AKM 546 PRODUCT DESCRIPTION SHEET
IT GB
Removable panstand grids
1.
Large burner
2.
Medium burners
3-4.
Small burner
5.
Medium burner control knob
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, keep the knob pressed
against the control panel until the burners
ignites.
• After the burner has ignited, keep the knob
pressed for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Shaded
circle
Large
flame
and star
Small
flame
Tap close d
Maximum opening/delivery
and electric ignition
Minimum opening or
reduced delivery
Note:
Should particular local conditions of the
—
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
The safety device of the burner shuts off the
—
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.).
5019 319 01459
DIMENSIONS OF COOKING HOB AND WORKTOP
Note: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Ty p e o f g as
used
NATURAL GAS
(Methane) G20
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31
Ty p e of
burner
large
medium
small
large
medium
small
large
medium
small
Injector
marking
Y 115
H2 98
X 72
87
65
50
87
65
50
Rated
heat
capacity
kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Ty p e o f g as us ed
G20 20 mbar 4 gas 7.30 695 l/h 9,52
G30 28-30 mbar 4 gas 7.30 531 g/h 30,94
G31 37 mbar 4 gas 7.30 521 g/h 23,80
Appliance
model
Total rated heat
capacity
kW
Total rated
consumption
Air required
for burning
m
ELECTRIC SUPPLY: 230 V ~ 50 Hz
3
/h