Whirlpool AKM 441/GR INSTRUCTION FOR USE

AKM 441 PRODUCT DESCRIPTION SHEET
ES PT IT GR GB
1.
Removable panstand grids
2.
Large burner
3-4.
Medium burners
5.
Small burner
6.
Large burner control knob
7.
Medium burner control knob
8.
Medium burner control knob
9.
Small burner control knob
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it
anti-clockwise to the large flame and star
At the same time, keep the knob pressed against
the control panel until the burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc,).
5019 319 53911
Shaded
circle
Large flame
and star
Small
flame
Important:
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
Cast iron griddles or terracotta pots and pans.
Heat diffusers such as metal mesh, or any
other types.
Two burners simultaneously for one
receptacle (e.g. fish kettle).
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening
or reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance A between the wall cabinets is between 600 mm and 680 mm, the
height B must be a minimum of 520 mm.
If the distance A between the wall cabinets is greater than the width of the
cooktop, the height B must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS
(Methane) G20
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 14.6
G30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G31 37 mbar 4 gas 7.30 521 g/h 14.6
ELECTRIC SUPPLY: 230 V 50 Hz
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
100/mm
128
94
76
85
65
50
85
65
50
Rated
heat
capacity
kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat
capacity kW
Rated
consumption
218 g/h
120 g/h
214 g/h
118 g/h
286 l/h
157 l/h
95 l/h
73 g/h
71 g/h
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated
consumption
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Gas pressure
mbar
Air required
for burning
m3/h
5019 319 53911