Whirlpool AKS 360/IX INSTRUCTION FOR USE

AKS 360 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids
2-5. Medium burners
3-6. Large burners
4. Small burner
7. Small burner control knob
8. Large burner control knob
9. Large burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame and star setting .
Release the knob.
If the burner does not ignite, repeat the operations described above.
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Note:
- Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
5019 519 01012
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: If the distance “A“ between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas used Type of
NATURAL GAS
(Groningue) G25
Type of gas used Appliance model Total rated
G25 25 mbar 5 gas 10.3 1141 l/h 20.6
burner
large medium small
Injector marking
129
99 78
Rated heat capacity kW
3.00
1.65
1.00
heat capacity kW
Rated consumption
332 l/h 183 l/h 111 l/h
Total rated consumption
Reduced heat capacity kW
0.60
0.35
0.35
Gas pressure (mbar)
min. rat. max.
20 25 30
Air required for burning
3
m
/h