S E R V I C E |
Whirlpool Europe |
Customer Services |
AKR 302/NB
Service Manual
Gas hob
AKR 302/NB
Model |
AKR 302/NB |
|
Version |
8578 302 10000 |
Page |
|
Technical data |
2 |
|
Spare part list |
3 |
|
Exploded view |
4 |
|
Wiring diagram |
5 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 23.09.2003 |
Subject to modification |
Document-No.: 4812 725 17555 |
|
23.09.2003 / Page 2 |
AKR 302/NB |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 725 17555 |
8578 302 10000 |
Customer Service |
||
|
|
|
|
|
Technical data
1. Removable panstand grids
2. Large burner
3-4. Medium burner
5. Small burner
6. Timer/Minute minder
7. Alphanumeric display
8. Indicator lights
9. Minute setting
10. Burner selector
Voltage: 230 V
Frequency: 50 Hz
Type |
Type of |
Injector |
Rated thermal |
Rated |
|
Reducedheat |
|
Gas pressure |
||||||
of gas used |
burner |
marking |
flow rate (kW) |
consumption |
|
capacity (kW) |
|
|
(mbar) |
|
||||
|
|
|
|
|
|
|
|
|
|
|
min. |
rat. |
max. |
|
Natural gas |
large |
128 |
3,00 |
286 l/h |
|
0,60 |
|
|
|
|
||||
(Methane) |
medium |
94 |
1,65 |
157 l/h |
|
0,35 |
17 |
20 |
25 |
|||||
G20 |
|
small |
76 |
1,00 |
95 l/h |
|
0,30 |
|
|
|
|
|||
LPG |
|
large |
85 |
3,00 |
218 g/h |
|
0,60 |
|
|
|
|
|||
(Cylinder) |
medium |
65 |
1,65 |
120 g/h |
|
0,35 |
20 |
28-30 |
35 |
|||||
G30 |
|
small |
50 |
1,00 |
73 g/h |
|
0,30 |
|
|
|
|
|||
LPG |
|
large |
85 |
3,00 |
214 g/h |
|
0,60 |
|
|
|
|
|||
(Cylinder) |
medium |
65 |
1,65 |
118 g/h |
|
0,35 |
25 |
37 |
45 |
|||||
G31 |
|
small |
50 |
1,00 |
71 g/h |
|
0,30 |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||||||
Type of gas used |
|
Appliance |
|
Total rated heat |
|
Total rated |
|
Air required for |
||||||
|
|
|
|
model |
|
capacity (kW) |
|
consumption |
|
burning (m3 /h) |
||||
G20 |
20 mbar |
|
|
4G |
|
7,30 |
|
|
695 l/h |
|
|
14,6 |
|
|
G30 |
28-30 mbar |
|
4G |
|
7,30 |
|
|
531 g/h |
|
|
14,6 |
|
||
G31 |
37 mbar |
|
|
4G |
|
7,30 |
|
|
521 g/h |
|
|
14,6 |
|
Failure codes
Fault |
Defect |
Repair |
|
|
|
F01 |
Overheating of the PCB. |
Check temperature |
|
|
|
F02 |
No initial change in voltage from the |
Check/Replace thermocouple |
|
thermocouple in 10 seconds. |
|
F03 |
Internal PCB failure |
Check/Replace PCB |
|
|
|