AKM 447 |
IT GB |
PRODUCT DESCRIPTION SHEET |
Operation of burners with electric ignition
To light one of the burners:
•Press the relative knob and turn it anti-
clockwise to the large flame and star setting .
•At the same time, keep the knob pressed against the control panel until the burner ignites.
•Release the knob.
•After the burner has ignited, keep the knob pressed for about 10 seconds.
If the burner does not ignite, repeat the operations described above.
1.Removable panstand grids
2-5. Medium burners
3-6. Large burners
4.Small burner
7. Small burner control knob
8. Large burner control knob
9. Large burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Shaded |
Tap closed |
|
circle |
||
|
||
Large |
Maximum opening/delivery |
|
flame |
||
and electric ignition |
||
and star |
||
|
||
Small |
Minimum opening or |
|
flame |
reduced delivery |
Note:
-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation
with the knob turned to the small flame setting .
-The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc).
5019 319 01457
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: if the distance “A” between the wall cabinets is between 600 mm and 680 mm, the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE |
|
|
|
|
|
|
|
|
|
CATEGORY II2H3+ |
|||||
Type of gas used |
|
Type of |
Injector |
Rated heat |
Rated |
|
Reduced |
Gas pressure |
|||||||
|
|
|
burner |
marking |
capacity |
consumption |
|
heat |
|
|
mbar |
|
|||
|
|
|
|
|
|
kW |
|
|
|
capacity |
|
|
|
||
|
|
|
|
|
|
|
|
|
min. |
rat. |
max. |
||||
|
|
|
|
|
|
|
|
|
|
kW |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
|
large |
Y 115 |
3.00 |
|
286 l/h |
|
0.60 |
|
|
|
|
|||
|
medium |
H2 98 |
1.65 |
|
157 l/h |
|
0.35 |
|
17 |
20 |
25 |
||||
(Methane) |
G 20 |
|
|
|
|
||||||||||
|
small |
X 72 |
1.00 |
|
95 l/h |
|
0.30 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID PETROLEUM |
large |
87 |
|
3.00 |
218 g/h |
|
0.60 |
|
|
|
|
||||
GAS |
|
|
medium |
65 |
|
1.65 |
120 g/h |
|
0.35 |
|
20 |
28-30 |
35 |
||
(Cylinder) |
G 30 |
|
small |
50 |
|
1.00 |
|
73 g/h |
|
0.30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID PETROLEUM |
large |
87 |
3.00 |
214 g/h |
|
0.60 |
|
|
|
|
|||||
GAS |
|
|
medium |
65 |
1.65 |
118 g/h |
|
0.35 |
|
25 |
37 |
45 |
|||
(Cylinder) |
G 31 |
|
small |
50 |
1.00 |
|
71 g/h |
|
0.30 |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Type of gas used |
Appliance model |
Total rated |
|
Total rated |
|
|
Air necessary (m3) for the |
||||||||
|
|
|
|
|
heat capacity |
|
consumption |
|
combustion of 1 m3 of gas |
||||||
|
|
|
|
|
kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
G 20 20 mbar |
5 gas |
|
10.30 |
|
981 l/h |
|
|
9.52 |
|
|
|
||||
G 30 28-30 mbar |
5 gas |
|
10.30 |
|
749 g/h |
|
|
30.94 |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
||||
G 31 37 mbar |
5 gas |
|
10.30 |
|
735 g/h |
|
|
23.80 |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ELECTRIC SUPPLY: 230 V ~ 50 Hz