Whirlpool ARC 5250 Service Manual

SERVICE
Model ARC 5250 Version 8501 525 10002 Page
Whirlpool Europe Customer Services
ARC 5250
Service Manual
Freestanding Cooling Combi ARC 5250
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 23.03.2004 Subject to modification Document-No.: 4812 731 19382
23.03.2004 / Page 2 ARC 5250 Whirlpool Europe Doc. No: 4812 731 19382 8501 525 10002 Customer Service
Technical data
Factory Code CB 305 W
Dimensions
Height 179.0 cm Width 55.3 cm Depth 60.0 cm
Capacity
Total
gross 324 l net 300 l
Cooling
gross 208 l net 204 l
Freezing
gross 116 l net 96 l
SERVICE
Electrical connection
Voltage 220 - 240 V Frequency 50 Hz
Power consumption
in 24 hours 1.27 kWh
Freezing capacity
in 24 hours 6 kg
Compressor
Type NBT 1116 Y Capacity (CECOMAF) 146 W
Refrigerant
Type R 600 a Quantity 56 g
Thermostat switching value
Switch on temperature min. + 4.5 ˚C Switch on temperature max. + 4.5 ˚C Switch off temperature min. - 13.0 ˚C Switch off temperature max. - 26.0 ˚C