Whirlpool AKP 634 WH, AWE 87612, AKM 432/NB/01, AKP 634 JA, AWE 88612 INSTRUCTION FOR USE

...
AKM 432 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids
2. Large burner
3. Rapid electric hotplate 4-5. Medium burners
6. Large burner control knob
7. Medium burner control knob
8. Medium burner control knob
9. Electric hotplate control knob
10. Pilot lamp for electric hotplate
Symbols
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burner ignites.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electronic ignition
Minimum opening or reduced delivery
Operation of the electric hotplate
Set the knob to one of positions 1-6, which correspond to different temperatures.
To switch off the hotplate, set the knob to position “0”.
Important
Improper use of the grids can result in damage to the hob: do not position the grids upside down or slide them across the hob.
Do not use:
cast iron griddles or terracotta pots and pans heat diffusers such as metal mesh, or any
other types
two burners simultaneously for one
receptacle (e.g. fish kettle).
5019 319 61651
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: if the distance “A“ between the wall cabinets is between 660 mm and 680 mm, the
height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G 20 NATURAL
GAS (Groningue) G 25
LIQUID PETROLEUM GAS
(Cylinder) G 30 LIQUID
PETROLEUM GAS (Cylinder) G 31
Type of gas used Appliance model Total rated
G 20 20 mbar 3 gas + 1 E 6.30 600 l/h 12.6 G 25 25 mbar 3 gas + 1 E 5.84 648 l/h 11.7 G 30 28-30 mbar 3 gas + 1 E 6.30 458 g/h 12.6 G 31 37 mbar 3 gas + 1 E 6.30 450 g/h 12.6
burner
large medium
large medium
large medium
large medium
ELECTRIC HOTPLATE POWER: 1500 W.
Injector marking
128
94
128
94
85 65
85 65
Rated heat capacity Pcs-kW
3.00
1.65
2.78
1.53
3.00
1.65
3.00
1.65
heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
308 l/h 170 l/h
218 g/h 120 g/h
214 g/h 118 g/h
Total rated consumption
Reduced heat capacity Pcs-kW
0.60
0.35
0.60
0.35
0.60
0.35
0.60
0.35
Gas pressure
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for burning
3
m
/h
Loading...