AKM 432 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids
2. Large burner
3. Rapid electric hotplate
4-5. Medium burners
6. Large burner control knob
7. Medium burner control knob
8. Medium burner control knob
9. Electric hotplate control knob
10. Pilot lamp for electric hotplate
Symbols
Operation of burners with electric
ignition
To light one of the burners:
• Press the relative knob and turn it
anti-clockwise to the large flame and star
setting .
• At the same time, keep the knob pressed against
the control panel until the burner ignites.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
— Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
Shaded
circle
Large
flame and
star
Small flame
Tap closed
Maximum opening/delivery
and electronic ignition
Minimum opening or
reduced delivery
Operation of the electric hotplate
• Set the knob to one of positions 1-6, which
correspond to different temperatures.
• To switch off the hotplate, set the knob to
position “0”.
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
— cast iron griddles or terracotta pots and pans
— heat diffusers such as metal mesh, or any
other types
— two burners simultaneously for one
receptacle (e.g. fish kettle).
5019 319 61651
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: if the distance “A“ between the wall cabinets is between 660 mm and 680 mm, the
height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL
GAS
(Methane) G 20
NATURAL
GAS
(Groningue) G 25
LIQUID
PETROLEUM GAS
(Cylinder) G 30
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Type of gas used Appliance model Total rated
G 20 20 mbar 3 gas + 1 E 6.30 600 l/h 12.6
G 25 25 mbar 3 gas + 1 E 5.84 648 l/h 11.7
G 30 28-30 mbar 3 gas + 1 E 6.30 458 g/h 12.6
G 31 37 mbar 3 gas + 1 E 6.30 450 g/h 12.6
burner
large
medium
large
medium
large
medium
large
medium
ELECTRIC HOTPLATE POWER: 1500 W.
Injector
marking
128
94
128
94
85
65
85
65
Rated heat
capacity
Pcs-kW
3.00
1.65
2.78
1.53
3.00
1.65
3.00
1.65
heat capacity
Pcs-kW
Rated
consumption
286 l/h
157 l/h
308 l/h
170 l/h
218 g/h
120 g/h
214 g/h
118 g/h
Total rated
consumption
Reduced
heat capacity
Pcs-kW
0.60
0.35
0.60
0.35
0.60
0.35
0.60
0.35
Gas pressure
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required
for burning
3
m
/h