165 |
l |
Switch on temperature |
|
|
||
|
|
|
max. |
+ 4,5 |
˚C |
||
Freezing |
|
|
Switch off temperature |
|
|
||
|
|
min. |
- 22 |
˚C |
|||
|
|
|
|||||
gross |
49 |
l |
Switch off temperature |
|
|
||
max. |
- 33 |
˚C |
|||||
net |
49 |
l |
|||||
|
|
|
|
||||
Electrical connection |
|
|
Freezing capacity |
|
|
||
|
|
|
|
|
|
||
Voltage |
220 - 240 V |
in 24 hours |
3 |
Kg |
|||
|
|
|
|
||||
Frequency |
50 |
Hz |
|
|
|
|
|
Power consumption |
|
|
|
|
|
|
|
in 24 hours |
1,04 |
kWh |
|
|
|
|
|
|
|
|
|
|
|
|